These Listings were Last Updated on Friday, November 20, 2009 at 4:15 AM Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions. |
|
Warning: NSF is concerned about fraudulent downloading and manipulation of website text. If you have received this listing in hard copy, always confirm this certification/listing information by going directly to http://www.nsf.org/Certified/Biosafety/Listings.asp? for the latest most accurate information. |
| Cabinet Style A = Bench Unit With Base or Adjustable Legs Provided B = Bench Unit Without Base or Adjustable Legs Provided C = Console |
Window Type H = Hinged S = Sliding F = Fixed |
Bench Height NA = Not Applicable NP = Not Provided |
CBV = Concurrent Balance Value
Due to a change in nomenclature in NSF/ANSI 49 - 2002 “Class II (Laminar Flow) Biosafety Cabinetry,” Class II, Type A cabinets are now referred to as Class II, Type A1 and Class II, Types B3 and A/B3 cabinets as Class II, Type A2. Class II, Types B1 and B2 cabinets remain unchanged.
| ALLENTOWN, INC. | ![]() |
| ROUTE 526 | |
| P.O. BOX 698 | |
| ALLENTOWN, NJ 08501-0698 | |
| 609-259-7951 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 34850 Safety Cabinet[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | Casters I.V. Pole U.V. Light |
| 34860 Safety Cabinet[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | Casters I.V. Pole U.V. Light |
[1] The first four digits of the serial number refer to date of manufacture.
[2] Beginning with serial number 070570504. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set-point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
[3] Beginning with serial number 070570502. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set-point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
|
|||||||||
| BAKER COMPANY, INC. (THE) | |
| SANFORD AIRPORT | |
| P.O. DRAWER E | |
| SANFORD, ME 04073 | |
| 800-992-2537 | |
| 207-324-8773 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| NCB-D4[1] [2] | B1 | C | 100 - 110 | 80 - 90 70 - 80 |
437 @ 1.5 | 4 | 12S | NA | I.V. Pole U.V. Light |
| NCB-D4[1] [3] | B1 | C | 100 - 110 | 63 - 73 55 - 65 |
295 @ 0.8 | 4 | 8S | NA | I.V. Pole U.V. Light |
| NCB-D6[1] [4] | B1 | C | 100 - 110 | 80 - 90 70 - 80 |
666 @ 1.8 | 6 | 12S | NA | I.V. Pole U.V. Light |
| NCB-D6[1] [5] | B1 | C | 100 - 110 | 63 - 73 55 - 65 |
463 @ 0.9 | 6 | 8S | NA | I.V. Pole U.V. Light |
| SG 403A[1] [6] | A2 | A | 100 - 110 | 50 - 60 45 - 55 |
N/A | 4 | 8S | 37 | U.V. Light I.V. Pole Armrest Casters |
| SG 403A[1] [7] | A2 | A | 100 - 110 | 53 - 63 45 - 55 |
N/A | 4 | 10S | 37 | U.V. Light I.V. Pole Armrest Casters |
| SG 403A HE[1] [8] | A2 | A | 100 - 110 | 45 - 55 42 - 52 |
N/A | 4 | 8S | 37 | I.V. Pole U.V. Light |
| SG 403A HE[1] [9] | A2 | A | 100 - 110 | 47 - 57 40 - 50 |
N/A | 4 | 10S | 37 | I.V. Pole U.V. Light |
| SG 403A TX[1] [10] | B2 | A | 100 - 110 | 52 - 62 47 - 57 |
860 @ 1.7 | 4 | 8S | 37 | I.V. Pole U.V. Light |
| SG 503A HE[1] [11] | A2 | A | 100 - 110 | 53 - 63 46 - 56 |
N/A | 5 | 12S | 37 | Casters I.V. Pole U.V. Light |
| SG 503A HE[1] [12] | A2 | A | 100 - 110 | 50 - 60 48 - 58 |
N/A | 5 | 8S | 37 | Casters I.V. Pole U.V. Light |
| SG 603A[1] [13] | A2 | A | 100 - 110 | 50 - 60 47 - 57 |
N/A | 6 | 10S | 37 | U.V. Light I.V. Pole Casters |
| SG 603A[1] [13] | A2 | A | 100 - 110 | 50 - 60 47 - 57 |
N/A | 6 | 8S | 37 | U.V. Light I.V. Pole Casters |
| SG 603A HE[1] [14] | A2 | A | 100 - 110 | 47 - 57 40 - 50 |
N/A | 6 | 10S | 37 | I.V. Pole U.V. Light |
| SG 603A HE[1] [14] | A2 | A | 100 - 110 | 47 - 57 40 - 50 |
N/A | 6 | 8S | 37 | I.V. Pole U.V. Light |
| SG 603A TX[1] [15] | B2 | A | 100 - 110 | 45 - 55 43 - 53 |
1150 @ 2.0 | 6 | 8S | 37 | I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate calculated method with thermal anemometer in a constricted (3 inch high)
access opening (consult manufacturer's operator's manual for appropriate correction
factor, if applicable).
[2] Beginning with serial number 87770. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 75-85 fpm. The
acceptable non-uniform downflow ranges beginning with zone 1 at the rear of the work
area and ending with zone 2 behind the front window are 80-90 fpm (zone 1 - comprised of
lateral rear and center rows) and 70-80 fpm (zone 2 - comprised of the front lateral
row). Uniform and non-uniform nominal set-points were established with I.V. Pole and
U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2004. This cabinet
qualifies only with the armrest installed.
[3] Beginning with serial number 87770. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 60-70 fpm. The
acceptable non-uniform downflow ranges beginning with zone 1 at the rear of the work
area and ending with zone 2 behind the front window are 63-73 fpm (zone 1 - comprised of
lateral rear and center rows) and 55-65 fpm (zone 2 - comprised of the front lateral
row). Uniform and non-uniform nominal set-points were established with the I.V. Pole
and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2004. This
cabinet qualifies only with the armrest installed.
[4] Beginning with serial number 84960. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 75-85 fpm. The
acceptable non-uniform downflow ranges beginning with zone 1 at the rear of the work
area and ending with the zone 2 behind the front window are 80-90 fpm (zone 1 -
comprised of lateral rear and center rows) and 70-80 fpm (zone 2 comprised of the front
lateral row). Uniform and non-uniform nominal set-points were established with I.V.
Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2004.
This cabinet qualifies only with the armrest installed.
[5] Beginning with serial number 84960. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 60 - 70 fpm.
The acceptable non-uniform downflow ranges beginning with zone 1 at the rear of the work
area and ending with zone 2 behind the front window are 63-73 fpm (zone 1 - comprised of
lateral rear and center rows) and 55-65 fpm (zone 2 - comprised of the front lateral
row). Uniform and non-uniform nominal set-points were established with the I.V. Pole
and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2004. This
cabinet qualifies only with the armrest installed.
[6] Beginning with serial number 78977. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 50-60 fpm. The
acceptable non-uniform downflow ranges listed above begins with zone 1 (50-60 fpm) at
the rear of the work area (comprised of lateral rear and center rows) and ending with
zone 2 (45-55 fpm) (comprised of front lateral row) behind the front window enclosing
the work area. Downflow nominal set points were established with the I.V. Pole and U.V.
Light removed.
[7] Beginning with serial number 78977. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 50-60 fpm. The
acceptable non-uniform downflow ranges listed above begins with zone 1 (53-63 fpm) at
the rear of the work area (comprised of lateral rear and center rows) and ending with
zone 2 (45-55 fpm) (comprised of front lateral row) behind the front window enclosing
the work area. Downflow nominal set points were established with the I.V. Pole and U.V.
Light removed.
[8] Beginning with serial number 93621. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 45-55 fpm. The
acceptable non-uniform downflow ranges listed above begin with zone 1 (45-55 fpm) at the
rear of the work area (compromised of lateral rear and center rows) and end with zone 2
(42-52 fpm) (comprised of front lateral row) behind the front window enclosing the work
area. Downflow nominal set points were established with the I.V. Pole and U.V. Light
removed. This cabinet model was Certified to NSF/ANSI 49-2007. This cabinet qualifies
only with the armrest installed. Cabinet model number suffixes SP and HE INT are
Certified for alternate motor/blower combinations and input power supply.
[9] Beginning with serial number 93621. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 45-55 fpm. The
acceptable non-uniform downflow ranges listed above begin with zone 1 (47-57 fpm) at the
rear of the work area (compromised of lateral rear and center rows) and end with zone 2
(40-50 fpm) (comprised of front lateral row) behind the front window enclosing the work
area. Downflow nominal set points were established with the I.V. Pole and U.V. Light
removed. This cabinet model was Certified to NSF/ANSI 49-2007. This cabinet qualifies
only with the armrest installed. Cabinet model number suffixes SP and HE INT are
Certified for alternate motor/blower combinations and input power supply.
[10] Beginning with serial number 89049. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 50-60 fpm. The
acceptable non-uniform downflow ranges begin with zone 1 (52-62 fpm) at the rear of the
work area (comprised of lateral rear and center rows) and end with zone 2 (47-57 fpm)
(comprised of front lateral row) behind the front window enclosing the work area.
Downflow nominal set points were established with the I.V. Pole and U.V. Light removed.
This cabinet model was Certified to NSF/ANSI 49-2004. This cabinet qualifies only with
the armrest installed. This model was tested with the supply blower inlet prefilter
installed. Cabinet model number suffix INT is Certified for alternate motor/blower
combinations and inlet power supply.
[11] Beginning with serial number 90883. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 50-60 fpm. The
acceptable non-uniform downflow ranges listed above begins with zone 1 (53-63 fpm) at
the rear of the work area (comprised of lateral rear and center rows) and ending with
zone 2 (46-56 fpm) (comprised of front lateral row) behind the front window enclosing
the work area. Downflow nominal set points were established with the I.V. Pole and U.V.
Light removed. This cabinet model was certified to NSF/ANSI 49-2007. This cabinet
qualifies only with the armrest installed. This model was certified with optional
workarea prefilters installed. ATS autolift with casters is an additional acceptable
option. Cabinet model number suffixes SP and HE INT are certified for alternate motor /
blower combinations and input power supply.
[12] Beginning with serial number 90883. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 50-60 fpm. The
acceptable non-uniform downflow ranges listed above begins with zone 1 (50-60 fpm) at
the rear of the work area (comprised of lateral rear and center rows) and ending with
zone 2 (48-58 fpm) (comprised of front lateral row) behind the front window enclosing
the work area. Downflow nominal set points were established with the I.V. Pole and U.V.
Light removed. This cabinet model was certified to NSF/ANSI 49-2007. This cabinet
qualifies only with the armrest installed. This model was certified with optional
workarea prefilters installed. ATS autolift with casters is an additional acceptable
option. Cabinet model number suffixes SP and HE INT are certified for alternate motor /
blower combinations and input power supply.
[13] Beginning with serial number 80047. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 50-60 fpm. The
acceptable non-uniform downflow ranges listed above begins with zone 1 (50-60 fpm) at
the rear of the work area (comprised of lateral rear and center rows) and ending with
zone 2 (47-57 fpm) (comprised of front lateral row) behind the front window enclosing
the work area. Downflow nominal set points were established with the I.V. Pole and U.V.
Light removed. This cabinet qualifies only with the armrest installed.
[14] Beginning with serial number 93808. This model qualifies for both uniform and
non-uniform (zoned) downflow. The acceptable uniform downflow range is 45-55 fpm. The
acceptable non-uniform downflow ranges listed above begin with zone 1 (47-57 fpm) at the
rear of the work area (comprised of lateral rear and center rows) and end with zone 2
(40-50 fpm) (comprised of front lateral row) behind the front window encnet qualifies
only with the armrest installed. This model was tested with the supply blower inlet
prefilter installed.
|
|||||||||
| CHC LAB | |
| 520-1 YOUNGSAN-DONG | |
| YUSUNG-GU | |
| DAEJEON 305-500 | |
| KOREA, REPUBLIC OF | |
| 82 42 933 0036 |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| CHC-777A2-03[1] [2] | A2 | A | 100 - 110 | 65 - 75 | N/A | 3 | 8S | 33 | Casters I.V. Pole U.V. Light |
| CHC-777A2-04[1] [2] | A2 | A | 100 - 110 | 65 - 75 | N/A | 4 | 8S | 33 | Casters I.V. Pole U.V. Light |
| CHC-777A2-06[1] [3] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 8S | 33 | Casters I.V. Pole U.V. Light |
[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's alternate
method with thermal anemometer in a constricted (3 inch high) access opening (consult
manufacturer's operator's manual for appropriate correction factor). Downflow nominal
set point was established with the U.V. Light removed. This cabinet model was Certified
to NSF/ANSI 49-2007. This cabinet qualifies only with the armrest installed.
[2] Certified for use with power supplies of 115V/60 Hz, 220V/50 Hz, and 220V/60 Hz.
[3] Certified for use with power supplies of 115V/60 Hz and 220V/60 Hz.
|
|||||||||
| DALTON CORPORATION | |
| 9 ICHIGAYA SANAI-CHO, SHINJUKU-KU | |
| TOKYO, 162-0846 | |
| JAPAN | |
| 813 3267 2111 |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| NSC-11A/B3-1200[1] | A2 | A | 100 - 110 | 65 - 75 | N/A | 4 | 8S | 32 | U.V. Light I.V. Pole |
[1] Beginning with series 20 and higher. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding inflow nominal
set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
recommended alternate method with thermal anemometer in a constricted (3 inch high)
access opening (consult manufacturer's operator manual for appropriate correction
factor, if applicable), without adjusting cabinet airflow balance. Downflow nominal
set-point of 70 fpm was established in the plane of the window with the I.V. Pole
removed and U.V. Light installed. This cabinet qualifies only with the armrest
installed. This cabinet was tested and Certified with a power supply of 100V and 50Hz.
A corrected downflow nominal set-point of 72 fpm was established 4 inches above the
plane of the window per NSF/ANSI 49-2002, with the I.V. Pole and U.V. Light removed.
|
|||||||||
| ENVIRCO CORPORATION | |
| 101 MCNEILL ROAD | |
| SANFORD, NC 27330 | |
| 919-775-2201 |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 10448 EBC 47[1] | A2 | B | 100 - 110 | 67 - 77 67 - 77 80 - 90 74 - 84 |
N/A | 4 | 8H | 32 | None |
| 10451 EBC 70[2] | A2 | A | 100 - 110 | 68 - 78 56 - 66 |
N/A | 6 | 8H | 32 | I.V. Pole |
[1] Beginning with serial number 20106022. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding nominal set-point
of 120 fpm was confirmed using the manufacturer's recommended alternate method with
thermal anemometer above the exhaust filter without adjusting cabinet airflow balance.
This model option qualifies for both uniform and non-uniform (zoned) downflow. The
acceptable uniform downflow range is 72 - 82 fpm. The acceptable non-uniform downflow
ranges listed above begin with Zone 1 at the rear of the work area and end with Zone 4
behind the window enclosing the work area. The zone grids are lateral (side-to-side).
[2] Beginning with serial number 20212001. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding nominal set-point
of 120 fpm was confirmed using the manufacturer's recommended alternate method with
thermal anemometer above the exhaust filter without adjusting cabinet airflow balance.
This model option qualifies for both uniform and non-uniform (zoned) downflow. The
acceptable uniform downflow range is 65 - 75 fpm (grid comprised of 4 lateral rows).
The acceptable non-uniform downflow ranges listed above begin with Zone 1 at the rear of
the work area (grid comprised of 3 lateral rows) and end with Zone 2 at the front of the
work area (grid comprised of a single lateral row behind the window enclosing the work
area).
|
|||||||||
| ESCO MICRO PTE LTD (BIOTECH EQUIPMENT DIVISION) | |
| 21 CHANGI SOUTH STREET 1 | |
| 486777 | |
| SINGAPORE | |
| 65 65420833 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| LA2 4A2[1] | A2 | A | 100 - 110 | 65 - 75 | N/A | 4 | 9S | 34 | I.V. Pole U.V. Light |
| LA2 5A2[5] | A2 | A | 100 - 110 | 65 - 75 | N/A | 5 | 9S | 36 | I.V. Pole U.V. Light |
| LA2 6A2[2] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 8S | 35 | I.V. Pole U.V. Light |
| LB2 4B2[3] | B2 | A | 100 - 110 | 65 - 75 | 810 @ 1.9 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| LB2 6B2[4] | B2 | A | 100 - 110 | 65 - 75 | 1218 @ 2.2 | 6 | 8S | 36 | I.V. Pole U.V. Light |
| LR2 4S2[6] | A2 | A | 100 - 110 | 65 - 75 | N/A | 4 | 10S | 35 | I.V. Pole U.V. Light |
| LR2 6S2[7] | A2 | A | 100 - 110 | 60 - 70 | N/A | 6 | 8S | 35 | I.V. Pole U.V. Light |
[1] Beginning with serial number 2004-7329. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 70 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
[2] Beginning with serial number 2004-8113. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
[3] Beginning with serial number 2005-10005. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 70 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
[4] Beginning with serial number 2005-9857. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 70 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
[5] Beginning with serial number 2006-14526. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 70 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
[6] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. This nominal set point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set point of 70 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2007.
[7] Beginning with serial number 2008-28898. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2007.
|
|||||||||
| FISHER SCIENTIFIC | |
| 112 COLONADE ROAD | |
| OTTAWA, ONTARIO K2E 7L6 | |
| CANADA | |
| 613-228-6285 |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 361004616[2] [3] | A2 | A | 100 - 110 | 61 - 71 | N/A | 4 | 10H | 27 | I.V. Pole U.V. Light |
| 361004617[1] [3] | A2 | A | 100 - 110 | 61 - 71 | N/A | 6 | 10H | 27 | I.V. Pole U.V. Light |
| 361004618[2] [3] | A2 | B | 100 - 110 | 61 - 71 | N/A | 4 | 10H | NA | I.V. Pole U.V. Light |
| 361004619[1] [3] | A2 | B | 100 - 110 | 61 - 71 | N/A | 6 | 10H | NA | I.V. Pole U.V. Light |
| 361004620[2] | A2 | A | 100 - 110 | 61 - 71 | N/A | 4 | 10H | 27 | I.V. Pole U.V. Light |
| 361004621[1] | A2 | A | 100 - 110 | 61 - 71 | N/A | 6 | 10H | 27 | I.V. Pole U.V. Light |
| 361004622[2] | A2 | B | 100 - 110 | 61 - 71 | N/A | 4 | 10H | NA | I.V. Pole U.V. Light |
| 361004623[1] | A2 | B | 100 - 110 | 61 - 71 | N/A | 6 | 10H | NA | I.V. Pole U.V. Light |
[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding nominal set-point of 118 fpm was confirmed using
manufacturer's recommended alternate method with thermal anemometer above exhaust filter
without adjusting cabinet airflow balance. Downflow nominal set-point of 66 fpm was
established with U.V. Light and I.V. Pole installed.
[2] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding nominal set-point of 122 fpm was confirmed using the
manufacturer's recommended alternate method with thermal anemometer above exhaust filter
without adjusting cabinet airflow balance. Downflow nominal set-point of 66 fpm was
established with U.V. Light and I.V. Pole installed.
[3] This model has an A2 type design clasification.
|
|||||||||
| GERMFREE LABORATORIES, INC. | |
| 11 AVIATOR WAY | |
| ORMOND BEACH, FL 32174 | |
| 800-888-5357 | |
| 386-677-7742 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| BTE-4[2] | B2 | A | 102 - 112 | 70 - 80 | 685 @ 3.6 | 4 | 8H | NA | None |
| BTE-6[1] | B2 | A | 102 - 112 | 70 - 80 | 1078 @ 2.8 | 6 | 8H | NA | None |
[1] Beginning with serial number 6s-15-BT-11214. Inflow nominal set point of 107 fpm was
established with a direct airflow reading instrument (DIM). A corresponding inflow
velocity nominal set point of 114 fpm was confirmed using the manufacturer's recommended
secondary (alternate) method with thermal anemometer in work area for supply air volume
determination (Annex A, sec.X.C.4.d) and pitot tube in exhaust duct for cabinet total
exhaust air volume determination, without adjusting cabinet airflow balance. Resultant
inflow velocity determined by calculation. This cabinet model was Certified to NSF/ANSI
49 - 2004.
[2] Beginning with serial number 4s-15-BT-11409. Inflow nominal set point of 107 fpm was
established with a direct airflow reading instrument (DIM). This inflow velocity nominal
set point was confirmed using the manufacturer's recommended secondary (alternate)
method with thermal anemometer in work area for supply air volume determination (Annex
A, sec.X.C.4.d) and pitot tube in exhaust duct for cabinet total exhaust air volume
determination, without adjusting cabinet airflow balance. Resultant inflow velocity
determined by calculation. This cabinet model was Certified to NSF/ANSI 49 - 2004.
|
|||||||||
| LABCONCO CORPORATION | ![]() |
| 8811 PROSPECT | |
| KANSAS CITY, MO 64132 | |
| 816-333-8811 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 34300 Logic Series[1] [2] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 10S | 36 | I.V. Pole U.V. Light Casters |
| 34308 Logic Series[1] [3] | A2 | A | 100 - 110 | 50 - 60 | N/A | 3 | 8S | 36 | I.V. Pole U.V. Light Casters |
| 34400 Logic Series[2] [4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | Casters I.V. Pole U.V. Light |
| 34408 Logic Series[3] [4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 8S | 36 | Casters I.V. Pole U.V. Light |
| 34410 Logic Series[3] [4] | B2 | A | 100 - 110 | 50 - 60 | 810 @ 1.9 | 4 | 8S | 36 | I.V. Pole U.V. Light |
| 34500 Logic Series[2] [5] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 10S | 36 | Casters I.V. Pole U.V. Light |
| 34508 Logic Series[3] [5] | A2 | A | 100 - 110 | 50 - 60 | N/A | 5 | 8S | 36 | Casters I.V. Pole U.V. Light |
| 34600 Logic Series[2] [6] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | Casters I.V. Pole U.V. Light |
| 34608 Logic Series[3] [6] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 8S | 36 | Casters I.V. Pole U.V. Light |
| 34610 Logic Series[3] [7] | B2 | A | 100 - 110 | 50 - 60 | 1218 @ 2.2 | 6 | 8S | 36 | Bag-In/Bag-Out I.V. Pole U.V. Light |
| 34800 PuriCare Series[1] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S | 36 | I.V. Pole U.V. Light |
| 34810 PuriCare Series[4] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S | 36 | I.V. Pole U.V. Light |
[1] Beginning with serial number 070570504. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set-point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
[2] Certified for use with power supplies of 230V/50 Hz and 230V/60 Hz.
[3] Certified for use with power supplies of 100V/50 Hz, 100V/60 Hz, 230V/50 Hz, and 230V/60
Hz.
[4] Beginning with serial number 070570502. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set-point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
[5] Beginning with serial number 070570511. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (2.25 inch high) access opening (consult manufacturer's operator manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set-point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2007.
[6] Beginning with serial number 070570503. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (4.25 inch high) access opening (consult manufacturer's operator manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set-point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
[7] Beginning with serial number 070900000. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (4.25 inch high) access opening (consult manufacturer's operator manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nomial set-point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was certified to NSF/ANSI 49-2007.
|
|||||||||
NOTE: Bench stand models 3730300, 3730310, 3780200 and 3780100 may be used with cabinet models
34300/34308 Logic Series.
Bench stand models 3730400, 3730410, 3780201 and 3780101 may be used with cabinet models
34400/34408 Logic Series and the 34800 PuriCare Series.
Bench stand models 3730500, 3730510, 3780203, 3780106, 3780107, 3780312, and 3780316 may
be used with cabinet models 34500/34508 Logic Series.
Bench stand models 3730600, 3630610, 3780202 and 3780102 may be used with cabinet models
34600/34608 Logic Series and the 34810 PuriCare Series.
Bench stand model 3730400 may also be used with cabinet models 34410 Logic Series.
All bench stand models beginning with 378 may be used with or without the optional wheel
kit (PN# 3784000).
| MICROZONE CORPORATION | |
| 86 HARRY DOUGLAS DRIVE | |
| OTTAWA, ONTARIO K2S 2C7 | |
| CANADA | |
| 613-831-8318 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| BK-2-4[2] [3] | A2 | A | 100 - 110 | 61 - 71 | N/A | 4 | 10H | 27 | U.V. Light I.V. Pole |
| BK-2-4B3[2] | A2 | A | 100 - 110 | 61 - 71 | N/A | 4 | 10H | 27 | U.V. Light I.V. Pole |
| BK-2-4B3-BT[2] | A2 | B | 100 - 110 | 61 - 71 | N/A | 4 | 10H | NA | U.V. Light I.V. Pole |
| BK-2-4BT[2] [3] | A2 | B | 100 - 110 | 61 - 71 | N/A | 4 | 10H | NA | U.V. Light I.V. Pole |
| BK-2-6[1] [3] | A2 | A | 100 - 110 | 61 - 71 | N/A | 6 | 10H | 27 | U.V. Light I.V. Pole |
| BK-2-6B3[1] | A2 | A | 100 - 110 | 61 - 71 | N/A | 6 | 10H | 27 | U.V. Light I.V. Pole |
| BK-2-6B3-BT[1] | A2 | B | 100 - 110 | 61 - 71 | N/A | 6 | 10H | NA | U.V. Light I.V. Pole |
| BK-2-6BT[1] [3] | A2 | B | 100 - 110 | 61 - 71 | N/A | 6 | 10H | NA | U.V. Light I.V. Pole |
[1] Beginning with serial number 802-0954 and all subsequent units. Inflow nominal
set-point of 105 fpm was established with a direct airflow reading instrument. A
corresponding nominal set-point of 118 fpm was confirmed using manufacturer's
recommended alternate method with thermal anemometer above exhaust filter without
adjusting cabinet airflow balance. Downflow nominal set-point of 66 fpm was established
with U.V. Light and I.V. Pole installed. Certified for use with power supply of 220 V /
50 Hz.
[2] Beginning with serial number 801-1693 and all subsequent units. Inflow nominal
set-point of 105 fpm was established with a direct airflow reading instrument. A
corresponding nominal set-point of 122 fpm was confirmed using the manufacturer's
recommended alternate method with thermal anemometer above exhaust filter without
adjusting cabinet airflow balance. Downflow nominal set-point of 66 fpm was established
with U.V. Light and I.V. Pole installed. Certified for use with power supply of 220 V /
50 Hz.
[3] This model has an A2 type design clasification.
|
|||||||||
| NUAIRE, INC. | |
| 2100 FERNBROOK LANE | |
| PLYMOUTH, MN 55447 | |
| 763-553-1270 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| NU-425-400[1] [2] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 32 | I.V. Pole U.V. Light |
| NU-425-400[1] [2] [3] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 32 | I.V. Pole U.V. Light |
| NU-425-500[1] [3] [4] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 8S | 32 | U.V. Light I.V. Pole |
| NU-425-500[1] [3] [4] | A2 | A | 100 - 110 | 55 - 65 | N/A | 5 | 10S | 32 | U.V. Light I.V. Pole |
| NU-425-600[1] [3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 32 | I.V. Pole U.V. Light |
| NU-425-600[1] [3] [5] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 32 | I.V. Pole U.V. Light |
| NU-427-400[1] [6] | B1 | A | 100 - 110 | 65 - 75 | 282 @ 0.7 | 4 | 8S | 32 | Bag-In/Bag-Out I.V. Pole U.V. Light |
| NU-427-600[1] [7] | B1 | A | 100 - 110 | 65 - 75 | 474 @ 0.9 | 6 | 8S | 32 | I.V. Pole U.V. Light Bag-In/Bag-Out |
| NU-430-400[1] [8] [9] | B2 | A | 100 - 110 | 55 - 65 | 829 @ 1.7 | 4 | 8S | 32 | Bag-In/Bag-Out I.V. Pole U.V. Light Armrest |
| NU-430-600[1] [8] [10] | B2 | A | 100 - 110 | 55 - 65 | 1221 @ 2.0 | 6 | 8S | 32 | Bag-In/Bag-Out I.V. Pole U.V. Light |
| NU-480-400[1] [11] [12] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 10S | 33 | I.V. Pole U.V. Light |
| NU-480-400[1] [11] [12] | A2 | A | 100 - 110 | 55 - 65 | N/A | 4 | 8S | 33 | I.V. Pole U.V. Light |
| NU-480-600 | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 10S | 33 | I.V. Pole U.V. Light |
| NU-480-600[1] [11] [13] | A2 | A | 100 - 110 | 55 - 65 | N/A | 6 | 8S | 33 | I.V. Pole U.V. Light |
[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
density) was confirmed using manufacturer's recommended alternate method with thermal
anemometer in a constricted (3 inch high) access opening for appropriate correction
factor, if applicable, without adjusting cabinet airflow balance.
[2] Beginning with series 60 and higher. Downflow nominal set-point of 60 fpm was
established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
removed. This cabinet qualifies only with the armrest installed. This cabinet
qualifies with optional DC motor installed. This cabinet model was Certified to
NSF/ANSI 49–2004.
Listed model designation NU 437 with electronic control panel and airflow monitor.
Listed model designation NU 440 with electronic airflow control system.
Listed model may be prefaced with Q, N, L or S (i.e. NU-Q425-400).
[3] Listed model may be suffixed with E. Certified for use with power supplies of 230V/50Hz
and 230V/60Hz.
[4] Beginning with Series 60 and higher. Downflow nominal set-point of 60 fpm was
established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
removed. This cabinet qualifies only with the armrest installed. This cabinet
qualifies with optional DC motor installed. This cabinet model was Certified to
NSF/ANSI 49-2004.
Listed model designation NU 437 with electronic control panel and airflow monitor.
Listed model designation NU 440 with electronic airflow control system.
Listed model may be prefaced with Q, N, L, or S (i.e. NU-Q425-500).
[5] Beginning with series 60 and higher. Downflow nominal set-point of 60 fpm was
established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
removed. This cabinet qualifies only with the armrest installed. This cabinet
qualifies with optional DC motor installed. This cabinet model was Certified to
NSF/ANSI 49–2004.
Listed model designation NU 437 with electronic control panel and airflow monitor.
Listed model designation NU 440 with electronic airflow control system.
Listed model may be prefaced with Q, N, L or S (i.e. NU-Q425-600).
[6] Beginning with Series 40 and higher. Downflow nominal set-point of 70 fpm was
established 4 inches above the plane of the window with the I.V. Pole removed and U.V.
Light installed. This cabinet model was Certified to NSF/ANSI 49-2002. Listed model
may be prefaced with Q, N, L or S (i.e. NU-Q427-400).
[7] Beginning with series 40 and higher. Downflow nominal set-point of 70 fpm was
established 4 inches above the plane of the window with the I.V. Pole removed and U.V.
Light installed.
Listed model may be prefaced with Q, N, L or S (i.e. NU-Q427-600). This cabinet model
was Certified to NSF/ANSI 49-2004.
[8] Listed model designation NU 435 without U.V. Light option.
Listed model may be prefaced with Q, N, L or S (i.e. NU-Q435-400).
[9] Beginning with series 40 and higher. Downflow nominal set point of 60 fpm was
established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
removed. This cabinet model was Certified to NSF/ANSI 49-2004.
[10] Beginning with series 40 and higher. Downflow nominal set-point of 60 fpm was
established 4 inches above the plane of the window with the I.V. Pole removed and the
U.V. Light installed. Listed model may be prefaced with Q, N, L or S (i.e.
NU-Q430-600).
This cabinet model was Certified to NSF/ANSI 49-2002.
[11] Beginning with series 1 and higher. Downflow nominal set-point of 60 fpm was
established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
removed. This cabinet model was Certified to NSF/ANSI 49-2009.
[12] Certified for use with power supplies of 115V/60Hz, 230V/50Hz, and 230V/60Hz.
[13] Certified for use with power supplies of 115V/60Hz, 100V/50Hz, 11V/60Hz, and 230V/50Hz,
and 230V/60Hz.
|
|||||||||
| THERMO ELECTRON LED GMBH | |
| ROBERT-BOSCH-STRASSE 1 | |
| D-63505 LANGENSELBOLD | |
| GERMANY | |
| 49 61 813 5277 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| HS12[1] | A2 | A | 100 - 110 | 56 - 69 65 - 75 73 - 83 91 - 101 |
N/A | 4 | 8S | 32 | Armrest Full Side Windows |
| KS12[2] | A2 | A | 100 - 110 | 70 - 80 | N/A | 4 | 10 10H S |
34 | Full Side Windows U.V. Light I.V. Pole Armrest |
| KS15[5] | A2 | A | 100 - 110 | 65 - 75 | N/A | 5 | 10 10H S |
35 | Full Side Windows I.V. Pole U.V. Light Armrest |
| KS18[3] | A2 | A | 100 - 110 | 65 - 75 | N/A | 6 | 10 10H S |
34 | Full Side Windows I.V. Pole U.V. Light |
| KS9[4] | A2 | A | 100 - 110 | 65 - 75 | N/A | 3 | 10 10H S |
35 | Full Side Windows I.V. Pole U.V. Light Armrest |
[1] Beginning with serial number 99106700. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding nominal set-point
of 115 fmp was confirmed using the manufacturer's recommended alternate, calculated
inflow velocity method with thermal anemometer in a constricted access opening without
adjusting cabinet airflow balance. This model qualifies as having non-uniformed (zoned)
downflow only. The downflow nominal set-points were established utilizing four lateral
(side-to-side) zone grids beginning with zone 1 at the rear of the work area and ending
with zone 4 at the front of the work area behind the window. This cabinet qualifies
only with the armrest installed. This cabinet model was Certified with a 4 section work
surface.
[2] Beginning with serial number 40292176. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding inflow nominal
set-point of 105 fpm (corrected to local air density) was confirmed using the
manufacturer's recommended alternate method with thermal anemometer in a constricted (3
inch high) access opening (consult manufacturer's operator's manual for appropriate
correction factor, if applicable) without adjusting cabinet airflow balance. This
cabinet model was Certifed with a 4 section work surface. This cabinet model was
Certified to NSF/ANSI 49-2002.
[3] Beginning with serial number 40292176. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. A corresponding inflow nominal
set-point of 105 fpm (corrected to local air density) was confirmed using the
manufacturer's recommended alternate method with thermal anemometer in a constricted (3
inch high) access opening (consult manufacturer's operator's manual for appropriate
correction factor, if applicable) without adjusting cabinet airflow balance. This
cabinet model was Certified with a 6 section work surface. This cabinet model was
Certified to NSF/ANSI 49-2002.
[4] Beginning with serial number 40329642. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
for appropriate correction factor) without adjusting cabinet airflow balance. This
cabinet model was Certified with a 3 section work surface. This cabinet model was
Certified to NSF/ANSI 49-2002.
[5] Beginning with serial number 40349384. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
for appropriate correction factor) without adjusting cabinet airflow balance. This
cabinet model was Certified with a 5 section work surface. This cabinet model was
Certified to NSF/ANSI 49-2002.
|
|||||||||
| THERMO FISHER SCIENTIFIC | |
| 401 MILLCREEK ROAD | |
| MARIETTA, OH 45750 | |
| 740-373-4763 | |
| Visit this company's website |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 1200[1] | A1 | C | 75 - 85 | 65 - 75 | N/A | 4 | 10S | NA | U.V. Light I.V. Pole |
| 1201[1] | A1 | C | 75 - 85 | 65 - 75 | N/A | 4 | 10S | NA | U.V. Light I.V. Pole |
| 1205[2] | A1 | C | 80 - 90 | 65 - 75 | N/A | 6 | 10S | NA | U.V. Light I.V. Pole Casters |
| 1214[2] | A1 | C | 80 - 90 | 65 - 75 | N/A | 6 | 10S | NA | U.V. Light I.V. Pole Casters |
| 1284[3] | A2 | A | 105 - 115 | 65 - 75 | N/A | 4 | 10S | 33 | U.V. Light I.V. Pole Armrest |
| 1285[3] | A2 | A | 105 - 115 | 65 - 75 | N/A | 4 | 10S | 33 | U.V. Light I.V. Pole Armrest |
| 1286[4] | A2 | A | 105 - 115 | 70 - 80 | N/A | 6 | 10S | 33 | U.V. Light I.V. Pole Armrest |
| 1287[4] | A2 | A | 105 - 115 | 70 - 80 | N/A | 6 | 10S | 33 | U.V. Light I.V. Pole Armrest |
| 1345[6] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1346[6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1347[6] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1348[6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1354[5] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1355[6] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1356[6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1357[6] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1358[6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1359[5] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1375[6] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1376[6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1377[6] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1378[6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1384[5] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1385[6] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1386[6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 4 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1387[6] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1388[6] [7] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1389[5] | A2 | A | 100 - 110 | 58 - 68 | N/A | 6 | 10S | 36 | Armrest I.V. Pole U.V. Light |
| 1440[8] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 10S H |
36 | I.V. Pole U.V. Light 4 Section Work Surface Armrest |
| 1448[8] | A2 | A | 100 - 110 | 50 - 60 | N/A | 4 | 8S H |
36 | I.V. Pole U.V. Light 4 Section Work Surface Armrest |
| 1460[9] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 10S H |
36 | I.V. Pole U.V. Light 6 Section Work Surface Armrest |
| 1468[9] | A2 | A | 100 - 110 | 50 - 60 | N/A | 6 | 8S H |
36 | I.V. Pole U.V. Light 6 Section Work Surface Armrest |
[1] Beginning with serial number XXXXX-1. Inflow nominal set-point of 80 fpm was
established with a direct airflow reading instrument. A corresponding nominal set-point
of 80 fpm (corrected to local air density) was confirmed using manufacturer's
recommended alternate method with thermal anemometer in a constricted (3 inch high)
access opening (consult manufacturer's operator's manual for correction factor, if
applicable) without adjusting cabinet airflow balance. This cabinet model was Certified
to NSF/ANSI 49-2002.
[2] Beginning with serial number XXXXX-2. Inflow nominal set-point of 85 fpm established
with a direct airflow reading instrument. A corresponding nominal set-point of 85 fpm
was confirmed using manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
for correction factor, if applicable) with adjusting cabinet airflow balance. This
cabinet model was Certified to NSF/ANSI 49-2002.
[3] Beginning with serial number XXXXX-1. Inflow nominal set-point of 110 fpm was
established with a direct airflow reading instrument. The nominal set-point was
confirmed using the manufacturer's recommended alternate calculated method with thermal
anemometer in a constricted (3 inch high) access opening, (consult manufacturer's
operator's manual for appropriate correction factor) without adjusting cabinet airflow
balance. Downflow nominal set-point of 70 fpm was established with U.V. Light and I.V.
Pole removed per NSF/ANSI 49-2002.
[4] Beginning with serial number XXXXX-1 for models 1286 and 1287. Inflow nominal set-point
of 110 fpm was established with a direct airflow reading instrument. The nominal
set-point was confirmed using the manufacturer's recommended alternate calculated method
with thermal anemometer in a constricted (3 inch high) access opening, (consult
manufactuer's operator's manual for appropriate correction factor) without adjusting
cabinet airflow balance. Downflow nominal set-point of 75 fpm was established with U.V.
Light and I.V. Pole removed per NSF/ANSI 49-2002.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
instrument. This nominal set-point was confirmed using the manufacturer's recommended
alternate method with thermal anemometer in a constricted (3 inch high) access opening
(consult manufacturer for appropriate correction factor, if applicable), without
adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established
with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
49-2004. Certified for use with power supply of 220V/50Hz.
[6] Beginning with serial number XXXXX-1. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 63 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004. Certified for use with power supply of
120 V / 50 Hz and 120 V / 60 HZ.
[7] Certified for use with power supply of 220 V / 50 Hz and 220 V / 60 Hz.
[8] Beginning with serial number 102386. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
[9] Beginning with serial number 102428. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer for appropriate
correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004.
|
|||||||||
| THERMO FISHER SCIENTIFIC | |
| 401 MILLCREEK ROAD | |
| MARIETTA, OH 45750 | |
| 740-373-4763 |
| Model Number |
Cabinet Type/Style |
Inflow Velocity (fpm) |
Downflow Velocity (fpm) |
CBV (cfm) at Static Pressure (in w.g.) |
Cabinet Width ft. |
Window Ht/Type in. |
Bench Ht Max in. |
Acceptable Options |
|
| 1310[1] [2] | B2 | A | 100 - 110 | 50 - 60 | 810 @ 1.9 | 4 | 8S | 36 | Bag-In/Bag-Out I.V. Pole U.V. Light |
| 1360[3] [4] | B2 | A | 100 - 110 | 50 - 60 | 1218 @ 2.2 | 6 | 8S | 36 | Bag-In/Bag-Out I.V. Pole U.V. Light |
[1] Beginning with serial number 070570502. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (3 inch high) access opening (consult manufacturer's operator manual
for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
nominal set-point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
cabinet model was Certified to NSF/ANSI 49-2004. Model 1311 is equivalent to Model
1310, but comes equipped with U.V. lighting (Listed as an acceptable option).
[2] Certified for use with alternate power supplies. Model 1315 is equivalent to model
1310, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with
a Chinese-compatible plug. Model 1316 is equivalent, but is rated for use with power
supplies of 230V and 50/60 Hz and is equipped with U.V. lighting and a
Chinese-compatible plug. Model 1317 is equivalent, but is rated for use with power
supplies of 230V and 50/60 Hz and is equipped with a North American 230 Volt-compatible
plug. Model 1318 is equivalent, but is rated for use with power supplies of 230V and
50/60 Hz and is equipped with U.V. lighting and a North American 230 Volt-compatible
plug.
[3] Beginning with serial number 070900000. Inflow nominal set-point of 105 fpm was
established with a direct airflow reading instrument. This nominal set-point was
confirmed using the manufacturer's recommended alternate method with thermal anemometer
in a constricted (4.25 inch height) access opening (consult manufacturer’s operator
manual for appropriate correction factor) without adjusting cabinet airflow balance.
Downflow nominal set-point of 55 fpm was established with I.V. Pole and U.V. Light
removed. This cabinet model was Certified to NSF/ANSI 49-2007. Model 1361 is
equivalent to Model 1360, but is equipped with U.V. lighting (listed as an acceptable
option).
[4] Certified for use with alternate power supplies. Model 1362 is equivalent to model
1360, but is rated for use with power supplies of 230V and 50/60 Hz and is equipped with
a Chinese-compatible plug. Model 1363 is equivalent, but is rated for use with power
supplies of 230V and 50/60 Hz and is equipped with U.V. lighting and a
Chinese-compatible plug. Model 1364 is equivalent, but is rated for use with power
supplies of 230V and 50/60 Hz and is equipped with a North American 230 Volt-compatible
plug. Model 1365 is equivalent, but is rated for use with power supplies of 230 V and
50/60 Hz and is equipped with U.V. lighting and a North American 230 Volt-compatible
plug.
|
|||||||||