NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| Georg Fischer Sloane, LLC | |
| 7777 Sloane Drive | |
| Little Rock, AR 72206 | |
| United States | |
| 800-423-2686 | |
| 501-490-7247 | |
| Visit this company's website |
Facility : Little Rock, AR
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Fittings+ *** [G] |
PVC I-G1 |
+GF+ or GSR |
ASTM D2464 |
|
45° Ell, T x T |
|||
| 819-xxx | 1/4" - 4" | ||
|
90° Ell, S x T |
|||
| 807-xxx | 1/2" - 3" | ||
|
90° Ell, T x T |
|||
| 808-xxx | 1/4" - 4" | ||
|
Cap, T |
|||
| 848-xxx | 1/4" - 4" | ||
|
Coupling, T x T |
|||
| 830-xxx | 1/4" - 4" | ||
|
Female Adapter, S x T |
|||
| 835-xxx | 1/4" - 4" | ||
|
Male Adapter, S x MT |
|||
| 836-xxx | 1/2" - 4" | ||
|
Nipple, MT x MT |
|||
| 861-xxx | 1/2" - 3" | ||
|
Plug, MT |
|||
| 850-xxx | 1/4" - 4" | ||
|
Reducer Bushing, MT x T |
|||
| 839-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" |
| 3/4" x 1/4" | 3/4" x 3/8" | 3/4" x 1/2" | 1" x 1/4" |
| 1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" |
| 1 1/4" x 1" | 1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" |
| 2" x 1/2" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" |
| 2" x 1 1/2" | 3" x 2" | 4" x 2" | 4" x 3" |
|
Reducer Bushing, Spg x T |
|||
| 838-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" |
| 3/4" x 1/4" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" |
| 1 1/4" x 1/2" | 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/4" x 1/2" |
| 1 1/4" x 1 1/4" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" |
| 1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" | 2" x 1" |
| 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | 2 1/2" x 2" |
| 3" x 2" | 3" x 2 1/2" | 4" x 2" | 4" x 3" |
|
Reducer Coupling, T x T |
|||
| 830-xxx | 3/8" x 1/4" | 3/4" x 1/2" | 1/2" x 3/8" |
| 1/2" x 3/4" | 1/2" x 1/4" | 1" x 1/2" | 1" x 3/4" |
| 1 1/4" x 3/4" | 1 1/2" x 1" | 2" x 1 1/2" | |
|
Tees, S x S x T |
|||
| 802-xxx | 1/2" - 2" | ||
|
Tees, T x T x T |
|||
| 805-xxx | 1/4" - 4" | ||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
*** -xxx Suffix designates nominal size
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Fittings+ *** [G] |
PVC I-G1 |
+GF+ or GSR |
ASTM D2466 |
|
45° Ell, S x S |
|||
| 417-xxx | 1/2" - 8" | ||
|
90° Ell, S x FT |
|||
| 407-xxx | 1/2" - 2" | ||
|
90° Ell, S x S |
|||
| 406-xxx | 1/2" - 8" | ||
|
90° Ell, S x T |
|||
| 407-xxx | 1/2" x 3/4" | 1" x 3/4" | 3/4" x 1/2" |
| 1 1/4" x 1" | 1" x 1/2" | 1 1/2" x 1" | |
|
90° Ell, T x T |
|||
| 408-xxx | 1/2" - 1 1/4" | ||
|
90° Reducing Ell, S x S |
|||
| 406-xxx | 3/4" x 1/2" | 1 1/4" x 1" | 1" x 1/2" |
| 1 1/2" x 1" | 1" x 3/4" | ||
|
90° Street Ell, MT x FT |
|||
| 412-xxx | 1/2" - 2" | ||
|
90° Street Ell, Mt x S |
|||
| 410-xxx | 1/2" - 2" | ||
|
90° Street Ell, Spg x S |
|||
| 409-xxx | 1/2" - 2" | ||
|
Cap, S |
|||
| 447-xxx | 1/2" - 12" | ||
|
Cap, T |
|||
| 448-xxx | 1/2" - 6" | ||
|
Coupling, S x S |
|||
| 429-xxx | 1/2" - 12" | 3/4" x 1/2" | 1" x 3/4" |
|
Coupling, T x T |
|||
| 430-xxx | 1/2" - 1" | ||
|
Crosses, S x S x S x S |
|||
| 420-xxx | 1/2" - 2" | 2 1/2" x 2 1/2" x 2 1/2" x 1 1/2" | 3" x 3" x 1 1/2" x 1 1/2" |
| 4" x 4" x 1" x 1" | 4" x 4" x 2" x 2" | 3" x 3" x 1" x 1" | 3" x 3" x 2" x 2" |
| 4" x 4" x 1 1/2" x 1 1/2" | |||
|
Female Adapter, S x T |
|||
| 435-xxx | 1/2" - 8" | 3/4" x 1/2" | 3/4" x 1" |
| 1" x 3/4" | |||
|
Male Adapter, MT x S |
|||
| 436-xxx | 1/2" - 6" | 1/2" x 3/4" | 3/4" x 1/2" |
| 3/4" x 1" | 1" x 3/4" | 1" x 1 1/4" | 1 1/4" x 1" |
| 1 1/4" x 1 1/2" | 1 1/2" x 1 1/4" | 1 1/2" x 2" | 2" x 1 1/2" |
| 3" x 4" | |||
|
Plug, MT |
|||
| 450-xxx | 1/2" - 4" | ||
|
Plug, S |
|||
| 449-xxx | 1/2" - 4" | ||
|
Reducer Bushing, MT x T |
|||
| 439-xxx | 1/2" x 3/8" | 3/4" x 1/2" | 1" x 3/4" |
| 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" |
| 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1" | 2" x 1 1/2" |
|
Reducer Bushing, Spg x S |
|||
| 437-xxx | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" |
| 1 1/4" x 1/2" | 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" |
| 1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 1 1/2" x 1" |
| 2" x 1/2" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" |
| 2" x 1 1/2" | 2 1/2" x 3/4" | 2 1/2" x 1" | 2 1/2" x 1 1/4" |
| 2 1/2" x 1 1/2" | 2 1/2" x 2" | 3" x 1" | 3" x 1 1/4" |
| 3" x 1 1/2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" |
| 4" x 2 1/2" | 4" x 3" | 5" x 4" | 6" x 3" |
| 6" x 4" | 6" x 5" | 8" x 2" | 8" x 4" |
| 8" x 6" | 10" x 8" | ||
|
Reducer Bushing, Spg x T |
|||
| 438-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/4" |
| 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" |
| 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/4" x 1 1/2" | 1 1/2" x 1/2" |
| 1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1/2" |
| 2" x 3/4" | 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" |
| 2 1/2" x 1 1/2" | 2 1/2" x 2" | 3" x 3/4" | 3" x 1" |
| 3" x 2" | 3" x 2 1/2" | 4" x 1" | 4" x 2" |
| 4" x 2 1/2" | 4" x 3" | 6" x 4" | |
|
Reducing Tee, S x S x S |
|||
| 401-xxx | 1/2" x 1/2" x 3/4" | 1/2" x 1/2" x 1" | 3/4" x 1/2" x 1/2" |
| 3/4" x 1/2" x 3/4" | 3/4" x 3/4" x 1/2" | 3/4" x 3/4" x 1" | 1" x 1/2" x 1" |
| 1" x 3/4" x 1/2" | 1" x 3/4" x 3/4" | 1" x 1" x 1/2" | 1" x 1" x 3/4" |
| 1" x 1" x 1 1/4" | 1" x 1" x 1 1/2" | 1 1/4" x 1" x 1/2" | 1 1/4" x 1" x 1" |
| 1 1/4" x 1 1/4" x 1/2" | 1 1/4" x 1 1/4" x 3/4" | 1 1/4" x 1 1/4" x 1" | 1 1/4" x 1 1/4" x 1 1/2" |
| 1 1/4" x 1 1/4" x 2" | 1 1/2" x 1 1/4" x 1/2" | 1 1/2" x 1 1/4" x 1/2" | 1 1/2" x 1 1/4" x 3/4" |
| 1 1/2" x 1 1/4" x 1" | 1 1/2" x 1 1/2" x 1/2" | 1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" |
| 1 1/2" x 1 1/2" x 1 1/4" | 1 1/2" x 1 1/2" x 2" | 2" x 1/2" x 3/4" | 2" x 1 1/2" x 1" |
| 2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" | 2" x 2" x 1 1/4" |
| 2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 1/2" | 2 1/2" x 2 1/2" x 3/4" | 2 1/2" x 2 1/2" x 1" |
| 3" x 3" x 1/2" | 3" x 3" x 3/4" | 3" x 3" x 1" | 3" x 3" x 1 1/4" |
| 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 1/2" | 4" x 4" x 3/4" |
| 4" x 4" x 1" | 4" x 4" x 1 1/4" | 4" x 4" x 1 1/2" | 4" x 4" x 2" |
| 4" x 4" x 3" | 6" x 6" x 2" | 6" x 6" x 3" | 6" x 6" x 4" |
| 8" x 8" x 3" | 8" x 8" x 4" | ||
|
Reducing Tee, S x S x T |
|||
| 402-xxx | 1/2" x 1/2" x 3/4" | 3/4" x 1/2" x 1/2" | 3/4" x 1/2" x 3/4" |
| 3/4" x 3/4" x 1/2" | 1" x 3/4" x 1/2" | 1" x 1" x 1/2" | 1" x 1" x 3/4" |
| 1 1/4" x 1" x 1/2" | 1 1/4" x 1" x 1" | 1 1/4" x 1 1/4" x 1/2" | 1 1/4" x 1 1/4" x 3/4" |
| 1 1/4" x 1 1/4" x 1" | 1 1/2" x 1 1/4" x 1/2" | 1 1/2" x 1 1/4" x 3/4" | 1 1/2" x 1 1/4" x 1" |
| 1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" | 1 1/2" x 1 1/2" x 1/2" | 1 1/2" x 1 1/2" x 3/4" |
| 1 1/2" x 1 1/2" x 1" | 1 1/2" x 1 1/2" x 1 1/4" | 2" x 1 1/2" x 3/4" | 2" x 1 1/2" x 1" |
| 2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" | 2" x 2" x 1 1/4" |
| 2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 3/4" | 2 1/2" x 2 1/2" x 1" | 4" x 4" x 3" |
| 6" x 6" x 3" | |||
|
Tee, S x S x S |
|||
| 401-xxx | 1/2" - 8" | ||
|
Tee, S x S x T |
|||
| 402-xxx | 1/2" - 2" | ||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
*** -xxx Suffix designates nominal size
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Fittings+ @ *** [G] |
PVC I-G1 |
+GF+ or GSR |
ASTM D2467 |
|
45° Ell, S x S |
|||
| 817-xxx | 1/4" - 8" | ||
|
90° Ell, S x S |
|||
| 806-xxx | 1/4" - 8" | ||
|
Cap, S |
|||
| 847-xxx | 1/4" - 12" | ||
|
Coupling, S x S |
|||
| 829-xxx | 1/4" - 12" | ||
|
Reducer Bushing, Spg x S |
|||
| 837-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" |
| 1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" |
| 1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" |
| 1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" | 2" x 1" |
| 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | 2 1/2" x 2" |
| 3" x 1 1/2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" |
| 4" x 3" | 6" x 3" | 6" x 4" | 8" x 6" |
| 10" x 6" | 10" x 8" | 12" x 8" | 12" x 10" |
|
Reducer Coupling, S x S |
|||
| 829-xxx | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" |
| 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 3/4" | 1 1/2" x 1" |
| 1 1/2" x 1 1/4" | 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" |
| 2 1/2" x 1 1/2" | 3" x 2" | 4" x 3" | 6" x 4" |
| 8" x 6" | |||
|
Reducing Tee, S x S x S |
|||
| 801-xxx | 3/4" x 3/4" x 1/2" | 1" x 1" x 1/2" | 1" x 1" x 3/4" |
| 1 1/4" x 1 1/4" x 1" | 1 1/2" x 1 1/2" x 1/2" | 1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" |
| 1 1/2" x 1 1/2" x 1 1/4" | 2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" |
| 2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" |
| 4" x 4" x 2" | 4" x 4" x 3" | 6" x 6" x 4" | 8" x 8" x 6" |
|
Tee, S x S x S |
|||
| 801-xxx | 1/4" - 8" | ||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
@ Fittings or systems to be installed in accordance with the manufacturer's instructions,
ASTM Standard and latest edition of Uniform Plumbing Code.
*** -xxx Suffix designates nominal size
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Fittings+ @ *** [G] |
PVC I-G1 |
+GF+ or GSR |
ASTM D2467 |
|
45° Ell, T x T |
|||
| 819-xxx | 1/4" - 4" | ||
|
90° Ell, S x T |
|||
| 807-xxx | 1/2" - 3" | ||
|
90° Ell, T x T |
|||
| 808-xxx | 1/4" - 4" | ||
|
Cap, T |
|||
| 848-xxx | 1/4" - 4 | ||
|
Coupling, T x T |
|||
| 830-xxx | 1/4" - 4" | ||
|
Female Adapter, S x T |
|||
| 835-xxx | 1/4" - 4" | ||
|
Male Adapter, S x T |
|||
| 836-xxx | 1/2" - 4" | ||
|
Nipple, MT x MT |
|||
| 861-xxx | 1/2" x 3" | ||
|
Plug, MT |
|||
| 850-xxx | 1/4" - 4" | ||
|
Reducer Bushing, MT x T |
|||
| 839-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" |
| 3/4" x 1/4" | 3/4" x 3/8" | 3/4" x 1/2" | 1" x 1/4" |
| 1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" |
| 1 1/4" x 1" | 1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" |
| 2" x 1/2" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" |
| 2 1/2" x 2" | 3" x 2" | 4" x 2" | 4" x 3" |
|
Reducer Bushing, Spg x T |
|||
| 838-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" |
| 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" |
| 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" |
| 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" |
| 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" |
| 2 1/2" x 2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" |
|
Reducer Coupling, T x T |
|||
| 830-xxx | 3/8" x 1/4" | 3/4" x 1/2" | 1 1/4" x 3/4" |
| 1/2" x 1/4" | 1" x 1/2" | 1 1/2" x 1" | 1/2" x 3/4" |
| 1" x 3/4" | 2" x 1 1/2" | ||
|
Tees, S x S x T |
|||
| 802-xxx | 1/2" - 2" | ||
|
Tees, T x T x T |
|||
| 805-xxx | 1/4" - 4" | ||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
@ Fittings or systems to be installed in accordance with the manufacturer's instructions,
ASTM Standard and latest edition of Uniform Plumbing Code.
*** -xxx Suffix designates nominal size
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Fittings@ *** +++ [G] |
CPVC 41 |
+GF+ or GSR |
ASTM F439 |
|
45° Ell, S x S |
|||
| 9817-xxx | 1/4" - 8" | ||
|
90° Ell, S x S |
|||
| 9806-xxx | 1/4" - 8" | ||
|
Cap, S |
|||
| 9847-xxx | 3/8" - 12" | ||
|
Coupling, S x S |
|||
| 9829-xxx | 1/4" - 12" | ||
|
Reducer Bushing, Spg x S |
|||
| 9837-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" |
| 1" x 1/2" | 1" x 3/4" | 1 1/4" x 1/2" | 1 1/4" x 3/4" |
| 1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" |
| 1 1/2" x 1 1/4" | 2" x 1/2" | 2" x 3/4" | 2" x 1" |
| 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" | 2 1/2" x 2" |
| 3" x 1 1/2" | 3" x 2" | 3" x 2 1/2" | 4" x 2" |
| 4" x 3" | 6" x 4" | 8" x 6" | 10" x 6" |
| 10" x 8" | 12" x 10" | ||
|
Reducer Coupling, S x S |
|||
| 9829-xxx | 1/2" x 3/8" | 3/4" x 1/2" | 1" x 1/2" |
| 1" x 3/4" | 1 1/4" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" |
| 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/2" |
| 3" x 2" | 4" x 3" | 6" x 4" | 8" x 6" |
|
Reducing Tee, S x S x S |
|||
| 9801-xxx | 3/4" x 3/4" x 1/2" | 1" x 1" x 1/2" | 1" x 1" x 3/4" |
| 1 1/4" x 1 1/4" x 1" | 1 1/2" x 1 1/2" x 3/4" | 1 1/2" x 1 1/2" x 1" | 1 1/2" x 1 1/2" x 1 1/4" |
| 1 1/2" x 1 1/2" x 1 1/2" | 2" x 2" x 1/2" | 2" x 2" x 3/4" | 2" x 2" x 1" |
| 2" x 2" x 1 1/2" | 2 1/2" x 2 1/2" x 2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" |
| 4" x 4" x 2" | 4" x 4" x 3" | 6" x 4" | 8" x 8" x 6" |
|
Tee, S x S x S |
|||
| 9801-xxx | 1/4" - 8" | ||
@ Fittings or systems to be installed in accordance with the manufacturer's instructions,
ASTM Standard and latest edition of Uniform Plumbing Code.
*** -xxx Suffix designates nominal size
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Fittings*** +++ [G] |
CPVC 41 |
+GF+ or GSR |
ASTM F437 |
|
45° Ell, T x T |
|||
| 9819-xxx | 1/4" - 4" | ||
|
90° Ell, T x T |
|||
| 9808-xxx | 1/4" - 4" | ||
|
Cap, T |
|||
| 9848-xxx | 1/4" - 4" | ||
|
Coupling, T x T |
|||
| 9830-xxx | 1/4" - 4" | ||
|
Female Adapter, S x T |
|||
| 9835-xxx | 1/4" - 4" | ||
|
Male Adapter, S x MT |
|||
| 9836-xxx | 1/2" - 4" | ||
|
Nipple, MT x MT |
|||
| 9861-xxx | 1/4" - 2" | ||
|
Plug, MT |
|||
| 9850-xxx | 1/4" - 4" | ||
|
Reducer Bushing, MT x T |
|||
| 9839-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" |
| 3/4" x 3/8" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" |
| 1 1/4" x 1" | 1 1/2" x 1/2" | 1 1/2" x 3/4" | 1 1/2" x 1" |
| 1 1/2" x 1 1/4" | 2" x 3/4" | 2" x 1" | 2" x 1 1/4" |
| 2" x 1 1/2" | 3" x 2" | 4" x 3" | |
|
Reducer Bushing, Spg x T |
|||
| 9838-xxx | 3/8" x 1/4" | 1/2" x 1/4" | 1/2" x 3/8" |
| 3/4" x 1/4" | 3/4" x 1/2" | 1" x 1/2" | 1" x 3/4" |
| 1 1/4" x 1/2" | 1 1/4" x 3/4" | 1 1/4" x 1" | 1 1/2" x 1/2" |
| 1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1/2" |
| 2" x 3/4" | 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" |
| 2 1/2" x 1 1/2" | 2 1/2" x 2" | 3" x 2" | 4" x 2" |
| 4" x 3" | |||
|
Reducer Coupling, T x T |
|||
| 9830-xxx | 1/2" x 1/4" | 1/2" x 3/8" | 3/4" x 1/2" |
| 1" x 1/2" | 1" x 3/4" | 1 1/2" x 1" | |
|
Tee, T x T x T |
|||
| 9805-xxx | 1/4" - 4" | ||
*** -xxx Suffix designates nominal size
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Pipe+ @ ^ § [G] |
PVC 1120 |
+GF+ or GSR |
ASTM D1785 |
| >= 1/2" Sch 80 | |||
| >= 1/2" Sch 40 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
@ Fittings or systems to be installed in accordance with the manufacturer's instructions,
ASTM Standard and latest edition of Uniform Plumbing Code.
^ Sockets and gasketed bell ends are not tested or Listed by NSF for this production
facility.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Pipe@ ˘ § +++ [G] |
CPVC 4120 |
+GF+ or GSR |
ASTM F441 |
| 1/2" - 2", 2 1/2", 3", 4", 6", 8", 10", 12" Sch 40 | |||
| 1/2" - 2", 2 1/2", 3", 4", 6", 8", 10", 12" Sch 80 | |||
@ Fittings or systems to be installed in accordance with the manufacturer's instructions,
ASTM Standard and latest edition of Uniform Plumbing Code.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Pipe˘ +++ [G] |
CPVC 4120 |
+GF+ or GSR |
CSA B137.6 |
| 1 1/4" - 2 1/2" Sch 80 | |||
| 1 1/4" - 2 1/2" Sch 40 | |||
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Fittings# + [G] |
PVC I-G1 |
+GF+ |
ASTM F1970 |
|
Flange - Van Stone (S) Sch 80 |
|||
| 3" 854-030 | 4" 854-040 | 6" 854-060 | 8" 854-080 |
| 10" 854-100 | 12" 854-120 | ||
# Product tested for use in 73°F with a rated pressure of 150 psi.
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Fittings# +++ [G] |
CPVC |
+GF+ |
ASTM F1970 |
|
Flange - Van Stone (S) Sch 80 |
|||
| 1/2" 9854-005 | 3/4" 9854-007 | 1" 9854-010 | 1 1/4" 9854-012 |
| 1 1/2" 9854-015 | 2" 9854-020 | 2 1/2" 9854-025 | 3" 9854-030 |
| 4" 9854-040 | 6" 9854-060 | 8" 9854-080 | 10" 9854-100 |
| 12" 9854-120 | |||
# Product tested for use in 73°F with a rated pressure of 150 psi.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||