These NSF Official Listings are current as of Sunday, September 05, 2010 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://www.nsf.org/Certified/DWTU/Listings.asp?Standard=053&Company=10190&
Note: Certain claims, such as Arsenic (Pentavalent) Reduction, appear as active links, allowing you to access additional information regarding the specific contaminants.
NSF/ANSI STANDARD 053
Drinking Water Treatment Units - Health Effects
Drinking Water Treatment Units - Health Effects
| Regal Ware, Inc. | ![]() |
| 1675 Reigle Drive | |
| Kewaskum, WI 53040 | |
| United States | |
| 262-334-2311 | |
| Visit this company's website |
Facility : West Bend, WI
| Replacement | Service Cycle | Flow Rate | ||||
| Brand Name / Trade Name / Model | Element | (gallons) | (gpm) | Claim | ||
|
Counter-Top Connected to Sink Faucet |
||||||
| K6842A | KSA1254 | 1000(1) | .7 | Lead Reduction Turbidity Reduction VOC Reduction |
||
| K6845 | KSA1255 | 1000(1) | .7 | Lead Reduction Cyst Reduction Turbidity Reduction VOC Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. |
||||||
|
Plumbed-In to Separate Tap |
||||||
| K6843B | KSA1254 | 1000(1) | .7 | Lead Reduction Turbidity Reduction VOC Reduction |
||
| K6844 | KSA1255 | 1000(1) | .7 | Lead Reduction Cyst Reduction Turbidity Reduction VOC Reduction |
||
|
  (1) Claims of capacity or rated service cycle are not applicable for mechanical filtration. |
||||||
NOTE: All replacement elements are components.
The category of VOC (Volatile Organic Chemical) includes a number of chemicals that are both man-made and naturally occurring. Water from wells and utilities may contain some of these contaminants. Some VOCs are pesticides, herbicides, or insecticides that seep into the ground water after application. Other VOCs enter the water supply through industrial or other waste disposal. This category also includes total trihalomethanes, which are a by-product of chlorination.
A VOC reduction claim by the manufacturer means the system reduces the concentration of all of the following contaminants:
alachlor endrin simazine atrazine ethylbenzene styrene benzene ethylene dibromide (EDB) 1,1,2,2-tetrachloroethane carbofuran haloacetonitriles tetrachloroethylene carbon tetrachloride bromochloroacetonitrile toluene chlorobenzene dibromoacetonitrile 2,4,5-TP(silvex) chloropicrin dichloroacetonitrile tribromoacetic acid 2,4-D trichloroacetonitrile 1,2,4-trichlorobenzene dibromochloropropane (DBCP) haloketones 1,1,1-trichloroethane o-dichlorobenzene 1,1-dichloro-2-propanone 1,1,2-trichloroethane p-dichlorobenzene 1,1,1-trichloro-2-propanone trichloroethylene 1,2-dichloroethane heptachlor trihalomethanes (TTHM) 1,1-dichloroethylene heptachlor epoxide bromodichloromethane cis-1,2-dichloroethylene hexachlorobutadiene bromoform trans-1,2-dichloroethylene hexachlorocyclopentadiene chlorodibromomethane 1,2-dichloropropane lindane chloroform cis-1,3-dichloropropylene methoxychlor xylenes dinoseb pentachlorophenol
Number of matching Manufacturers is 1
Number of matching Products is 4