These NSF Official Listings are current as of Friday, April 05, 2013 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://www.nsf.org/Certified/Plumbing/Listings.asp?Company=01540&Standard=014&LowLead=Y&
NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| Hershey Valve Company, Ltd. | ![]() |
| No. 16 Jing 2nd Road | |
| Wuchi Town, Taichung 435 | |
| Taiwan | |
| 886 42 639 2777 | |
| Visit this company's website |
Facility : Jiangsu, China
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Pipe+++ [G] |
CPVC 4120 |
Hershey Pipe |
ASTM F441 |
| 1/2" - 4" Sch 40 | |||
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Valves (PW)+ @ [G] |
PVC I-G1 |
VP |
ASTM F1970 |
|
Compact Ball Valves - Solvent Weld |
|||
| VP-910 1/2" - 2" | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
@ PVC Valves rated as 150 psi at 73°F.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Valves (PW)+ @ [G] |
PVC I-G1 |
VP |
ASTM F1970 |
|
Compact Ball Valves - Threaded |
|||
| VP-910 1/2" - 2" | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
@ PVC Valves rated as 150 psi at 73°F.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Facility : Taichung, Taiwan
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Pipe+++ [G] |
CPVC 4120 |
Hershey Pipe |
ASTM F441 |
| 1/2" - 4" Sch 80 | |||
| 1/2" - 4" Sch 40 | |||
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Pipe+++ [G] |
CPVC 4120 |
Hershey Pipe |
ASTM F442 |
| 1/2" - 4" SDR 11 | |||
| 1/2" - 4" SDR 13.5 | |||
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Pipe+++ [G] |
CPVC 4120 |
Hershey Pipe |
ASTM D2846 |
| 1/2" - 2" SDR 11 | |||
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Valves (PW)+ @ [G] |
PVC I-G1 |
VP |
ASTM F1970 |
|
Compact Ball Valves - Solvent Weld |
|||
| VP-900 1/2" - 2" | VP-910 1/2" - 2" | ||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
@ PVC Valves rated at 150psi at 73°F.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Valves (PW)+ @ [G] |
PVC I-G1 |
VP |
ASTM F1970 |
|
Compact Ball Valves - Threaded |
|||
| VP-900 1/2" - 2" | VP-910 1/2" - 2" | ||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
@ PVC Valves rated at 150psi at 73°F.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Number of matching Manufacturers is 1
Number of matching Products is 12
Processing time was 0 seconds