NSF Product and Service Listings

These NSF Official Listings are current as of Wednesday, May 8, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/Biosafety/Listings.asp?


NSF/ANSI 49
Class II (Laminar Flow) Biosafety Cabinetry

Cabinet Style
A = Bench Unit With Base or Adjustable Legs Provided
B = Bench Unit Without Base or Adjustable Legs Provided
C = Console
Window Type
H = Hinged
S = Sliding
F = Fixed
Bench Height
NA = Not Applicable
NP = Not Provided

CBV = Concurrent Balance Value

Due to a change in nomenclature in NSF/ANSI 49 - 2002 “Class II (Laminar Flow) Biosafety Cabinetry,” Class II, Type A cabinets are now referred to as Class II, Type A1 and Class II, Types B3 and A/B3 cabinets as Class II, Type A2. Class II, Types B1 and B2 cabinets remain unchanged.

Biosafety cabinet models Listed under NSF/ANSI 49 are approved for use with a power supply of 115V/60Hz, unless otherwise noted. If biosafety cabinets have been approved for use with additional power supplies, the power supply will be indicated in the Official Listing.



Across International LLC 
111 Dorsa Avenue
Livingston, NJ 07039 
United States 
888-988-0899 
Visit this company's website
Facility : Shandong, China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
BC-2F[1] A2 A 100 - 110 60 - 70 N/A 2 10S 28 U.V. Light
Canopy Connection
BC-3F[2] A2 A 100 - 110 60 - 70 N/A 3 10S 27 Canopy Connection
I.V. Pole
U.V. Light
BC-4F[3] A2 A 100 - 110 60 - 70 N/A 4 10S 27 I.V. Pole
U.V. Light
Canopy Connection
BC-4FB2[2] B2 A 100 - 110 60 - 70 949 @ 2.1 4 8S 27 I.V. Pole
U.V. Light
BC-6F[4] A2 A 100 - 110 60 - 70 N/A 6 10S 27 I.V. Pole
Canopy Connection
U.V. Light

[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer's operator's manual for appropriate correction factor) without
    adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
    with U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2020. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
    Canopy connection model number is 2T-C.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument.  This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer's operator's manual for appropriate correction factor) without
    adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
    with I.V. Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI
    49-2016. Biobase canopy model CY-3FA2-I was evaluated as a part of the NSF Certification
    testing procedures. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and
    230V/60Hz.
[3] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local
    air density) was confirmed using manufacturer's recommended alternate method with
    thermal anemometer in a constricted (3 inch high) access opening and applying
    appropriate correction factor without adjusting cabinet airflow balance. The downflow
    nominal set-point of 65 fpm was established 4 inches above the bottom of the sash with
    the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
[4] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal
    set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
    Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI 49-2014. 
    Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.								



 
Allentown, LLC 
Route 526
Allentown, NJ 08501-0698 
United States 
609-259-7951
Visit this company's website
Facility : # 1 USA

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
39241[1] [2] A2 A 100 - 110 50 - 60 N/A 4 10S 36 Canopy Connection
I.V. Pole
U.V. Light
39242xxx1 Safety Cab.[1] [3] A2 A 100 - 110 55 - 65 N/A 4 12S 36 Canopy Connection
I.V. Pole
U.V. Light
39248[1] [2] A2 A 100 - 110 50 - 60 N/A 4 8S 36 Canopy Connection
I.V. Pole
U.V. Light
39251[1] [2] A2 A 100 - 110 50 - 60 N/A 5 10S 36 Canopy Connection
I.V. Pole
U.V. Light
39252xxx1 Safety Cab.[1] [4] A2 A 100 - 110 55 - 65 N/A 5 12S 36 Canopy Connection
I.V. Pole
U.V. Light
39258[1] [2] A2 A 100 - 110 50 - 60 N/A 5 8S 36 Canopy Connection
I.V. Pole
U.V. Light
39261[1] [2] A2 A 100 - 110 50 - 60 N/A 6 10S 36 Canopy Connection
I.V. Pole
U.V. Light
39262xxx1 Safety Cab.[1] [3] A2 A 100 - 110 55 - 65 N/A 6 12S 36 Canopy Connection
I.V. Pole
U.V. Light
39268[1] [2] A2 A 100 - 110 50 - 60 N/A 6 8S 36 Canopy Connection
I.V. Pole
U.V. Light

[1] Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    measurement. This nominal set point was confirmed using the manufacturer's
    recommended alternate method with thermal anemometer in a constricted access opening,
    using the manufacturer-supplied probe holder and sash stop (consult manufacturer for
    appropriate correction factor, if applicable), without adjusting cabinet
    airflow balance. Downflow nominal set point of 55 fpm was established with I.V. pole
    and U.V. light removed. This cabinet model was Certified to NSF/ANSI 49-2012.
    This cabinet model is Certified for use with optional sidewall Vacu-PassTM Cord
    and Cable Portal.
    
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted access opening, using the
    manufacturer-supplied probe holder and sash stop (consult manufacturer for
    appropriate correction factor, if applicable), without adjusting cabinet airflow
    balance. Downflow nominal set point of 55 fpm was established with I.V. Pole and U.V.
    Light removed. This cabinet model was Certified to NSF/ANSI 49-2018. This cabinet
    model is Certified for use with optional sidewall Vacu-PassTM Cord & Cable Portal.
[4] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted access opening, using the
    manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
    correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
    nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed.
    This cabinet model was Certified to NSF/ANSI 49-2018. This cabinet model is Certified
    for use with optional sidewall Vacu-PassTM Cord & Cable Portal.



 
Baker Company, Inc. (The) 
175 Gatehouse Road
Sanford, ME 04073 
United States 
800-992-2537 
207-324-8773
Visit this company's website
Facility : Sanford, ME

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
BCG401[1] B2 C 100 - 110 35 - 45 664 @ 1.6 4 8S 35 I.V. Pole
U.V. Light
Casters
BCG601[1] B2 C 100 - 110 35 - 45 993 @ 1.6 6 8S 35 I.V. Pole
U.V. Light
SG404[2] [3] [4] [5] A2 A 100 - 110 47 - 57
42 - 52
N/A 4 8S 37 I.V. Pole
U.V. Light
Casters
Canopy Connection
SG404[2] [3] [4] [5] A2 A 100 - 110 47 - 57
42 - 52
N/A 4 10S 37 I.V. Pole
U.V. Light
Casters
Canopy Connection
SG404[2] [3] [4] [5] A2 A 100 - 110 47 - 57
42 - 52
N/A 4 12S 37 I.V. Pole
U.V. Light
Casters
Canopy Connection
SG504[2] [3] [5] [6] A2 A 100 - 110 45 - 55
42 - 52
N/A 5 8S 37 I.V. Pole
U.V. Light
Casters
Canopy Connection
SG504[2] [3] [5] [6] A2 A 100 - 110 45 - 55
42 - 52
N/A 5 10S 37 I.V. Pole
U.V. Light
Casters
Canopy Connection
SG504[2] [3] [5] [7] A2 A 100 - 110 45 - 55
40 - 50
N/A 5 12S 37 I.V. Pole
U.V. Light
Casters
Canopy Connection
SG604[2] [3] [5] [8] A2 A 100 - 110 48 - 58
42 - 52
N/A 6 8S 37 Casters
Canopy Connection
I.V. Pole
U.V. Light
SG604[2] [3] [5] [8] A2 A 100 - 110 48 - 58
42 - 52
N/A 6 10S 37 Casters
Canopy Connection
I.V. Pole
U.V. Light
SG604[2] [3] [5] [9] A2 A 100 - 110 42 - 52
36 - 46
N/A 6 12S 37 Canopy Connection
Casters
I.V. Pole
U.V. Light

[1] Beginning with serial number 103539 for the 4-foot model and serial number 103706 for
    the 6-foot model.  Inflow nominal setpoint of 105 fpm was established with a direct
    airflow reading instrument.  This nominal set point was confirmed using the
    manufacturer's recommended alternate calculated method with thermal anemometer in a
    constricted (3 inch high) access opening (consult manufacturer's operator's manual for
    appropriate correction factor), without adjusting cabinet airflow balance.  Downflow
    nominal set point was established with I.V. Pole and U.V. Light removed.  This cabinet
    model was Certified to NSF/ANSI 49-2010a.  This cabinet qualifies only with the armrest
    installed.  This cabinet is approved with additional petcocks on the sidewalls and a low
    static pressure exhaust plenum.  Cabinet models BCG401 INT and BCG601 INT are Certified
    for alternate motor/blower combinations and input power supply.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument.  This nominal set point was confirmed using the manufacturer's recommended
    alternate calculated method with thermal anemometer in a constricted (3 inch high)
    access opening (consult manufacturer's operator's manual for appropriate correction
    factor, if applicable).
[3] Baker model designations SG404-AUS and SG604-AUS are Certified to NSF/ANSI 49-2012 for
    operation at 220V/50Hz with an 8-inch window opening.  Baker model designations
    SG404-INT, SG504-INT, and SG604-INT are Certified to NSF/ANSI 49-2012 for operation at
    either 220V/50Hz or 220V/60Hz.
[4] Beginning with serial number 110235.  The acceptable non-uniform downflow ranges listed
    above begin with zone 1 (47-57 fpm) at the rear of the work area (compromised of lateral
    rear and center rows) and end with zone 2 (42-52 fpm) (comprised of front lateral row)
    behind the front  window enclosing the work area.  Downflow nominal set points were
    established with the I.V. Pole and U.V. Light removed.  This cabinet model was Certified
    to NSF/ANSI 49-2012.  This cabinet qualifies only with the armrest installed.  FlexAir
    Canopy connection 333A745 is approved for use with this model.
[5] The maximum height for the bench stand with casters is 30 inches.  The maximum height
    for the bench stand with feet is 37 inches.
[6] Beginning with serial number 110795.  The acceptable non-uniform downflow ranges listed
    above begin with zone 1 (45-55 fpm) at the rear of the work area (compromised of lateral
    rear and center rows) and end with zone 2 (42-52 fpm) (comprised of front lateral row)
    behind the front window enclosing the work area.  Downflow nominal set points were
    established with the I.V. Pole and U.V. Light removed.  This cabinet model was Certified
    to NSF/ANSI 49-2012.  This cabinet qualifies only with the armrest installed.  FlexAir
    Canopy connection 336A745 is approved for use with this model.
[7] Beginning with serial number 110795.  The acceptable non-uniform downflow ranges listed
    above begin with zone 1 (45-55 fpm) at the rear of the work area (compromised of lateral
    rear and center rows) and end with zone 2 (40-50 fpm) (comprised of front lateral row)
    behind the front window enclosing the work area.  Downflow nominal set points were
    established with the I.V. Pole and U.V. Light removed.  This cabinet model was Certified
    to NSF/ANSI 49-2012.  This cabinet qualifies only with the armrest installed.  FlexAir
    Canopy connection 336A745 is approved for use with this model.
[8] Beginning with serial number 110555.  The acceptable non-uniform downflow ranges listed
    above begin with zone 1 (48-58 fpm) at the rear of the work area (compromised of lateral
    rear and center rows) and end with zone 2 (42-52 fpm) (comprised of front lateral row)
    behind the front window enclosing the work area.  Downflow nominal set points were
    established with the I.V. Pole and U.V. Light removed.  This cabinet model was Certified
    to NSF/ANSI 49-2012.  This cabinet qualifies only with the armrest installed.  FlexAir
    Canopy connection 336A745 is approved for use with this model.
[9] Beginning with serial number 110555.  The acceptable non-uniform downflow ranges listed
    above begin with zone 1 (42-52 fpm) at the rear of the work area (compromised of lateral
    rear and center rows) and end with zone 2 (36-46 fpm) (comprised of front lateral row)
    behind the front window enclosing the work area.  Downflow nominal set points were
    established with the I.V. Pole and U.V. Light removed.  This cabinet model was Certified
    to NSF/ANSI 49-2012.  This cabinet qualifies only with the armrest installed.  FlexAir
    Canopy connection 336A745 is approved for use with this model.



 
CHC Biotech Co., Ltd. 
2nd Floor of W1 Building
150 Gwahakseongjang-ro 
Yuseong-gu, Daejeon 305-500 
Korea, Republic of 
82 42 936 5530
Visit this company's website
Facility : CHC Biotech Co., Ltd. – Republic of Korea

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
NB-704[1] [2] A2 A 100 - 110 55 - 65 4 8S 26 I.V. Pole
U.V. Light
NB-706[1] [2] A2 A 100 - 110 55 - 65 6 8S 26 I.V. Pole
U.V. Light

[1] Certified for use with power supplies of 115V/60 Hz, 230V/50 Hz and 230V/60 Hz.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's alternate
    recommended method with thermal anemometer in a constricted (3 inch high) access opening
    consult manufacturer's operator's manual for appropriate correction factor), without
    adjusting cabinet airflow balance. Downflow nominal set point was established with I.V.
    Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2020. This
    cabinet qualifies only with the armrest installed.



 
Chung Fu Technical Development Co., Ltd. 
7F, No. 687, Mintsu East Road
Taipei 105 
Taiwan 
886 2 2600 1761
Visit this company's website
Facility : New Taipei City, Taiwan

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
AHA-133-AA-B[1] [2] A2 A 100 - 110 54 - 64 N/A 4 10S 28 I.V. Pole
U.V. Light
AHA-133-AB-B[1] [2] [3] A2 A 100 - 110 54 - 64 N/A 4 10S 28 I.V. Pole
U.V. Light
AHA-133-AC-B[1] [2] [4] A2 A 100 - 110 54 - 64 N/A 4 10S 28 I.V. Pole
U.V. Light
AHA-133-CA-B[1] [5] A2 A 100 - 110 54 - 64 N/A 4 10S 28 I.V. Pole
U.V. Light
AHA-133-CB-B[1] [3] [5] A2 A 100 - 110 54 - 64 N/A 4 10S 28 I.V. Pole
U.V. Light
AHA-133-CC-B[1] [4] [5] A2 A 100 - 110 54 - 64 N/A 4 10S 28 I.V. Pole
U.V. Light
AHA-193-AA-A[2] [6] A2 A 100 - 110 54 - 64 N/A 6 8S 29 I.V. Pole
U.V. Light
AHA-193-AB-A[2] [3] [6] A2 A 100 - 110 54 - 64 N/A 6 8S 29 I.V. Pole
U.V. Light
AHA-193-AC-A[2] [4] [6] A2 A 100 - 110 54 - 64 N/A 6 8S 29 I.V. Pole
U.V. Light
AHA-193-CA-A[5] [6] A2 A 100 - 110 54 - 64 N/A 6 8S 29 I.V. Pole
U.V. Light
AHA-193-CB-A[3] [5] [6] A2 A 100 - 110 54 - 64 N/A 6 8S 29 I.V. Pole
U.V. Light
AHA-193-CC-A[4] [5] [6] A2 A 100 - 110 54 - 64 N/A 6 8S 29 I.V. Pole
U.V. Light

[1] Beginning with serial number AHA1608060. Inflow nominal set point of 105 fpm was
    established with a direct airflow reading instrument.  A corresponding inflow nominal
    set point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
    recommended alternate method with thermal anemometer in a constricted (3 inch high)
    access opening and applying appropriate correction factor without adjusting cabinet
    airflow balance.  The downflow nominal set-point of 59 fpm was established 4 inches
    above the bottom of the sash with the I.V. Pole and U.V. Light removed.  This cabinet
    model was Certified to NSF/ANSI 49-2014. Chung Fu Technical Development Co., Ltd. Models
    AHA-133-AA-B, AHA-133-AB-B, AHA-133-AC-B, AHA-133-CA-B, AHA-133-CB-B and AHA-133-CC-B
    are marketed by Air Science, LLC, USA as Air Science Models AS-AHA-133-AA-B,
    AS-AHA-133-AB-B, AS-AHA-133-AC-B, AS-AHA-133-CA-B, AS-AHA-133-CB-B and AS-AHA-133-CC-B,
    respectively.
[2] Control panel is touch screen on this model.
[3] Certified for use with power supplies of 230V/50Hz and 230V/60Hz.
[4] Certified for use with power supplies of 100V/50Hz and 100V/60Hz.
[5] Control panel is membrane switch on this model.
[6] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. The downflow nominal set-point of 59 fpm was established 4 inches above the
    bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was
    Certified to NSF/ANSI 49-2020. Chung Fu Technical Development Co., Ltd. Models
    AHA-193-AA-A, AHA-193-AB-A,AHA-193-AC-A, AHA-193-CA-A, AHA-193-CB-A and AHA-193-CC-A are
    marketed by Air Science, LLC, USA as Air Science Models AS-AHA-193-AA-A,
    AS-AHA-193-AB-A, AS-AHA-193-AC-A, AS-AHA-193-CA-A, AS-AHA-193-CB-A and AS-AHA-193-CC-A,
    respectively.



 
Design Filtration Microzone Inc. 
86 Harry Douglas Drive
Ottawa, ON K2S 2C7 
Canada 
613-831-8318
Visit this company's website
Facility : Shandong Province, China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
BK-3-4[1] A2 A 100 - 110 60 - 70 N/A 4 10S 27 Canopy Connection
I.V. Pole
U.V. Light
BK-3-6[2] A2 A 100 - 110 60 - 70 N/A 6 10S 27 I.V. Pole
U.V. Light
Canopy Connection
BK3-4[3] [4] A2 A 100 - 110 60 - 70 N/A 4 8S 27 I.V. Pole
U.V. Light

[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. A corresponding inflow nominal set point of 105 fpm (corrected to local
    air density) was confirmed using manufacturer's recommended alternate method with
    thermal anemometer in a constricted (3 inch high) access opening and applying
    appropriate correction factor without adjusting cabinet airflow balance. The downflow 
    nominal set point of 65 fpm was established 4 inches above the bottom of the sash with
    the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2014. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
[2] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal
    set-point of 65 fpm was
    established 4 inches above the bottom of the sash with the I.V. Pole and U.V. Light
    removed. This cabinet model was Certified to NSF/ANSI 49-2014.  Certified for use with
    power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
[3] Approved for alternate power modes of 220V/50Hz and 220V/60Hz.
[4] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set-point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set-point of 65 fpm was established
    with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2012.



 
Esco Micro Pte Ltd 
21 Changi South Street 1
486777 
Singapore 
65 6542 0833
Visit this company's website
Facility : Kepulauan Riau, Indonesia

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
AC2-3E8-NS G4 8"[1] [2] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-3E9-NS G4 8"[1] [3] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-3J7 G4 8"[1] [4] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-3N7 G4 8" [1] [4] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-3S8-NS G4 8"[1] [2] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-3S9-NS G4 8"[1] [3] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-3Y7 G4 8"[1] [4] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4E8-NS G4 10"[2] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4E8-NS G4 8"[2] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4E9-NS G4 10"[3] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4E9-NS G4 8" [3] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4J7 G4 10"[4] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4J7 G4 8"[4] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4N7 G4 10"[4] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4N7 G4 8"[4] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4S8-NS G4 10"[2] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4S8-NS G4 8"[2] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4S9-NS G4 10"[3] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4S9-NS G4 8"[3] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4Y7 G4 10"[4] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-4Y7 G4 8"[4] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-5E8-NS G4 8"[2] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-5E9-NS G4 8"[3] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-5J7 G4 8" [4] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-5N7 G4 8"[4] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-5S8-NS G4 8"[2] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-5S9-NS G4 8"[3] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-5Y7 G4 8"[4] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6E8-NS G4 10"[2] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6E8-NS G4 8"[2] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6E9-NS G4 10"[3] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6E9-NS G4 8"[3] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6J7 G4 10"[4] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6J7 G4 8"[4] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6N7 G4 10"[4] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6N7 G4 8"[4] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6S8-NS G4 10" [2] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6S8-NS G4 8"[2] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6S9-NS G4 10"[3] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6S9-NS G4 8"[3] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6Y7 G4 10"[4] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AC2-6Y7 G4 8"[4] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-3E8 G4 8"[1] [2] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-3E9 G4 8"[1] [3] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-3S8 G4 8"[1] [2] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-3S9 G4 8"[1] [3] A2 A 100 - 110 55 - 65 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-4E8 G4 10"[2] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-4E8 G4 8"[2] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-4E9 G4 10"[3] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-4E9 G4 8"[3] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-4S8 G4 10"[2] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-4S8 G4 8"[2] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-4S9 G4 10"[3] [5] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-4S9 G4 8"[3] [5] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-5E8 G4 8"[2] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-5E9 G4 8"[3] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-5S8 G4 8"[2] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-5S9 G4 8"[3] [6] A2 A 100 - 110 55 - 65 N/A 5 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-6E8 G4 10"[2] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-6E8 G4 8"[2] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-6E9 G4 10"[3] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-6E9 G4 8"[3] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-6S8 G4 10"[2] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-6S8 G4 8"[2] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-6S9 G4 10"[3] [7] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
AR2-6S9 G4 8"[3] [7] A2 A 100 - 110 55 - 65 N/A 6 8S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-4J7 G4 10"[4] [8] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-4J7 G4 12"[4] [8] A2 A 100 - 110 55 - 65 N/A 4 12S 36 I.V. Pole
U.V. Light
LA2-4J7 G4 8"[4] [8] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
LA2-4N7 G4 10"[4] [8] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-4N7 G4 12"[4] [8] A2 A 100 - 110 55 - 65 N/A 4 12S 36 I.V. Pole
U.V. Light
LA2-4N7 G4 8"[4] [8] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
LA2-4S8 G4 10"[2] [8] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-4S8 G4 12"[2] [8] A2 A 100 - 110 55 - 65 N/A 4 12S 36 I.V. Pole
U.V. Light
LA2-4S8 G4 8"[2] [8] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
LA2-4S9 G4 10"[3] [8] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-4S9 G4 12"[3] [8] A2 A 100 - 110 55 - 65 N/A 4 12S 36 I.V. Pole
U.V. Light
LA2-4S9 G4 8"[3] [8] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
LA2-4Y7 G4 10"[4] [8] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-4Y7 G4 12"[4] [8] A2 A 100 - 110 55 - 65 N/A 4 12S 36 I.V. Pole
U.V. Light
LA2-4Y7 G4 8"[4] [8] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
LA2-5J7 G4 10"[4] [9] A2 A 100 - 110 60 - 70 N/A 5 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-5N7 G4 10"[4] [9] A2 A 100 - 110 60 - 70 N/A 5 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-5S8 G4 10"[2] [9] A2 A 100 - 110 60 - 70 N/A 5 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-5S9 G4 10"[3] [9] A2 A 100 - 110 60 - 70 N/A 5 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-5Y7 G4 10"[4] [9] A2 A 100 - 110 60 - 70 N/A 5 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-6J7 G4 10"[4] [8] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-6J7 G4 12"[4] [10] A2 A 100 - 110 65 - 75 N/A 6 12S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-6N7 G4 10"[4] [8] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-6N7 G4 12"[4] [10] A2 A 100 - 110 65 - 75 N/A 6 12S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-6S8 G4 10"[2] [8] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-6S8 G4 12"[2] [10] A2 A 100 - 110 65 - 75 N/A 6 12S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-6S9 G4 10"[3] [8] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-6S9 G4 12"[3] [10] A2 A 100 - 110 65 - 75 N/A 6 12S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-6Y7 G4 10"[4] [8] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LA2-6Y7 G4 12"[4] [10] A2 A 100 - 110 65 - 75 N/A 6 12S 36 I.V. Pole
U.V. Light
Canopy Connection
LB2-4B7 G4[4] [11] B2 A 100 - 110 55 - 65 887 @ 1.9 4 8S 35 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-4B8 G4[2] [11] B2 A 100 - 110 55 - 65 887 @ 1.9 4 8S 35 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-4B9 G4[3] [11] B2 A 100 - 110 55 - 65 887 @ 1.9 4 8S 35 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-4Y7 G4[4] [11] B2 A 100 - 110 55 - 65 887 @ 1.9 4 8S 35 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-4Y8 G4[2] [11] B2 A 100 - 110 55 - 65 887 @ 1.9 4 8S 35 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-4Y9 G4[3] [11] B2 A 100 - 110 55 - 65 887 @ 1.9 4 8S 35 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-6B7 G4[4] [12] B2 A 100 - 110 55 - 65 1276 @ 2.7 6 8S 34 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-6B8 G4[2] [12] B2 A 100 - 110 55 - 65 1276 @ 2.7 6 8S 34 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-6B9 G4[3] [12] B2 A 100 - 110 55 - 65 1276 @ 2.7 6 8S 34 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-6Y7 G4[4] [12] B2 A 100 - 110 55 - 65 1276 @ 2.7 6 8S 34 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-6Y8 G4[2] [12] B2 A 100 - 110 55 - 65 1276 @ 2.7 6 8S 34 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LB2-6Y9 G4[3] [12] B2 A 100 - 110 55 - 65 1276 @ 2.7 6 8S 34 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
LR2-4S8 G4 10"[2] [8] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LR2-4S8 G4 12"[2] [8] A2 A 100 - 110 55 - 65 N/A 4 12S 36 I.V. Pole
U.V. Light
LR2-4S8 G4 8"[2] [8] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
LR2-4S9 G4 10"[3] [8] A2 A 100 - 110 55 - 65 N/A 4 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LR2-4S9 G4 12"[3] [8] A2 A 100 - 110 55 - 65 N/A 4 12S 36 I.V. Pole
U.V. Light
LR2-4S9 G4 8"[3] [8] A2 A 100 - 110 55 - 65 N/A 4 8S 36 I.V. Pole
U.V. Light
LR2-5S8 G4 10"[2] [9] A2 A 100 - 110 55 - 65 N/A 5 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LR2-5S9 G4 10"[3] [9] A2 A 100 - 110 55 - 65 N/A 5 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LR2-6S8 G4 10"[2] [8] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LR2-6S8 G4 12"[2] [10] A2 A 100 - 110 65 - 75 N/A 6 12S 36 I.V. Pole
U.V. Light
Canopy Connection
LR2-6S9 G4 10"[3] [8] A2 A 100 - 110 55 - 65 N/A 6 10S 36 I.V. Pole
U.V. Light
Canopy Connection
LR2-6S9 G4 12"[3] [10] A2 A 100 - 110 65 - 75 N/A 6 12S 36 I.V. Pole
U.V. Light
Canopy Connection
VA2-4S8 G4 12"[2] [8] A2 A 100 - 110 55 - 65 N/A 4 12S 36 I.V. Pole
U.V. Light
VA2-4S9 G4 12"[3] [8] A2 A 100 - 110 55 - 65 N/A 4 12S 36 I.V. Pole
U.V. Light
VA2-6S8 G4 12"[2] [10] A2 A 100 - 110 65 - 75 N/A 6 12S 36 I.V. Pole
U.V. Light
Canopy Connection
VA2-6S9 G4 12"[3] [10] A2 A 100 - 110 65 - 75 N/A 6 12S 36 I.V. Pole
U.V. Light
Canopy Connection

[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance.  Downflow nominal set point of 60 fpm was established
    4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed. This
    cabinet model was Certified to NSF/ANSI 49-2022.
[2] Certified for use with a power supply of 230V/50Hz and 230V/60Hz.											
[3] Certified for use with a power supply of 110V-120V/50Hz and 110V-120V/60Hz.
[4] Approved for alternate power modes of 100V/50Hz and 100V/60Hz.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument.  This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance.  Downflow nominal set point of 60 fpm was established
    with I.V. Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI
    49-2022.
[6] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
    4 inches above the bottom of the sash with the I.V. Pole and U.V. Light removed.  This
    cabinet model was Certified to NSF/ANSI 49-2022.
[7] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument.  This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance.  Downflow nominal set point of 60 fpm was established
    with I.V. Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI
    49-2022.
[8] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
    with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2014.
[9] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
    with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2014.
[10] Inflow nominal set point of 105 fpm was established with a direct airflow reading
     instrument.  This nominal set point was confirmed using the manufacturer's recommended
     alternate method with thermal anemometer in a constricted (3 inch high) access opening
     (consult manufacturer for appropriate correction factor, if applicable), without
     adjusting cabinet airflow balance. Downflow nominal set point of 70 fpm was established
     with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
     49-2014.
[11] Inflow nominal set point of 105 fpm was established with a direct airflow reading
     instrument. This nominal set point was confirmed using the manufacturer's recommended
     alternate method with thermal anemometer in a constricted (3 inch high) access opening
     (consult manufacturer for appropriate correction factor, if applicable), without
     adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
     with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
     49-2020.
[12] Inflow nominal set point of 105 fpm was established with a direct airflow reading
     instrument.  This nominal set point was confirmed using the manufacturer's recommended
     alternate method with thermal anemometer in a constricted (3 inch high) access opening
     (consult manufacturer for appropriate correction factor, if applicable), without
     adjusting cabinet airflow balance.  Downflow nominal set point of 60 fpm was established
     with I.V. Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI
     49-2022.



 
Germfree Laboratories, LLC 
4 Sunshine Boulevard
Ormond Beach, FL 32174 
United States 
386-265-4360
Visit this company's website
Facility : Ormond Beach, FL

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
BSCA-4 A2 A 100 - 110 54 - 64
54 - 64
40 - 50
N/A 4 10S 32 I.V. Pole
Canopy Connection

[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended 
    alternate method with thermal anemometer in a constricted (3 inch high) access opening 
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. The acceptable non-uniform downflow ranges listed
    above begin with zone 1 (54-64 fpm) closest to the back wall of the cabinet, zone 2
    (54-64 fpm) center of the cabinet, and end with zone 3 (40-50 fpm) closest to the front
    sliding window.  Downflow nominal set points were established with the I.V. Pole
    removed.  This cabinet model was Certified to NSF/ANSI 49-2020.  This cabinet qualifies
    only with the armrest installed. Certified for use with a power supply of 100V/50Hz/60Hz
    and 230V/50Hz/60Hz. Additional options are I.V. pole, canopy model BSCA-4C, casters and
    modified-passthrough.


 
Jinan Biobase Biotech Co., Ltd. 
North side of Jiwang Road, Mingshui
Economic Dev. Zone, Zhangqiu Jinan 
Shandong Province 250200 
China 
86 531 5867 3159
Visit this company's website
Facility : # 37 China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
BSC-2FA2-GL[1] A2 A 100 - 110 60 - 70 N/A 2 10S 28 U.V. Light
Canopy Connection
BSC-2FA2-NA[1] A2 A 100 - 110 60 - 70 N/A 2 10S 28 U.V. Light
Canopy Connection
BSC-3FA2-GL[2] A2 A 100 - 110 60 - 70 N/A 3 10S 27 Canopy Connection
I.V. Pole
U.V. Light
BSC-3FA2-NA[2] A2 A 100 - 110 60 - 70 N/A 3 10S 27 Canopy Connection
I.V. Pole
U.V. Light
BSC-4FA2[3] A2 A 100 - 110 60 - 70 N/A 4 8S 27 I.V. Pole
U.V. Light
BSC-4FA2-GL[4] A2 A 100 - 110 60 - 70 N/A 4 10S 27 I.V. Pole
U.V. Light
Canopy Connection
BSC-4FA2-NA[4] A2 A 100 - 110 60 - 70 N/A 4 10S 27 I.V. Pole
U.V. Light
Canopy Connection
BSC-4FB2-GL[5] B2 A 100 - 110 60 - 70 949 @ 2.1 4 8S 27 I.V. Pole
U.V. Light
BSC-4FB2-NA[5] B2 A 100 - 110 60 - 70 949 @ 2.1 4 8S 27 I.V. Pole
U.V. Light
BSC-6FA2-GL[6] A2 A 100 - 110 60 - 70 N/A 6 10S 27 I.V. Pole
Canopy Connection
U.V. Light
BSC-6FA2-NA[6] A2 A 100 - 110 60 - 70 N/A 6 10S 27 I.V. Pole
Canopy Connection
U.V. Light

[1]  Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument.  This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer's operator's manual for appropriate correction factor) without
    adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
    with I.V. Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI
    49-2020. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
    Canopy connection model number is 2FT-CC.
[2] Beginning with serial number NA3FAT220600001AY.  Inflow nominal set point of 105 fpm was
    established with a direct airflow reading instrument.  This nominal set point was
    confirmed using the manufacturer's recommended alternate method with thermal anemometer
    in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
    for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
    nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed.  This
    cabinet model was Certified to NSF/ANSI 49-2016. Biobase canopy model 3FT-CC was
    evaluated as a part of the NSF Certification testing procedures. Certified for use with
    power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. A corresponding inflow nominal set point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal set
    point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole
    and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI 49-2012.  Biobase
    canopy model 4FE-CC was evaluated as a part of the NSF Certification testing procedures.
    Approved for alternate power modes of 115V/60Hz, 220V/50Hz and 220V/60Hz.
[4] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local
    air density) was confirmed using manufacturer's recommended alternate method with
    thermal anemometer in a constricted (3 inch high) access opening and applying
    appropriate correction factor without adjusting cabinet airflow balance. The downflow
    nominal set-point of 65 fpm was established 4 inches above the bottom of the sash with
    the I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2014. Biobase canopy model 4FT-CC was evaluated as a part of the NSF Certification
    testing procedures. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and
    230V/60Hz.
[5] Beginning with serial number 4FB18050001.  Inflow nominal set point of 105 fpm was
    established with a direct airflow reading instrument.  This nominal set point was
    confirmed using the manufacturer's recommended alternate method with thermal anemometer
    in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
    for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
    nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed.  This
    cabinet model was Certified to NSF/ANSI 49-2016. Certified for use with power supplies
    of 115V/60Hz, 230V/50Hz and 230V/60Hz.
[6] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal
    set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
    Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI 49-2014. 
    Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.								
    



 
Kewaunee Scientific Corporation 
2700 West Front Street
Statesville, NC 28677 
United States 
704-873-7202
Visit this company's website
Facility : Karnataka, India

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
INT-B1400-2[1] [2] B2 A 100 - 110 55 - 65 937@2.4 4 8S 36 I.V. Pole
U.V. Light
INT-B2000-2[1] [2] B2 A 100 - 110 55 - 65 1416@2.0 6 8S 36 I.V. Pole
U.V. Light

[1] Also Certified for use with power supplies of 230V/50Hz and 230V/60Hz. Model numbers may
    be followed by -230 suffix.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument.  This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was
    established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to
    NSF/ANSI 49-2016.



 
Labconco Corporation 
8845 Prospect
Kansas City, MO 64132 
United States 
816-333-8811 X771
Visit this company's website
Facility : Kansas City, MO

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
30231xxx1 Logic+[1] [2] A2 A 100 - 110 50 - 60 N/A 3 10S 36 I.V. Pole
U.V. Light
Canopy Connection
30238xxx1 Logic+[1] [3] A2 A 100 - 110 50 - 60 N/A 3 8S 36 I.V. Pole
U.V. Light
Canopy Connection
30241xxx1 Logic+[1] [3] A2 A 100 - 110 50 - 60 N/A 4 10S 36 Canopy Connection
I.V. Pole
U.V. Light
30242xxx1 Logic+[3] [4] A2 A 100 - 110 50 - 60 N/A 4 12S 36 Canopy Connection
I.V. Pole
U.V. Light
30248xxx1 Logic+[1] [3] A2 A 100 - 110 50 - 60 N/A 4 8S 36 Canopy Connection
I.V. Pole
U.V. Light
30251xxx1 Logic+[1] [3] A2 A 100 - 110 50 - 60 N/A 5 10S 36 I.V. Pole
U.V. Light
Canopy Connection
30252xxx1 Logic+[3] [5] A2 A 100 - 110 55 - 65 N/A 5 12S 36 Canopy Connection
I.V. Pole
U.V. Light
30258xxx1 Logic+[1] [3] A2 A 100 - 110 50 - 60 N/A 5 8S 36 Canopy Connection
I.V. Pole
U.V. Light
30261xxx1 Logic+[1] [3] A2 A 100 - 110 50 - 60 N/A 6 10S 36 Canopy Connection
I.V. Pole
U.V. Light
30262xxx1 Logic+[3] [4] A2 A 100 - 110 50 - 60 N/A 6 12S 36 Canopy Connection
I.V. Pole
U.V. Light
30268xxx1 Logic+[1] [3] A2 A 100 - 110 50 - 60 N/A 6 8S 36 Canopy Connection
I.V. Pole
U.V. Light
30348xxx1 Logic+[1] [3] B2 A 100 - 110 50 - 60 852 @ 1.8 4 8S 36 Bag-In/ Bag-Out
I.V. Pole
U.V. Light
30368xxx1 Logic+[1] [3] B2 A 100 - 110 50 - 60 1265 @ 2.2 6 8S 36 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
30448xxx1 Axiom[3] [6] C1 A 100 - 110 60 - 70 N/A 4 8S 36 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
30441xxx1 Axiom[3] [6] C1 A 100 - 110 60 - 70 N/A 4 10S 36 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
30468xxx1 Axiom[3] [4] C1 A 100 - 110 50 - 60 N/A 6 8S 36 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
30461xxx1 Axiom[3] [6] C1 A 100 - 110 60 - 70 N/A 6 10S 36 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
31231xxx1 PuriCare[1] [2] A2 A 100 - 110 50 - 60 N/A 3 10S 36 I.V. Pole
U.V. Light
Canopy Connection
31241xxx1 PuriCare[1] [3] A2 A 100 - 110 50 - 60 N/A 4 10S 36 Canopy Connection
I.V. Pole
U.V. Light
31242xxx1 PuriCare[3] [4] A2 A 100 - 110 50 - 60 N/A 4 12S 36 I.V. Pole
U.V. Light
Canopy Connection
31251xxx1 PuriCare[1] [3] A2 A 100 - 110 50 - 60 N/A 5 10S 36 Canopy Connection
I.V. Pole
U.V. Light
31252xxx1 PuriCare[3] [7] A2 A 100 - 110 55 - 65 N/A 5 12S 36 Canopy Connection
I.V. Pole
U.V. Light
31261xxx1 PuriCare[1] [3] A2 A 100 - 110 50 - 60 N/A 6 10S 36 Canopy Connection
I.V. Pole
U.V. Light
31262xxx1 PuriCare[3] [4] A2 A 100 - 110 50 - 60 N/A 6 12S 36 Canopy Connection
I.V. Pole
U.V. Light

[1] Beginning with serial number 190500000.  Inflow nominal set point of 105 fpm was
    established with a direct airflow reading instrument.  This nominal set point was
    confirmed using the manufacturer's recommended alternate method with thermal anemometer
    in a constricted access opening, using the manufacturer-supplied probe holder and sash
    stop (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set point of 55 fpm was established
    with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2016.  This cabinet model is Certified for use with optional sidewall Vacu PassTM
    Cord & Cable Portal.
[2] Certified for use with power supplies of 230V/50 Hz and 230V/60 Hz.
[3] Certified for use with power supplies of 100V/50 Hz, 100V/60 Hz, 230V/50 Hz, and 230V/60
    Hz.
[4] Beginning with serial number 151200002.  Inflow nominal set point of 105 fpm was
    established with a direct airflow reading instrument. This nominal set point was
    confirmed using the manufacturer's recommended alternate method with thermal anemometer
    in a constricted access opening, using the manufacturer-supplied probe holder and sash
    stop (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set point of 60 fpm was established
    with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2014.  This cabinet model is Certified for use with optional sidewall Vacu-PassTM
    Cord & Cable Portal.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted access opening, using the
    manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
    correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
    nominal set point of 55 fpm was established with I.V. Pole and U.V. Light removed. This
    cabinet model was Certified to NSF/ANSI 49-2018.  This cabinet model is Certified for
    use with optional sidewall Vacu-PassTM Cord & Cable Portal.
[6] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted access opening, using the
    manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
    correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
    nominal set point of 60 fpm was established with I.V. Pole and U.V. Light removed. This
    cabinet model was Certified to NSF/ANSI 49-2018.  This cabinet model is Certified for
    use with optional sidewall Vacu-PassTM Cord & Cable Portal.
[7] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted access opening, using the
    manufacturer-supplied probe holder and sash stop (consult manufacturer for appropriate
    correction factor, if applicable), without adjusting cabinet airflow balance. Downflow
    nominal set point of 65 fpm was established with I.V. Pole and U.V. Light removed. This
    cabinet model was Certified to NSF/ANSI 49-2018.  This cabinet model is Certified for
    use with optional sidewall Vacu-PassTM Cord & Cable Portal.

NOTE: Bench stand models 3730300, 3730310, 3401003, 3780200 and 3780100 may be used with
      cabinets in the 30231xxx1/30238xxx1 Logic+ series. Bench stand models 3730400, 3730410,
      3401004, 3780201 and 3780101 may be used with cabinets in the 30241xxx1/30248xxx1/30242
      Logic+ series and the corresponding PuriCare series. Bench stand models 3730500,
      3730510, 3401005, 3780203, 3780106, 3780107, 3780312, and 3780316 may be used with
      cabinets in the 30251xxx1/30258xxx1 Logic+ series. Bench stand models 3730600, 3630610,
      3401006, 3780202 and 3780102 may be used with cabinets in the 30261xxx1/30268xxx1/30262
      Logic+ series and the corresponding PuriCare series.  Bench stand models 3730400 and
      34103003 may also be used with the 30348xxx1 Logic+ Series.  Bench stand models 3730600
      and 34103006 may also be used with the 30368xxx1 Logic+ Series.  All bench stand models
      beginning with 378 may be used with or without the optional wheel kit (PN# 3784000).


 
MEDFUTURE LLC 
3231 Osgood Common
Freemont, CA 94539 
United States 
626-283-4740
Visit this company's website
Facility : Shandong Province, China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
B-IIA2-2F-GL[1] A2 A 100 - 110 60 - 70 N/A 2 10S 28 U.V. Light
Canopy Connection
B-IIA2-2F-NA[1] A2 A 100 - 110 60 - 70 N/A 2 10S 28 U.V. Light
Canopy Connection
B-IIA2-4F[2] [3] A2 A 100 - 110 60 - 70 N/A 4 8S 27 I.V. Pole
U.V. Light
B-IIA2-4F-GL[4] A2 A 100 - 110 60 - 70 N/A 4 10S 27 I.V. Pole
U.V. Light
Canopy Connection
B-IIA2-4F-NA[4] A2 A 100 - 110 60 - 70 N/A 4 10S 27 I.V. Pole
U.V. Light
Canopy Connection
B-IIA2-6F-GL[5] A2 A 100 - 110 60 - 70 N/A 6 10S 27 I.V. Pole
U.V. Light
Canopy Connection
B-IIA2-6F-NA[5] A2 A 100 - 110 60 - 70 N/A 6 10S 27 I.V. Pole
U.V. Light
Canopy Connection

[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer's operator's manual for appropriate correction factor) without
    adjusting cabinet airflow balance. Downflow nominal set point of 65 fpm was established
    with U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2020. Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
    Canopy connection model number is 2A2T-CC.
[2] Approved for alternate power modes of 220V/50Hz and 220V/60Hz.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. A corresponding inflow nominal set point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance. The downflow nominal set
    point of 65 fpm was established 4 inches above the bottom of the sash with the I.V. Pole
    and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012.
[4] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance. The downflow nominal
    set-point of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
    Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
    Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.
[5] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance. The downflow nominal
    setpoint of 65 fpm was established 4 inches above the bottom of the sash with the I.V.
    Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.
    Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz.



 
Nuaire, Inc. 
2100 Fernbrook Lane
Plymouth, MN 55447 
United States 
763-553-1270
Visit this company's website
Facility : Plymouth, MN

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
NU-427-400[1] [2] [3] B1 A 100 - 110 65 - 75 282 @ 0.7 4 8S 32 Bag-In/ Bag-Out
I.V. Pole
U.V. Light
NU-427-600[1] [2] [4] B1 A 100 - 110 65 - 75 474 @ 0.9 6 8S 32 I.V. Pole
U.V. Light
Bag-In/ Bag-Out
NU-540-300[5] A2 A 100 - 110 55 - 65 N/A 3 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-300[5] A2 A 100 - 110 55 - 65 N/A 3 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-400[5] A2 A 100 - 110 55 - 65 N/A 4 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-400[5] A2 A 100 - 110 55 - 65 N/A 4 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-500[5] A2 A 100 - 110 57 - 67 N/A 5 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-500[5] A2 A 100 - 110 57 - 67 N/A 5 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-600[5] A2 A 100 - 110 55 - 65 N/A 6 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-540-600[5] A2 A 100 - 110 55 - 65 N/A 6 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-300[5] A2 A 100 - 110 55 - 65 N/A 3 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-300[5] A2 A 100 - 110 55 - 65 N/A 3 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-300[5] A2 A 100 - 110 55 - 65 N/A 3 12S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-400[5] A2 A 100 - 110 55 - 65 N/A 4 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-400[5] A2 A 100 - 110 55 - 65 N/A 4 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-400[5] A2 A 100 - 110 55 - 65 N/A 4 12S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-500[5] A2 A 100 - 110 57 - 67 N/A 5 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-500[5] A2 A 100 - 110 57 - 67 N/A 5 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-500[5] A2 A 100 - 110 57 - 67 N/A 5 12S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-600[5] A2 A 100 - 110 55 - 65 N/A 6 8S 35 U.V. Light
I.V. Pole
Canopy Connection
NU-543-600[5] A2 A 100 - 110 55 - 65 N/A 6 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-543-600[5] A2 A 100 - 110 55 - 65 N/A 6 12S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-300[6] A2 A 100 - 110 55 - 65 N/A 3 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-300[6] A2 A 100 - 110 55 - 65 N/A 3 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-400[7] A2 A 100 - 110 55 - 65 N/A 4 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-400[7] A2 A 100 - 110 55 - 65 N/A 4 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-500[8] A2 A 100 - 110 55 - 65 N/A 5 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-500[8] A2 A 100 - 110 55 - 65 N/A 5 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-600[9] A2 A 100 - 110 55 - 65 N/A 6 8S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-545-600[9] A2 A 100 - 110 55 - 65 N/A 6 10S 35 I.V. Pole
U.V. Light
Canopy Connection
NU-560-400[10] B2 A 100 - 110 55 - 65 859@1.8 4 8S 36 I.V. Pole
U.V. Light
NU-560-600[11] B2 A 100 - 110 55 - 35 1373@2.0 6 8S 36 I.V. Pole
U.V. Light
NU-565-400[10] B2 A 100 - 110 55 - 65 859@1.8 4 8S 36 I.V. Pole
U.V. Light
NU-565-600[11] B2 A 100 - 110 55 - 65 1373@2.0 6 8S 36 I.V. Pole
U.V. Light
NU-677-400[12] A2 A 100 - 110 55 - 65 N/A 4 12S 38 Canopy Connection
U.V. Light
NU-677-500[13] A2 A 100 - 110 55 - 65 N/A 5 12S 38 Canopy Connection
U.V. Light
NU-677-600[14] A2 A 100 - 110 55 - 65 N/A 6 12S 38 Canopy Connection
U.V. Light
NU-FH677-500[15] A2 A 100 - 110 55 - 65 N/A 5 12S 38 U.V. Light

[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening for appropriate correction
    factor, if applicable, without adjusting cabinet airflow balance.
[2] Listed model may be suffixed with E. Certified for use with power supplies of 230V/50Hz
    and 230V/60Hz.
[3] Beginning with Series 60 and higher.  Downflow nominal set-point of 70 fpm was
    established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
    removed.  This cabinet model was Certified to NSF/ANSI 49-2011.  This cabinet qualifies
    with the optional DC motor installed.  Listed model may be prefaced with Q, N, L or S
    (i.e. NU-Q427-400).
[4] Beginning with series 40 and higher.  Downflow nominal set-point of 60 fpm was
    established 4 inches above the plane of the window with the I.V. Pole and U.V. Light
    removed.  This cabinet qualifies with the optional DC motor installed.
    Listed model may be prefaced with Q, N, L or S (i.e. NU-Q427-600).  This cabinet model
    was Certified to NSF/ANSI 49-2011.
[5] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal
    set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V.
    Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2012.
    Listed model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300).  Certified for use
    with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz.
[6] Beginning with serial number 170844102115.  Inflow nominal set-point of 105 fpm was 
    established with a direct airflow reading instrument.  A corresponding inflow nominal 
    set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
    
    recommended alternate method with thermal anemometer in a constricted (3 inch high) 
    access opening and applying appropriate correction factor without adjusting cabinet
    airflow balance.  The downflow nominal set-point of 60 fpm was established 4 inches
    above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
    model was 
    Certified to NSF/ANSI 49-2014.  Listed model may be prefaced with Q, N, L, or S 
    (e.g. NU-Q540-300).  Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 
    230V/50Hz, and 230V/60Hz.
    
[7] Beginning with serial number 170847102115.   Inflow nominal set-point of 105 fpm was
    established with a direct airflow reading instrument. A corresponding inflow nominal
    set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
     recommended alternate method with thermal anemometer in a constricted (3 inch high)
    access opening and applying appropriate correction factor without adjusting cabinet
    airflow balance. The downflow nominal set-point of 60 fpm was established 4 inches above
    the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was
    Certified to NSF/ANSI 49-2020.  Listed model may be prefaced with Q, N, L, or S (e.g.
    NU-Q540-300).  Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 230V/50Hz,
    and 230V/60Hz.
[8] Beginning with serial number 170845102115.  Inflow nominal set-point of 105 fpm was
    established with a direct airflow reading instrument.  A corresponding inflow nominal
    set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
    recommended alternate method with thermal anemometer in a constricted (3 inch high)
    access opening and applying appropriate correction factor without adjusting cabinet
    airflow balance.  The downflow nominal set-point of 60 fpm was established 4 inches
    above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
    model was Certified to NSF/ANSI 49-2014.  Listed model may be prefaced with Q, N, L, or
    S (e.g. NU-Q540-300).  Certified for use with power supplies of 100V/50Hz, 100V/60Hz,
    230V/50Hz, and 230V/60Hz.
    
[9] Beginning with serial number 170846102115.  Inflow nominal set-point of 105 fpm was 
    established with a direct airflow reading instrument.  A corresponding inflow nominal 
    set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
    
    recommended alternate method with thermal anemometer in a constricted (3 inch high) 
    access opening and applying appropriate correction factor without adjusting cabinet
    airflow 
    balance.  The downflow nominal set-point of 60 fpm was established 4 inches above the 
    bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet model was 
    Certified to NSF/ANSI 49-2014.  Listed model may be prefaced with Q, N, L, or S 
    (e.g. NU-Q540-300).  Certified for use with power supplies of 100V/50Hz, 100V/60Hz, 
    230V/50Hz, and 230V/60Hz.
    
[10] Beginning with serial number 179773041817.  Inflow nominal set-point of 105 fpm was
     established with a direct airflow reading instrument.  A corresponding inflow nominal
     set-point of 105 fpm (corrected to local air density) was confirmed using manufacturer's
     recommended alternate method with thermal anemometer in a constricted (3 inch high)
     access opening and applying appropriate correction factor without adjusting cabinet
     airflow balance.  The downflow nominal set-point of 60 fpm was established 4 inches
     above the bottom of the sash with the I.V. Pole and U.V. Light removed. This cabinet
     model was Certified to NSF/ANSI 49-2016.  Certified for use with power supplies of
     115V/60Hz, 230V/50Hz and 230V/60Hz. The concurrent balance value was taken with the NSF
     exhaust system conforming to ASHRAE. However, differences due to the	exhaust system,
     cabinet and instrumentation may be present and product specification information should
     be obtained from the manufacturer.									
     
[11] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
     instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
     density) was	confirmed using manufacturer's recommended alternate method with thermal
     anemometer in a constricted (3 inch high) access opening and applying appropriate
     correction factor without adjusting cabinet airflow balance.  The downflow nominal
     set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V.
     Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI 49-2016. 
     Certified for use with power supplies of 115V/60Hz, 230V/50Hz and 230V/60Hz. The
     concurrent balance value was taken with the NSF exhaust system conforming to ASHRAE.
     However, differences due to the exhaust system, cabinet and instrumentation may be
     present and product specification information should be obtained from the
     manufacturer.								
     
[12] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
     instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
     density) was confirmed using manufacturer's recommended alternate method with thermal
     anemometer in a constricted (3 inch high) access opening and applying appropriate
     correction factor without adjusting cabinet airflow balance.  The downflow nominal
     set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
     Light removed.  This cabinet model was Certified to NSF/ANSI 49-2011.  NuAire canopy
     model NU-911-402 was evaluated as part of the NSF Certification testing procedures.
     
[13] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
     instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
     density) was confirmed using manufacturer's recommended alternate method with thermal
     anemometer in a constricted (3 inch high) access opening and applying appropriate
     correction factor without adjusting cabinet airflow balance.  The downflow nominal
     set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
     Light removed.  This cabinet model was Certified to NSF/ANSI 49-2011.  NuAire canopy
     model NU-911-502 was evaluated as a part of the NSF Certification testing procedures.
[14] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
     instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
     density) was confirmed using manufacturer's recommended alternate method with thermal
     anemometer in a constricted (3 inch high) access opening and applying appropriate
     correction factor without adjusting cabinet airflow balance.  The downflow nominal
     set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
     Light removed.  This cabinet model was Certified to NSF/ANSI 49-2011.  NuAire canopy
     model NU-911-602 was evaluated as part of the NSF Certification testing procedures.
[15] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
     instrument. A corresponding inflow nominal set-point of 105 fpm (corrected to local air
     density) was confirmed using manufacturer's recommended alternate method with thermal
     anemometer in a constricted (3 inch high) access opening and applying appropriate
     correction factor without adjusting cabinet airflow balance. The downflow nominal
     set-point of 60 fpm was established 4 inches above the bottom of the sash with the U.V.
     Light removed. This cabinet model was Certified to NSF/ANSI 49-2012. NuAire canopy model
     NU-911-502 was evaluated as a part of the NSF Certification testing procedures.
     NU-FH677-500 is a modified version of NU-677-500, including feed hoppers.

Facility : Shanghai, China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
NU-543-300[1] A2 A 100 - 110 55 - 65 N/A 3 10S 35 Canopy Connection
I.V. Pole
U.V. Light
NU-543-400[1] A2 A 100 - 110 55 - 65 N/A 4 10S 35 Canopy Connection
I.V. Pole
U.V. Light
NU-543-500[2] A2 A 100 - 110 57 - 67 N/A 5 10S 35 Canopy Connection
I.V. Pole
U.V. Light
NU-543-600[1] A2 A 100 - 110 55 - 65 N/A 6 10S 35 Canopy Connection
I.V. Pole
U.V. Light

[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal
    set-point of 60 fpm was established 4 inches above the bottom of the sash with the I.V.
    pole and U.V. light removed.  This cabinet model was Certified to NSF 49-2012. Listed
    model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300).  Listed model may be
    suffixed with J, K, or S (e.g. NU-543-400S).  Certified for use with power supplies of
    100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz.
[2] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (3 inch high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal
    set-point of 62 fpm was established 4 inches above the bottom of the sash with the I.V.
    pole and U.V. light removed.  This cabinet model was Certified to NSF 49-2012.  Listed
    model may be prefaced with Q, N, L, or S (e.g. NU-Q540-300).  Listed model may be
    suffixed with J, K, or S (e.g. NU-543-400S).  Certified for use with power supplies of
    100V/50Hz, 100V/60Hz, 230V/50Hz, and 230V/60Hz.



 
Qingdao Haier Biomedical Co., Ltd. 
No. 280 Fengyuan Road
High-Tech Zone 
Qingdao 266111 
China 
86 176 6092 6003
Visit this company's website
Facility : Qingdao, China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
HR900-IIA2-N[1] [2] A2 A 100 - 110 64 - 74 N/A 3 8S 27 U.V. Light
Casters
Hgt Adjustable Stand
HR1200-IIA2-N[1] [3] A2 A 100 - 110 64 - 74 N/A 4 8S 27 U.V. Light
Casters
Hgt Adjustable Stand
HR1800-IIA2-N[1] [4] A2 A 100 - 110 65 - 75 N/A 6 8S 27 U.V. Light
Casters
Hgt Adjustable Stand

[1] This cabinet model was Certified for use with power supplies of 100V/60Hz, 115V/60Hz,
    230V/50Hz, 230V/60Hz
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted access opening (consult
    manufacturer for appropriate correction factor, if applicable), without adjusting
    cabinet airflow balance. Downflow nominal set point of 69 fpm was established U.V. Light
    removed. This cabinet is Certified to NSF/ANSI 49-2022. GFCI outlet is approved for this
    model.
[3] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted access opening (consult
    manufacturer for appropriate correction factor, if applicable), without adjusting
    cabinet airflow balance. Downflow nominal set point of 69 fpm was established U.V. Light
    removed.
    This cabinet is Certified to NSF/ANSI 49-2019. GFCI outlet is approved for this model. 
[4] Beginning with serial number BE0GGBEB200QHM7P0001. Inflow nominal set point of 105 fpm
    was established with a direct airflow reading instrument. This nominal set point was
    confirmed using the manufacturer's recommended alternate method with thermal anemometer
    in a constricted access opening (consult manufacturer for appropriate correction factor,
    if applicable), without adjusting cabinet airflow balance. Downflow nominal set point of
    70 fpm was established U.V. Light removed. This cabinet is Certified to NSF/ANSI 49-2019.



 
Suzhou Antai Airtech Co., Ltd. 
No. 2 Weixin Road, SIP
Suzhou, Jiangsu 215122 
China 
86 512 6552 5002
Visit this company's website
Facility : Suzhou, Jiangsu, China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
BSC-1301 II A2[1] A2 A 100 - 110 64 - 74 N/A 4 10S 24 U.V. Light
Canopy Connection
BSC-1302 II A2[1] [2] A2 A 100 - 110 64 - 74 N/A 4 10S 24 U.V. Light
Canopy Connection

[1] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  A corresponding inflow nominal set-point of 105 fpm (corrected to local air
    density) was confirmed using manufacturer's recommended alternate method with thermal
    anemometer in a constricted (80 mm high) access opening and applying appropriate
    correction factor without adjusting cabinet airflow balance.  The downflow nominal
    set-point of 69 fpm was established 4 inches above the bottom of the sash with the U.V.
    Light removed. This cabinet model was Certified to NSF/ANSI 49-2014.  Approved metric
    value for cabinet width is 1270 mm, window height is 250 mm, and bench height max is 610
    mm.
[2] Certified for use with power supplies of 230V/50Hz and 230V/60Hz.



 
Thermo Fisher Scientific 
Robert-Bosch-Str. 1
D-63505 Langenselbold 
Germany 
49 61 813 5277
Visit this company's website
Facility : # 1 Suzhou, China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
1304[1] [2] A2 A 100 - 110 58 - 68 N/A 4 8S 36 Armrest
I.V. Pole
U.V. Light
1309[1] [2] A2 A 100 - 110 58 - 68 N/A 6 8S S Armrest
I.V. Pole
U.V. Light
1374[1] [2] [3] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1379[1] [2] [4] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1384[1] [2] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1389[1] [2] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1394[1] [2] A2 A 100 - 110 58 - 68 N/A 4 8S 36 Armrest
I.V. Pole
U.V. Light
1399[1] [2] A2 A 100 - 110 58 - 68 N/A 6 8S 36 Armrest
I.V. Pole
U.V. Light
1574[5] [6] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1579[5] [6] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1584[5] [7] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1589[5] [7] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light

[1] Models can be provided with Type F power cord and internal receptacles and identified as
    1304-F, 1309-F, 1374-F, 1379-F, 1384-F, 1389-F, 1394-F, or 1399-F; with Type G power
    cord
    and internal receptacles and identified as 1304-G, 1309-G, 1374-G, 1379-G, 1384-G, 1389-
    G, 1394-G, or 1399-G; with Type M power cord and internal receptacles and identified as
    1304-M, 1309-M, 1374-M, 1379-M, 1384-M, 1389-M, 1394-M, or 1399-M; or with the standard
    Type I power cord and internal receptacles.
[2] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set-point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established
    with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2014. Certified for use with power supplies of 220V/50Hz and 220V/60Hz.
[3] Beginning with serial number 1374318010704.
[4] Beginning with serial number 1379318010304.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set-point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was
    established with I.V. Pole and U.V. Light removed. This cabinet model was Certified
    to NSF/ANSI 49-2020. Certified for use with power supplies of 230V/50Hz and 230V/60Hz.
    Removable armrests with padded and non-padded designs in addition to dished and flat
    work surface designs are approved options for this cabinet model.
[6] This model includes stainless steel interior cabinet walls with adjustable height
    stand. Model can be provided with the standard Type I power cord and internal
    receptacles (China electrical configuration with YY certification) and identified as
    1574, and 1579; with Type GP power cord and internal receptacles (China electrical
    configuration without YY certification) and identified as 1574-GP, 1579-GP; with Type
    F power cord and internal receptacles (Korea electrical configuration) and identified
    as 1574-F, 1579-F; with Type G power cord and internal receptacles (UK electrical
    configuration) and identified as 1574-G, 1579-G; with Type M power cord and internal
    receptacles (India electrical configuration) and identified as 1574-M, 1579-M; or with
    Type C fixed height stand with castors and identified as 1574-C, 1579-C, 1574-FC,
    1579-FC, 1574-GC, 1579-GC, 1574-MC, 1579-MC, 1574-C-GP, 1579-C-GP. 1546 and 1548 are
    the same models as 1574 and 1579 without stands.
[7] This model includes coated steel (SmartCoat)interior cabinet walls with adjustable
    height stand. Model can be provided with the standard Type I power cord and internal
    receptacles (China electrical configuration with YY certification) and identified as
    1584, 1589; with Type F power cord and internal receptacles (Korea electrical
    configuration)and identified as 1584-F, 1589-F; with Type G power cord and internal
    receptacles (UK electrical configuration) and identified as 1584-G, 1589-G; with Type
    M power cord and internal receptacles (India electrical configuration) and identified
    as 1584-M, 1589-M; or with Type C fixed height stand with castors and identified as
    1584-C, 1589-C, 1584-FC, 1589-FC, 1584-GC, 1589-GC, 1584-MC, 1589-MC. 1556 and 1558
    are the same models as 1584 and 1589 without stands.

Facility : # 2 Suzhou, China

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
1574[1] [2] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1579[1] [2] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1584[1] [3] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1589[1] [3] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light

[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set-point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established
    with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/
    ANSI 49-2020. Certified for use with power supplies of 230V/50Hz and 230V/60Hz.
    Removable armrests with padded and non-padded designs in addition to dished and flat
    work surface designs are approved options for this cabinet model.
[2] This model includes stainless steel interior cabinet walls with adjustable height stand.
    Model can be provided with the standard Type I power cord and internal receptacles
    (China electrical configuration with YY certification) and identified as 1574, and 1579;
    with Type GP power cord and internal receptacles (China electrical configuration
    without YY certification) and identified as 1574-GP, 1579-GP; with Type F power cord and
    internal receptacles (Korea electrical configuration) and identified as 1574-F,
    1579-F; with Type G power cord and internal receptacles (UK electrical configuration)
    and identified as 1574-G, 1579-G; with Type M power cord and internal receptacles
    (India electrical configuration) and identified as 1574-M, 1579-M; or with Type C fixed
    height stand with castors and identified as 1574-C, 1579-C, 1574-FC, 1579-FC,
    1574-GC, 1579-GC, 1574-MC, 1579-MC, 1574-C-GP, 1579-C-GP. 1546 and 1548 are the same
    models as 1574 and 1579 without stands.
[3] This model includes coated steel (SmartCoat)interior cabinet walls with adjustable
    height stand. Model can be provided with the standard Type I power cord and internal
    receptacles (China electrical configuration with YY certification) and identified as
    1584, 1589; with Type F power cord and internal receptacles (Korea electrical
    configuration)and identified as 1584-F, 1589-F; with Type G power cord and internal
    receptacles (UK electrical configuration) and identified as 1584-G, 1589-G; with Type
    M power cord and internal receptacles (India electrical configuration) and identified as
    1584-M, 1589-M; or with Type C fixed height stand with castors and identified as
    1584-C, 1589-C, 1584-FC, 1589-FC, 1584-GC, 1589-GC, 1584-MC, 1589-MC. 1556 and 1558 are
    the same models as 1584 and 1589 without stands.

Facility : Marietta, OH

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
1305[1] [2] A2 A 100 - 110 58 - 68 N/A 4 8S 36 Armrest
I.V. Pole
U.V. Light
1306[1] [2] [3] A2 A 100 - 110 58 - 58 N/A 4 8S 36 Armrest
I.V. Pole
U.V. Light
1307[1] [4] A2 A 100 - 110 58 - 68 N/A 6 8S 36 Armrest
I.V. Pole
U.V. Light
1308[1] [3] [4] A2 A 100 - 110 58 - 68 N/A 6 8S 36 Armrest
I.V. Pole
U.V. Light
1320[5] [6] [7] A2 B 100 - 110 58 - 68 N/A 3 10S 36 Armrest
I.V. Pole
U.V. Light
1321[5] [6] [7] A2 A 100 - 110 58 - 68 N/A 3 10S 36 Armrest
I.V. Pole
U.V. Light
1322[5] [6] [7] A2 B 100 - 110 58 - 68 N/A 3 10S 36 Armrest
I.V. Pole
U.V. Light
1323[5] [6] [7] A2 A 100 - 110 58 - 68 N/A 3 10S 36 Armrest
U.V. Light
I.V. Pole
1325[1] [2] A2 A 100 - 110 58 - 68 N/A 4 8S 36 Armrest
I.V. Pole
U.V. Light
1326[1] [2] [3] A2 A 100 - 110 58 - 68 N/A 4 8S 36 Armrest
I.V. Pole
U.V. Light
1327[1] [4] A2 A 100 - 110 58 - 68 N/A 6 8S 36 Armrest
I.V. Pole
U.V. Light
1328[1] [3] [4] A2 A 100 - 110 58 - 68 N/A 6 8S 36 Armrest
I.V. Pole
U.V. Light
1330[3] [5] [6] [7] A2 B 100 - 110 58 - 68 N/A 3 10S 36 Armrest
I.V. Pole
U.V. Light
1331[3] [5] [6] [7] A2 A 100 - 110 58 - 68 N/A 3 10S 36 Armrest
I.V. Pole
U.V. Light
1332[3] [5] [6] [7] A2 B 100 - 110 58 - 68 N/A 3 10S 36 Armrest
I.V. Pole
U.V. Light
1333[3] [5] [6] [7] A2 A 100 - 110 58 - 68 N/A 3 10S 36 Armrest
I.V. Pole
U.V. Light
1335[1] [2] A2 A 100 - 110 58 - 68 N/A 4 8S 36 Armrest
I.V. Pole
U.V. Light
1336[1] [2] [3] A2 A 100 - 110 58 - 68 N/A 4 8S 36 Armrest
I.V. Pole
U.V. Light
1337[1] [4] A2 A 100 - 110 58 - 68 N/A 6 8S 36 Armrest
I.V. Pole
U.V. Light
1338[1] [3] [4] A2 A 100 - 110 58 - 68 N/A 6 8S 36 Armrest
I.V. Pole
U.V. Light
1339[5] [6] [7] A2 B 100 - 110 58 - 68 N/A 3 8S 36 Armrest
I.V. Pole
U.V. Light
1340[5] [6] [7] A2 A 100 - 110 58 - 68 N/A 3 8S 36 Armrest
I.V. Pole
U.V. Light
1341[5] [6] [7] A2 B 100 - 110 58 - 68 N/A 3 8S 36 Armrest
I.V. Pole
U.V. Light
1342[5] [6] [7] A2 A 100 - 110 58 - 68 N/A 3 8S 36 Armrest
I.V. Pole
U.V. Light
1345[2] [8] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1346[2] [8] [9] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1347[4] [8] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1348[4] [8] [9] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1350[5] [6] [10] A2 B 100 - 110 58 - 68 N/A 5 8S 36 Armrest
I.V. Pole
U.V. Light
1351[5] [6] [10] A2 A 100 - 110 58 - 68 N/A 5 8S 36 Armrest
I.V. Pole
U.V. Light
1352[5] [6] [10] A2 B 100 - 110 58 - 68 N/A 5 8S 36 Armrest
I.V. Pole
U.V. Light
1353[5] [6] [10] A2 A 100 - 110 58 - 68 N/A 5 8S 36 Armrest
I.V. Pole
U.V. Light
1354[2] [11] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1355[2] [8] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1356[2] [8] [9] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1357[4] [8] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1358[4] [8] [9] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1359[4] [8] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1366[3] [5] [6] [10] A2 B 100 - 110 58 - 68 N/A 5 8S 36 Armrest
I.V. Pole
U.V. Light
1367[3] [5] [6] [10] A2 A 100 - 110 58 - 68 N/A 5 8S 36 Armrest
I.V. Pole
U.V. Light
1368[5] [6] [10] A2 B 100 - 110 58 - 68 N/A 5 10S 36 Armrest
I.V. Pole
U.V. Light
1369[5] [6] [10] A2 A 100 - 110 58 - 68 N/A 5 10S 36 Armrest
U.V. Light
I.V. Pole
1370[5] [6] [10] A2 B 100 - 110 58 - 68 N/A 5 10S 36 Armrest
I.V. Pole
U.V. Light
1371[5] [6] [10] A2 A 100 - 110 58 - 68 N/A 5 10S 36 Armrest
I.V. Pole
U.V. Light
1372[3] [5] [6] [10] A2 B 100 - 110 58 - 68 N/A 5 8S 36 Armrest
U.V. Light
I.V. Pole
1373[3] [5] [6] [10] A2 A 100 - 110 58 - 68 N/A 5 8S 36 Armrest
I.V. Pole
U.V. Light
1375[2] [8] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1376[2] [8] [9] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1377[4] [8] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1378[4] [8] [9] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1380[3] [5] [6] [10] A2 B 100 - 110 58 - 68 N/A 5 10S 36 Armrest
I.V. Pole
U.V. Light
1381[3] [5] [6] [10] A2 A 100 - 110 58 - 68 N/A 5 10S 36 Armrest
I.V. Pole
U.V. Light
1382[3] [5] [6] [10] A2 B 100 - 110 58 - 68 N/A 5 10S 36 Armrest
I.V. Pole
U.V. Light
1383[3] [5] [6] [10] A2 A 100 - 110 58 - 68 N/A 5 10S 36 Armrest
I.V. Pole
U.V. Light
1384[2] [11] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1385[2] [8] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1386[2] [8] [9] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
1387[4] [8] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1388[4] [8] [9] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1389[4] [11] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light
1390[3] [5] [6] [7] A2 B 100 - 110 58 - 68 N/A 3 8S 36 Armrest
I.V. Pole
U.V. Light
1391[3] [5] [6] [7] A2 A 100 - 110 58 - 68 N/A 3 8S 36 Armrest
I.V. Pole
U.V. Light
1392[3] [5] [6] [7] A2 B 100 - 110 58 - 68 N/A 3 8S 36 Armrest
I.V. Pole
U.V. Light
1393[3] [5] [6] [7] A2 A 100 - 110 58 - 68 N/A 3 8S 36 Armrest
I.V. Pole
U.V. Light
1395[2] [9] [12] A2 A 100 - 110 58 - 68 N/A 4 8S 36 Armrest
I.V. Pole
U.V. Light
1396[1] [2] [3] A2 A 100 - 110 58 - 68 N/A 4 8S 36 Armrest
I.V. Pole
U.V. Light
1397[4] [9] [12] A2 A 100 - 110 58 - 68 N/A 6 8S 36 Armrest
I.V. Pole
U.V. Light
1398[1] [3] [4] A2 A 100 - 110 58 - 68 N/A 6 8S 36 Armrest
I.V. Pole
U.V. Light

[1] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument. This nominal set-point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set-point of 63 fpm was established
    with I.V. Pole and U.V. Light removed. This cabinet model was Certified to NSF/ANSI
    49-2009.
[2] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height
    base stand GT221189 along with 4ft cross brace GT221195 were approved for use with all
    1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option
    for both stands.
[3] Certified for use with power supply of 230V/50Hz and 230V/60Hz.
[4] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height
    base stand GT221189 along with 6ft cross brace GT221196 were approved for use with all
    1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option
    for both stands.
[5] Inflow nominal set point of 105 fpm was established with a direct airflow reading
    instrument.  This nominal set point was confirmed using the manufacturer's alternate
    recomended method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer's operator's manual for appropriate correction factor), without
    adjusting cabinet airflow balance.  Downflow nominal set point was established with
    I.V.Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI 49-2009.
[6] May be used with alternate, adjustable height electric stand (maximum bench height of 35
    inches).
[7] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height
    base stand GT221189 along with 3ft cross brace GT221193 were approved for use with all
    1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option
    for both stands.
[8] Inflow nominal set-point of 105 fpm was established with a direct airflow reading
    instrument.  This nominal set point was confirmed using the manufacturer's recommended
    alternate method with thermal anemometer in a constricted (3 inch high) access opening
    (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance.  Downflow nominal set point of 63 fpm was established
    with I.V. Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI
    49-2009. Certified for use with power supply of 230V/50Hz and 230V/60Hz.
[9] Certified for use with power supply of 220 V / 50 Hz and 220 V / 60 Hz.
[10] Beginning April 20, 2020 a new fixed height base stand GT221201 and adjustable height
     base stand GT221189 along with 5ft cross brace GT221197 were approved for use with all
     1300 series models manufactured in Marietta OH. Casters GT221199 is an approved option
     for both stands.
[11] Inflow nominal set point of 105 fpm was established with a direct airflow reading
     instrument.  This nominal set-point was confirmed using the manufacturer's recommended
     alternate method with thermal anemometer in a constricted (3 inch high) access opening
     (consult manufacturer for appropriate correction factor, if applicable), without
     adjusting cabinet airflow balance.  Downflow nominal set-point of 63 fpm was established
     with I.V. Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI
     49-2009.  Certified for use with power supply of 220V/50Hz.
[12] Beginning with serial number 188122-1 and 188108-1 for models 1395 and 1397,
     respectively.  Inflow nominal set-point of 105 fpm was established with a direct airflow
     reading instrument. This nominal set point was confirmed using the manufacturer's
     recommended alternate method with thermal anemometer in a constricted (3 inch high)
     access opening (consult manufacturer for appropriate correction factor, if applicable),
     without adjusting cabinet airflow balance. Downflow nominal set point of 63 fpm was
     established with I.V. Pole and U.V. Light removed. This cabinet model was Certified to
     NSF/ANSI 49-2009.

Facility : Langenselbold, Germany

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
HERAsafe 2030i 1.2[1] A2 A 100 - 110 58 - 68 N/A 4 10S 36 Armrest
I.V. Pole
U.V. Light
HERAsafe 2030i 1.8[1] A2 A 100 - 110 58 - 68 N/A 6 10S 36 Armrest
I.V. Pole
U.V. Light

[1] Beginning with serial number 42294669 for the HERAsafe 2030i 1.2 and serial number
    42209172 for the HERAsafe 2030i 1.8.  Inflow nominal set point of 105 fpm was
    established with a direct airflow reading instrument.  This nominal set point was
    confirmed using the manufacturer's recommended alternate method with thermal anemometer
    in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
    for appropriate correction factor) without adjusting cabinet airflow balance. Downflow
    nominal set point of 63 fpm was established with I.V. Pole and U.V. Light removed.  This
    cabinet model was Certified with both dished and flat work surfaces and for additional
    inlet power supplies of 230V/50Hz and 230V/60Hz.  This cabinet model was Certified to
    NSF/ANSI 49-2018.  HERAsafe 2030i 1.2 is approved for use with either padded armrests or
    armrests without padding.  HERAsafe 2030i 1.8 is approved for use without armrests, with
    padded armrests, or with armrests without padding.

[2] Beginning with serial number 40329642.  Inflow nominal set-point of 105 fpm was
    established with a direct airflow reading instrument.  This nominal set-point was
    confirmed using the manufacturer's recommended alternate method with thermal anemometer
    in a constricted (3 inch high) access opening (consult manufacturer's operator's manual
    for appropriate correction factor) without adjusting cabinet airflow balance. This
    cabinet model was Certified with a 3 section work surface. This cabinet model was
    Certified to NSF/ANSI 49-2009.


 
Thermo Fisher Scientific 
401 Millcreek Road
Marietta, OH 45750 
United States 
740-373-4763
Facility : # 1 USA

Model
Number
Cabinet
Type/Style
Inflow
Velocity
(fpm)
Downflow
Velocity
(fpm)
CBV (cfm)
at Static
Pressure
(in w.g.)
Cabinet
Width
ft.
Window
Ht/Type
in.
Bench
Ht
Max
in.
Acceptable
Options
 
151x[1] [2] [3] B2 A 100 - 110 50 - 60 852 @ 1.8 4 8S 36 Bag-In/ Bag-Out
I.V. Pole
U.V. Light
156x[1] [2] [4] B2 A 100 - 110 50 - 60 1265 @ 2.2 6 8S 36 Bag-In/ Bag-Out
I.V. Pole
U.V. Light

[1] Beginning with serial number 190500000. Inflow nominal set point of 105 fpm was
    established with a direct airflow reading instrument.  This nominal set point was
    confirmed using the manufacturer's recommended alternate method with thermal anemometer
    in a constricted access opening, using the manufacturer-supplied probe holder and sash
    stop (consult manufacturer for appropriate correction factor, if applicable), without
    adjusting cabinet airflow balance. Downflow nominal set point of 55 fpm was established
    with I.V. Pole and U.V. Light removed.  This cabinet model was Certified to NSF/ANSI
    49-2016.  This cabinet model is Certified for use with optional cord & cable portal.
[2] Certified for use with power supplies of 100V/50 Hz, 100V/60 Hz, 230V/50 Hz, and 230V/60
    Hz.
[3] Model 1511 is equivalent to Model 1510, but comes equipped with U.V. lighting (Listed as
    an acceptable option).  Model 1515 is equivalent to model 1510, but is rated for use
    with power supplies of 230V and 50/60 Hz and is equipped with a Chinese-compatible plug.
     Model 1516 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz
    and is equipped with U.V. lighting and a Chinese-compatible plug. Model 1517 is
    equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is
    equipped with a North American 230 Volt-compatible plug. Model 1517F is equivalent, but
    is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type F
    electrical plug (Schuko).  Model 1517G is equivalent, but is rated for use with power
    supplies of 230V and 50/60 Hz and is equipped with a Type G electrical plug
    (UK-compatible). Model 1517M is equivalent, but is rated for use with power supplies of
    230V and 50/60 Hz and is equipped with a Type M electrical plug (India-compatible). 
    Model 1518 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz
    and is equipped with U.V. lighting and a North American 230 Volt-compatible plug.Model
    1518F is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and
    is equipped with a Type F electrical plug (Schuko).  Model 1518G is equivalent, but is
    rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type G
    electrical plug (UK-compatible).  Model 1518M is equivalent, but is rated for use with
    power supplies of 230V and 50/60 Hz and is equipped with a Type M electrical plug
    (India-compatible).
[4] Model 1561 is equivalent to Model 1560, but comes equipped with U.V. lighting (Listed as
    an acceptable option).  Model 1562 is equivalent to model 1560, but is rated for use
    with power supplies of 230V and 50/60 Hz and is equipped with a Chinese-compatible plug.
     Model 1563 is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz
    and is equipped with U.V. lighting and a Chinese-compatible plug. Model 1564 is
    equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and is
    equipped with a North American 230 Volt-compatible plug.  Model 1564F is equivalent, but
    is rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type F
    electrical plug (Schuko).  Model 1564G is equivalent, but is rated for use with power
    supplies of 230V and 50/60 Hz and is equipped with a Type G electrical plug
    (UK-compatible).  Model 1564M is equivalent, but is rated for use with power supplies of
    230V and 50/60 Hz and is equipped with a Type M electrical plug (India-compatible).
    Model 1565 is equivalent, but is rated for use with power supplies of 230 V and 50/60 Hz
    and is equipped with U.V. lighting and a North American 230 Volt-compatible plug. Model
    1565F is equivalent, but is rated for use with power supplies of 230V and 50/60 Hz and
    is equipped with a Type F electrical plug (Schuko). Model 1565G is equivalent, but is
    rated for use with power supplies of 230V and 50/60 Hz and is equipped with a Type G
    electrical plug (UK-compatible).  Model 1565M is equivalent, but is rated for use with
    power supplies of 230V and 50/60 Hz and is equipped with a Type M electrical plug
    (India-compatible).


Number of matching Manufacturers is 17
Number of matching Products is 346
Processing time was 0 seconds