These NSF Official Listings are current as of Sunday, February 03, 2013 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://www.nsf.org/Certified/Plumbing/Listings.asp?Company=38790&Standard=014&LowLead=Y&
NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| REHAU Construction LLC | ![]() |
| 1501 Edwards Ferry Road, N.E. | |
| Leesburg, VA 20176 | |
| United States | |
| 800-247-9445 | |
| 703-777-5255 | |
| Visit this company's website |
Facility : # 1 Germany
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Pipe* ^ +++ [G] |
PEX 3306 |
MUNICIPEX |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ +++ [G] |
PEX 3306 |
MUNICIPEX |
AWWA C904 |
| 1/2" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
MUNICIPEX |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ +++ [G] |
PEX 3306 |
MUNICIPEX Protect |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ +++ [G] |
PEX 3306 |
MUNICIPEX Protect |
AWWA C904 |
| 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
MUNICIPEX Protect |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe$ * ^ § +++ [G] |
PEX 3006 |
RAUPEX® |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe$ * ^ § +++ [G] |
PEX 3006 |
RAUPEX® |
AWWA C904 |
| 1/2" - 2" SDR 9 | |||
$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe$ * ^ ˘ § +++ [G] |
PEX |
RAUPEX® |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ § +++ [G] |
PEX 3306 |
RAUPEX® Blue UV-Shield |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
RAUPEX® Blue UV-Shield |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ § +++ [G] |
PEX 3306 |
RAUPEX Red UV-Shield |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
RAUPEX Red UV-Shield |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ § +++ [G] |
PEX 3306 |
RAUPEX White UV-Shield |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
RAUPEX White UV-Shield |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX 3006 |
Raupex® Raugeo Grey UV Shield |
ASTM F876/F877 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
Raupex® Raugeo Grey UV Shield |
CSA B137.5 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX 3006 |
Raupex® Raugeo |
ASTM F876/F877 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
Raupex® Raugeo |
CSA B137.5 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction,
including manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Facility : # 7 USA
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Pipe* ^ § +++ [G] |
PEX 3306 |
MUNICIPEX |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ § +++ [G] |
PEX 3306 |
MUNICIPEX |
AWWA C904 |
| 1/2" - 1 1/4" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
MUNICIPEX |
CSA B137.5 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ +++ [G] |
PEX 3306 |
MUNICIPEX Protect |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ +++ [G] |
PEX 3306 |
MUNICIPEX Protect |
AWWA C904 |
| 1/2" - 1 1/4" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
MUNICIPEX Protect |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe$ * ^ § +++ [G] |
PEX 3006 |
RAUPEX® |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe$ * ^ § +++ [G] |
PEX 3006 |
RAUPEX® |
AWWA C904 |
| 1/2" - 1 1/4" SDR 9 | |||
$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe$ * ^ ˘ § +++ [G] |
PEX |
RAUPEX® |
CSA B137.5 |
| 3/8" - 2" | |||
$ Non-barrier pipe.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ § +++ [G] |
PEX 3306 |
RAUPEX® Blue UV-Shield |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
RAUPEX® Blue UV-Shield |
CSA B137.5 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX 3006 |
Raupex Raugeo |
ASTM F876/F877 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
Raupex Raugeo |
CSA B137.5 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX 3306 |
Raupex Raugeo Grey UV-Shield |
ASTM F876/F877 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
Raupex Raugeo Grey UV-Shield |
CSA B137.5 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ § +++ [G] |
PEX 3306 |
RAUPEX® Red UV-Shield |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
RAUPEX® Red UV-Shield |
CSA B137.5 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ § +++ [G] |
PEX 3306 |
RAUPEX® White UV-Shield |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe* ^ ˘ § +++ [G] |
PEX |
RAUPEX® White UV-Shield |
CSA B137.5 |
| 3/8" - 2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Facility : # 11 Switzerland
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Pipe# * ^ § +++ [G] |
PEX 3306 |
Municipex PI |
ASTM F876/F877 |
| 1" - 2" SDR 9 | |||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe# * ^ § +++ [G] |
PEX 3306 |
Municipex PI |
AWWA C904 |
| 1" - 2" SDR 9 | |||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe# * ^ ˘ § +++ [G] |
PEX |
Municipex PI |
CSA B137.5 |
| 1" - 2" SDR 9 | |||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe# * ^ ˘ § +++ [G] |
PEX |
Insulpex Blue UV Shield |
CSA B137.5 |
| 1" - 2" SDR 9 | |||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe# * ^ § +++ [G] |
PEX 3306 |
Insulpex Blue UV Shield |
ASTM F876/F877 |
| 1" - 2" SDR 9 | |||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe# * ^ § +++ [G] |
PEX 3306 |
Insulpex Red UV Shield |
ASTM F876/F877 |
| 1" - 2" SDR 9 | |||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe# * ^ ˘ § +++ [G] |
PEX |
Insulpex Red UV Shield |
CSA B137.5 |
| 1" - 2" SDR 9 | |||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe# * ^ § +++ [G] |
PEX 3306 |
Insulpex White UV Shield |
ASTM F876/F877 |
| 1" - 2" SDR 9 | |||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Pipe# * ^ ˘ § +++ [G] |
PEX |
Insulpex White UV Shield |
CSA B137.5 |
| 1" - 2" SDR 9 | |||
# Insulated material has not been evaluated to Standard 14 Requirements, only Standard 61.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Number of matching Manufacturers is 1
Number of matching Products is 47
Processing time was 0 seconds