These NSF Official Listings are current as of Sunday, September 05, 2010 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://www.nsf.org/Certified/Plumbing/Listings.asp?Company=42850&Standard=014&
NSF/ANSI STANDARD 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| Spears Manufacturing Company | ![]() |
| 15853 Olden Street | |
| P.O. Box 9203 | |
| Sylmar, CA 91342 | |
| United States | |
| 818-364-1611 | |
| Visit this company's website |
Facility : # 1 Caney, KS
Corrosive Waste - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Fittings§ [1] [3] [4] |
CPVC |
Spears LabWaste™ |
ASTM F2618 |
|
1/16 Bend |
|||
| P324-xxxC | |||
|
1/16 Bend, Street |
|||
| P326-xxxC | |||
|
1/4 Bend |
|||
| P300-xxxC | |||
|
1/4 Bend, Long Sweep |
|||
| P304-xxxC | |||
|
1/4 Bend, Street |
|||
| P302-xxxC | |||
|
1/4 Bend, Street Long Sweep |
|||
| P309-xxxC | |||
|
1/6 Bend |
|||
| P319-xxxC | |||
|
1/6 Bend, Street |
|||
| P320-xxxC | |||
|
1/8 Bend |
|||
| P321-xxxC | |||
|
1/8 Bend, Street |
|||
| P323-xxxC | |||
|
45° Wye |
|||
| P600-xxxC | |||
|
45° Wye, Reducing |
|||
| P601-xxxC | |||
|
Cap |
|||
| P116-xxxC | |||
|
Cleanout Adapter |
|||
| P105-xxxC | |||
|
Cleanout Adapter w/ Plug |
|||
| P105X-xxxC | |||
|
Cleanout Plug |
|||
| P106-xxxC | |||
|
Cleanout Tee w/ Plug |
|||
| P444X-xxxC | |||
|
Combination Wye & 1/8 Bend |
|||
| P501-xxxC | |||
|
Combination Wye & 1/8 Bend (2-piece) |
|||
| P503-xxxC | |||
|
Combination Wye & 1/8 Bend, Reducing |
|||
| P502-xxxC | |||
|
Combination Wye & 1/8 Bend, Reducing (2-piece) |
|||
| P504-xxxC | |||
|
Countersunk Plug |
|||
| P110-xxxC | |||
|
Coupling |
|||
| P100-xxxC | |||
|
Double 1/4 Bend |
|||
| P327-xxxC | |||
|
Double Combination Wye & 1/8 Bend |
|||
| P507-xxxC | |||
|
Double Sanitary Tee |
|||
| P428-xxxC | |||
|
Double Sanitary Tee, Reducing |
|||
| P429-xxxC | |||
|
Double Wye |
|||
| P611-xxxC | |||
|
Double Wye, Reducing |
|||
| P612-xxxC | |||
|
Drum Trap |
|||
| P720-xxxC | |||
|
Duriron Transition Fittings |
|||
| P095-xxxC | P097-xxxC | ||
|
Female Adapter |
|||
| P101-xxxC | |||
|
Flange |
|||
| P854-xxxC | |||
|
Flush Bushing |
|||
| P107-xxxC | |||
|
Flush Cleanout Tee |
|||
| P445-xxxC | |||
|
Flush Cleanout Tee w/ Plug |
|||
| P445X-xxxC | |||
|
Glass Transition Fittings |
|||
| P098-xxxC | |||
|
Grooved Couplings |
|||
| P096-xxxC | |||
|
Hub Adapter |
|||
| P123-xxxC | |||
|
Increaser Reducer |
|||
| P102-xxxC | |||
|
L.A. Pattern P-Trap w/ Union Nut |
|||
| P711P-xxxC | |||
|
Male Adapter |
|||
| P109-xxxC | |||
|
No-Hub Adapter |
|||
| P119-xxxC | |||
|
P-Trap |
|||
| P706X-xxxC | |||
|
P-Trap w/ Union Nut |
|||
| P-708P-xxxC | |||
|
Reducing Sanitary Tee, Street |
|||
| P404-xxxC | |||
|
Repair Coupling |
|||
| P130-xxxC | |||
|
Return Bend |
|||
| P700-xxxC | |||
|
Running Trap |
|||
| P705R-xxxC | |||
|
Sanitary Tee |
|||
| P400-xxxC | |||
|
Sanitary Tee, Reducing |
|||
| P401-xxxC | |||
|
Tailpiece Adapter w/ Nut |
|||
| P704P-xxxC | |||
|
Transition Coupling |
|||
| P099-xxxC | |||
|
Trap Adapter - Female w/ Chrome Nut & Washer |
|||
| P104X-xxxC | |||
|
Trap Adapter - Female w/ Plastic Nut & Washer |
|||
| P104R-xxxC | |||
|
Trap Adapter w/ Nut |
|||
| P103P-xxxC | |||
|
Vent Ell |
|||
| P331-xxxC | |||
|
Vent Ell, Street |
|||
| P333-xxxC | |||
|
Vent Tee |
|||
| P441-xxxC | |||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[1] Chemical resistance evaluation includes change of apparent tensile strength evaluation
within ±10% and change in weight of ±2% after chemical exposure for 7 days.
[3] xxx = different size code designation
[4] Spears LabWaste™ CPVC Corrosive Waste Drainage System consists of Spears LabWaste™ CPVC
Pipe, Spears LabWaste™ CPVC Fittings, and Low VOC Yellow One-Step LW-5 CPVC Solvent
Cement.
|
|||
Fittings[1] [3] [4] |
CPVC |
Spears LabWaste™ |
ASTM F2618 |
|
1/4 Bend w/ Side Inlet |
|||
| P300s-xxxC | |||
|
Double Fixture Fitting |
|||
| P500-xxxC | |||
|
Drum Trap |
|||
| P720-xxxC | |||
|
Jar Trap |
|||
| P712-xxxC | |||
|
Jar Trap w/ Tail Piece Adapter |
|||
| P712P-xxxC | |||
|
P-Trap w/ Cleanout |
|||
| P707X-xxxC | |||
|
S-Trap |
|||
| P705-xxxC | |||
[1] Chemical resistance evaluation includes change of apparent tensile strength evaluation
within ±10% and change in weight of ±2% after chemical exposure for 7 days.
[3] xxx = different size code designation
[4] Spears LabWaste™ CPVC Corrosive Waste Drainage System consists of Spears LabWaste™ CPVC
Pipe, Spears LabWaste™ CPVC Fittings, and Low VOC Yellow One-Step LW-5 CPVC Solvent
Cement.
|
|||
Pipe§ [1] [4] |
CPVC |
Spears LabWaste™ |
ASTM F2618 |
| 1 1/2" - 12" | |||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[1] Chemical resistance evaluation includes change of apparent tensile strength evaluation
within ±10% and change in weight of ±2% after chemical exposure for 7 days.
[4] Spears LabWaste™ CPVC Corrosive Waste Drainage System consists of Spears LabWaste™ CPVC
Pipe, Spears LabWaste™ CPVC Fittings, and Low VOC Yellow One-Step LW-5 CPVC Solvent
Cement.
|
|||
Pipe[1] [4] |
CPVC |
Spears LabWaste™ |
SE 1004[2] |
| 1 1/2" - 12" | |||
[1] Chemical resistance evaluation includes change of apparent tensile strength evaluation
within ±10% and change in weight of ±2% after chemical exposure for 7 days.
[2] Product tested for Dimensions, Mechanical Joint Testing, Flattening, Impact and Chemical
Resistance Testing.
[4] Spears LabWaste™ CPVC Corrosive Waste Drainage System consists of Spears LabWaste™ CPVC
Pipe, Spears LabWaste™ CPVC Fittings, and Low VOC Yellow One-Step LW-5 CPVC Solvent
Cement.
|
|||
Fittings[1] [3] [4] |
CPVC |
Spears LabWaste™ |
SE 1004[2] |
|
1/16 Bend |
|||
| P324-xxxC | |||
|
1/16 Bend, Street |
|||
| P326-xxxC | |||
|
1/4 Bend |
|||
| P300-xxxC | |||
|
1/4 Bend w/ Side Inlet |
|||
| P300s-xxxC | |||
|
1/4 Bend, Long Sweep |
|||
| P304-xxxC | |||
|
1/4 Bend, Street |
|||
| P302-xxxC | |||
|
1/4 Bend, Street Long Sweep |
|||
| P309-xxxC | |||
|
1/6 Bend |
|||
| P319-xxxC | |||
|
1/6 Bend, Street |
|||
| P320-xxxC | |||
|
1/8 Bend |
|||
| P321-xxxC | |||
|
1/8 Bend, Street |
|||
| P323-xxxC | |||
|
45° Wye |
|||
| P600-xxxC | |||
|
45° Wye, Reducing |
|||
| P601-xxxC | |||
|
Cap |
|||
| P116-xxxC | |||
|
Cleanout Adapter |
|||
| P105-xxxC | |||
|
Cleanout Adapter w/ Plug |
|||
| P105X-xxxC | |||
|
Cleanout Plug |
|||
| P106-xxxC | |||
|
Cleanout Tee w/ Plug |
|||
| P444X-xxxC | |||
|
Closet Flange |
|||
| P800-xxxC | |||
|
Combination Wye & 1/8 Bend |
|||
| P501-xxxC | |||
|
Combination Wye & 1/8 Bend (2-piece) |
|||
| P503-xxxC | |||
|
Combination Wye & 1/8 Bend, Reducing |
|||
| P502-xxxC | |||
|
Combination Wye & 1/8 Bend, Reducing (2-piece) |
|||
| P504-xxxC | |||
|
Countersunk Plug |
|||
| P110-xxxC | |||
|
Coupling |
|||
| P100-xxxC | |||
|
Double 1/4 Bend |
|||
| P327-xxxC | |||
|
Double Combination Wye & 1/8 Bend |
|||
| P507-xxxC | |||
|
Double Fixture Fitting |
|||
| P500-xxxC | |||
|
Double Sanitary Tee |
|||
| P428-xxxC | |||
|
Double Sanitary Tee, Reducing |
|||
| P429-xxxC | |||
|
Double Wye |
|||
| P611-xxxC | |||
|
Double Wye, Reducing |
|||
| P612-xxxC | |||
|
Duriron Transition Fittings |
|||
| P095-xxxC | P097-xxxC | ||
|
Female Adapter |
|||
| P101-xxxC | |||
|
Flange |
|||
| P854-xxxC | |||
|
Flush Bushing |
|||
| P107-xxxC | |||
|
Flush Cleanout Tee |
|||
| P445-xxxC | |||
|
Flush Cleanout Tee w/ Plug |
|||
| P445X-xxxC | |||
|
Grooved Couplings |
|||
| P096-xxxC | |||
|
Hub Adapter |
|||
| P123-xxxC | |||
|
Increaser Reducer |
|||
| P102-xxxC | |||
|
Jar Trap |
|||
| P712-xxxC | |||
|
Jar Trap w/ Tail Piece Adapter |
|||
| P712P-xxxC | |||
|
L.A. Pattern P-Trap w/ Union Nut |
|||
| P711P-xxxC | |||
|
Male Adapter |
|||
| P109-xxxC | |||
|
No-Hub Adapter |
|||
| P119-xxxC | |||
|
P-Trap |
|||
| P706X-xxxC | |||
|
P-Trap w/ Cleanout |
|||
| P707X-xxxC | |||
|
P-Trap w/ Union Nut |
|||
| P-708P-xxxC | |||
|
Reducing Sanitary Tee, Street |
|||
| P404-xxxC | |||
|
Repair Coupling |
|||
| P130-xxxC | |||
|
Return Bend |
|||
| P700-xxxC | |||
|
Running Trap |
|||
| P705R-xxxC | |||
|
S-Trap |
|||
| P705-xxxC | |||
|
Sanitary Tee |
|||
| P400-xxxC | |||
|
Sanitary Tee, Reducing |
|||
| P401-xxxC | |||
|
Tailpiece Adapter w/ Nut |
|||
| P704P-xxxC | |||
|
Transition Coupling |
|||
| P099-xxxC | |||
|
Trap Adapter - Female w/ Chrome Nut & Washer |
|||
| P104X-xxxC | |||
|
Trap Adapter - Female w/ Plastic Nut & Washer |
|||
| P104R-xxxC | |||
|
Trap Adapter w/ Nut |
|||
| P103P-xxxC | |||
|
Vent Ell |
|||
| P331-xxxC | |||
|
Vent Ell, Street |
|||
| P333-xxxC | |||
|
Vent Tee |
|||
| P441-xxxC | |||
[1] Chemical resistance evaluation includes change of apparent tensile strength evaluation
within ±10% and change in weight of ±2% after chemical exposure for 7 days.
[2] Product tested for Dimensions, Mechanical Joint Testing, Flattening, Impact and Chemical
Resistance Testing.
[3] xxx = different size code designation
[4] Spears LabWaste™ CPVC Corrosive Waste Drainage System consists of Spears LabWaste™ CPVC
Pipe, Spears LabWaste™ CPVC Fittings, and Low VOC Yellow One-Step LW-5 CPVC Solvent
Cement.
|
|||
Fittings[1] [3] [4] |
CPVC |
Spears LabWaste™ |
SE 1004[2] |
|
Drum Trap |
|||
| P720-xxxC | |||
|
Glass Transition Fittings |
|||
| P098-xxC | |||
[1] Chemical resistance evaluation includes change of apparent tensile strength evaluation
within ±10% and change in weight of ±2% after chemical exposure for 7 days.
[2] Product tested for Dimensions, Mechanical Joint Testing, Flattening, Impact and Chemical
Resistance Testing.
[3] xxx = different size code designation
[4] Spears LabWaste™ CPVC Corrosive Waste Drainage System consists of Spears LabWaste™ CPVC
Pipe, Spears LabWaste™ CPVC Fittings, and Low VOC Yellow One-Step LW-5 CPVC Solvent
Cement.
|
|||
Fittings[1] [3] [4] |
CPVC |
Spears LabWaste™ |
IGC 210 |
|
1/4 Bend w/ Side Inlet |
|||
| P300s-xxxC | |||
|
Double Fixture Fitting |
|||
| P500-xxxC | |||
|
Jar Trap |
|||
| P712-xxxC | |||
|
Jar Trap w/ Tail Piece Adapter |
|||
| P712P-xxxC | |||
|
P-Trap w/ Cleanout |
|||
| P707X-xxxC | |||
|
S-Trap |
|||
| P705-xxxC | |||
[1] Chemical resistance evaluation includes change of apparent tensile strength evaluation
within ±10% and change in weight of ±2% after chemical exposure for 7 days.
[3] xxx = different size code designation
[4] Spears LabWaste™ CPVC Corrosive Waste Drainage System consists of Spears LabWaste™ CPVC
Pipe, Spears LabWaste™ CPVC Fittings, and Low VOC Yellow One-Step LW-5 CPVC Solvent
Cement.
|
|||
Fittings§ [1] [3] [4] |
CPVC |
Spears LabWaste™ |
IGC 210 |
|
1/16 Bend |
|||
| P324-xxxC | |||
|
1/16 Bend, Street |
|||
| P326-xxxC | |||
|
1/4 Bend |
|||
| P300-xxxC | |||
|
1/4 Bend, Long Sweep |
|||
| P304-xxxC | |||
|
1/4 Bend, Street |
|||
| P302-xxxC | |||
|
1/4 Bend, Street Long Sweep |
|||
| P309-xxxC | |||
|
1/6 Bend |
|||
| P319-xxxC | |||
|
1/6 Bend, Street |
|||
| P320-xxxC | |||
|
1/8 Bend |
|||
| P321-xxxC | |||
|
1/8 Bend, Street |
|||
| P323-xxxC | |||
|
45° Wye |
|||
| P600-xxxC | |||
|
45° Wye, Reducing |
|||
| P601-xxxC | |||
|
Cap |
|||
| P116-xxxC | |||
|
Cleanout Adapter |
|||
| P105-xxxC | |||
|
Cleanout Adapter w/ Plug |
|||
| P105X-xxxC | |||
|
Cleanout Plug |
|||
| P106-xxxC | |||
|
Cleanout Tee w/ Plug |
|||
| P444X-xxxC | |||
|
Combination Wye & 1/8 Bend |
|||
| P501-xxxC | |||
|
Combination Wye & 1/8 Bend (2-piece) |
|||
| P503-xxxC | |||
|
Combination Wye & 1/8 Bend, Reducing |
|||
| P502-xxxC | |||
|
Combination Wye & 1/8 Bend, Reducing (2-piece) |
|||
| P504-xxxC | |||
|
Countersunk Plug |
|||
| P110-xxxC | |||
|
Coupling |
|||
| P100-xxxC | |||
|
Double 1/4 Bend |
|||
| P327-xxxC | |||
|
Double Combination Wye & 1/8 Bend |
|||
| P507-xxxC | |||
|
Double Sanitary Tee |
|||
| P428-xxxC | |||
|
Double Sanitary Tee, Reducing |
|||
| P429-xxxC | |||
|
Double Wye |
|||
| P611-xxxC | |||
|
Double Wye, Reducing |
|||
| P612-xxxC | |||
|
Drum Trap |
|||
| P720-xxxC | |||
|
Duriron Transition Fittings |
|||
| P095-xxxC | P097-xxxC | ||
|
Female Adapter |
|||
| P101-xxxC | |||
|
Flange |
|||
| P854-xxxC | |||
|
Flush Bushing |
|||
| P107-xxxC | |||
|
Flush Cleanout Tee |
|||
| P445-xxxC | |||
|
Flush Cleanout Tee w/ Plug |
|||
| P445X-xxxC | |||
|
Glass Transition Fittings |
|||
| P098-xxxC | |||
|
Grooved Couplings |
|||
| P096-xxxC | |||
|
Hub Adapter |
|||
| P123-xxxC | |||
|
Increaser Reducer |
|||
| P102-xxxC | |||
|
L.A. Pattern P-Trap w/ Union Nut |
|||
| P711P-xxxC | |||
|
Male Adapter |
|||
| P109-xxxC | |||
|
No-Hub Adapter |
|||
| P119-xxxC | |||
|
P-Trap |
|||
| P706X-xxxC | |||
|
P-Trap w/ Union Nut |
|||
| P-708P-xxxC | |||
|
Reducing Sanitary Tee, Street |
|||
| P404-xxxC | |||
|
Repair Coupling |
|||
| P130-xxxC | |||
|
Return Bend |
|||
| P700-xxxC | |||
|
Running Trap |
|||
| P705R-xxxC | |||
|
Sanitary Tee |
|||
| P400-xxxC | |||
|
Sanitary Tee, Reducing |
|||
| P401-xxxC | |||
|
Tailpiece Adapter w/ Nut |
|||
| P704P-xxxC | |||
|
Transition Coupling |
|||
| P099-xxxC | |||
|
Trap Adapter - Female w/ Chrome Nut & Washer |
|||
| P104X-xxxC | |||
|
Trap Adapter - Female w/ Plastic Nut & Washer |
|||
| P104R-xxxC | |||
|
Trap Adapter w/ Nut |
|||
| P103P-xxxC | |||
|
Vent Ell |
|||
| P331-xxxC | |||
|
Vent Ell, Street |
|||
| P333-xxxC | |||
|
Vent Tee |
|||
| P441-xxxC | |||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[1] Chemical resistance evaluation includes change of apparent tensile strength evaluation
within ±10% and change in weight of ±2% after chemical exposure for 7 days.
[3] xxx = different size code designation
[4] Spears LabWaste™ CPVC Corrosive Waste Drainage System consists of Spears LabWaste™ CPVC
Pipe, Spears LabWaste™ CPVC Fittings, and Low VOC Yellow One-Step LW-5 CPVC Solvent
Cement.
|
|||
Pipe§ [1] [4] |
CPVC |
Spears LabWaste™ |
IGC 210 |
| 1 1/2" - 12" | |||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[1] Chemical resistance evaluation includes change of apparent tensile strength evaluation
within ±10% and change in weight of ±2% after chemical exposure for 7 days.
[4] Spears LabWaste™ CPVC Corrosive Waste Drainage System consists of Spears LabWaste™ CPVC
Pipe, Spears LabWaste™ CPVC Fittings, and Low VOC Yellow One-Step LW-5 CPVC Solvent
Cement.
|
|||
Drain, Waste, and Vent - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Fittings[1] [2] |
PVC |
SPEARS |
ASTM D2665 |
|
1/16 Bend (P324-xxx)§ |
|||
| 1 1/2" | 10" | 12" | 2" |
| 3" | 4" | 6" | 8" |
|
1/16 Bend (P326-xxx)§ |
|||
| 1 1/2" | 10" | 12" | 2" |
| 3" | 4" | 6" | 8" |
|
1/4 Bend (P300-xxx)§ |
|||
| 1 1/2" | 10" | 12" | 2" |
| 3" | 4" | 6" | 8" |
|
1/4 Bend (P302-xxx)§ |
|||
| 1 1/2" | 10" | 12" | 2" |
| 3" | 4" | 6" | 8" |
|
1/4 Bend (P303-xxx)§ |
|||
| 3" x 3" x 2" | |||
|
1/4 Bend (P304-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
|
1/4 Bend (P309-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
|
1/4 Bend (P310-xxx)§ |
|||
| 3" x 3" x 2" | |||
|
1/4 Blend (P307-xxx)§ |
|||
| 3" x 3" x 2" | |||
|
1/6 Bend (P319-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
| 6" | |||
|
1/6 Bend (P320-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
| 6" | |||
|
1/8 Bend (P321-xxx)§ |
|||
| 1 1/2" | 1 1/4" | 10" | 12" |
| 2" | 3" | 4" | 6" |
| 8" | |||
|
1/8 Bend (P323-xxx)§ |
|||
| 1 1/2" | 10" | 12" | 2" |
| 3" | 4" | 6" | 8" |
|
2-Way Clean Out (P448-xxx)§ |
|||
| 3" | 4" | ||
|
90° Vent Elbow (P331-xxx)§ |
|||
| 1 1/2" | 10" | 12" | 2" |
| 3" | 4" | 6" | 8" |
|
90° Vent Elbow (P333-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
|
Adapter Bushing (P118-xxx)§ |
|||
| 3" | 4" | ||
|
Bushing (P107-xxx)§ |
|||
| 10" x 8" | 12" x 10" | 2" x 1 1/2" | 3" x 1 1/2" |
| 3" x 2" | 4" x 2" | 4" x 3" | 6" x 4" |
| 8" x 4" | 8" x 6" | ||
|
Cap (P116-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
| 6" | 8" | ||
|
Clean Out Adapter (P105-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
| 6" | 8" | ||
|
Clean Out Adapter (P105H-xxx)§ |
|||
| 4" | 6" | 8" | |
|
Clean Out Adapter (P105X-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
| 6" | 8" | ||
|
Clean Out Plug (P106-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
| 6" | 8" | ||
|
Clean Out Plug (P110-xxx)§ |
|||
| 1 1/2" | 2 1/2" | 2" | 3" |
| 4" | 6" | ||
|
Clean Out Tee (P445-xxx)§ |
|||
| 1 1/2" | 10" | 12" | 2" |
| 3" | 4" | 6" | 8" |
|
Cleanout Tee w/Plug (P444X-xxx)§ |
|||
| 1 1/2" | 10" x 8" | 12" x 8" | 2" |
| 3" | 4" | 6" | 8" |
|
Closet Bend (P329-xxx)§ |
|||
| 3" x 4" | |||
|
Closet Bend (P330-xxx)§ |
|||
| 3" x 4" | |||
|
Closet Bend (P330X-xxx)§ |
|||
| 3" x 4" | |||
|
Closet Flange (P800-xxx)§ |
|||
| 4" x 3" | 4" x 4" | ||
|
Closet Flange (P800G-xxx)§ |
|||
| 4" x 4" | |||
|
Closet Flange (P800S-xxx)§ |
|||
| 4" x 3" | |||
|
Closet Flange (P801-xxx)§ |
|||
| 4" x 3" | |||
|
Closet Flange (P811-xxx)§ |
|||
| 4" | 4" x 3" | ||
|
Closet Flange (P811KO-xxx)§ |
|||
| 4" | 4" x 3" | ||
|
Closet Flange (P812-xxx)§ |
|||
| 4" | 4" x 3" | ||
|
Closet Flange (P820-xxx) |
|||
| 4" x 3" | |||
|
Combination Wye (P501-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
|
Combination Wye (P502-xxx)§ |
|||
| 2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" |
| 4" x 4" x 3" | |||
|
Combination Wye (P503-xxx)§ |
|||
| 3" | 4" | 6" | 8" |
|
Coupling (P100-xxx)§ |
|||
| 1 1/2" | 1 1/4" | 10" | 12" |
| 2" | 3" | 4" | 6" |
| 8" | |||
|
Coupling (P102-xxx)§ |
|||
| 2" x 1 1/2" | 3" x 1 1/2" | 3" x 2" | 4" x 2" |
| 4" x 3" | 6" x 4" | ||
|
Coupling (P130-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
| 6" | 8" | ||
|
Double 1/4 Bend (P327-xxx)§ |
|||
| 1 1/2" | 2" | 2" x 1 1/2" x 1 1/2" | 3" |
| 4" | |||
|
Double Fixture Fitting (P500-xxx)§ |
|||
| 2" | 2" x 1 1/2" x 1 1/2" x 1 1/2" | 2" x 2" x 1 1/2" x 1 1/2" | 3" |
| 3" x 2" x 3" x 3" | |||
|
Double Sanitary Tee (P428-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
| 6" | 8" | ||
|
Double Sanitary Tee (P429-xxx)§ |
|||
| 2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" | 4" x 4" x 3" x 3" |
| 6" x 6" x 3" x 3" | 6" x 6" x 4" x 4" | 8" x 8" x 4" x 4" | |
|
Double Wye (P611-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
| 6" | |||
|
Double Wye (P611S-xxx)§ |
|||
| 3" | |||
|
Double Wye (P612-xxx)§ |
|||
| 2" x 2" x 1 1/2" x 1 1/2" | 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 2" x 2" | 4" x 4" x 2" x 2" |
| 4" x 4" x 3" x 3" | 6" x 6" x 4" x 4" | ||
|
Female Adapter (P101-xxx)§ |
|||
| 1 1/2" | 1 1/4" | 2" | 3" |
| 4" | 6" | 8" | |
|
Flush Closet Flange (P815-xxx)§ |
|||
| 4" | |||
|
Flush Closet Flange (P815KO-xxx)§ |
|||
| 4" | |||
|
Hub Adapter (P123R-xxx)§ |
|||
| 3" x 4" | |||
|
Male Adapter (P109-xxx)§ |
|||
| 1 1/2" | 1 1/4" | 2" | 3" |
| 4" | 6" | ||
|
No Hub Adapter (P119-xxx)§ |
|||
| 1 1/2" | 2" | 2" x 1 1/2" | 3" |
| 4" | 4" x 3" | ||
|
P-Trap (707X-xxx)§ |
|||
| 1 1/2" | 2" | ||
|
P-Trap (708P-xxx)§ |
|||
| 1 1/2" | 2" | ||
|
P-Trap (708X-xxx)§ |
|||
| 1 1/2" | 2" | ||
|
P-Trap (P706-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
|
P-Trap (P709X-xxx)§ |
|||
| 1 1/2" | 2" | ||
|
P-Trap (P711P-xxx)§ |
|||
| 1 1/2" | 1 1/2" x 1 1/4" | ||
|
P-Trap (P711X-xx)§ |
|||
| 1 1/2" | |||
|
Sanitary Tee (P400-xxx)§ |
|||
| 1 1/2" | 1 1/4" | 10" | 12" |
| 2" | 3" | 4" | 6" |
| 8" | |||
|
Sanitary Tee (P401-xxx)§ |
|||
| 2" x 1 1/2" x 1 1/2" | 2" x 1 1/2" x 2" | 2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" |
| 3" x 3" x 2" | 4" x 4" x 2" | 4" x 4" x 3" | |
|
Sanitary Tee (P403-xxx)§ |
|||
| 1 1/2" | 10" | 12" | 2" |
| 3" | 4" | 6" | 8" |
|
Sanitary Tee (P404-xxx)§ |
|||
| 2" x 1 1/2" x 1 1/2" | 2" x 1 1/2" x 2" | 2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" |
| 3" x 3" x 2" | 4" x 4" x 1 1/2" | 4" x 4" x 1 1/2" | 4" x 4" x 3" |
| 4" x 4" x 3" | |||
|
Sanitary Tee (P416-xxx)§ |
|||
| 3" x 3" x 3" x 1 1/2" | 3" x 3" x 3" x 2" | 4" x 4" x 4" x 2" | |
|
Sanitary Tee (P417-xxx)§ |
|||
| 3" x 3" x 3" x 1 1/2" | 3" x 3" x 3" x 2" | ||
|
Sanitary Tee (P418-xxx)§ |
|||
| 3" x 3" x 3" x 1 1/2" x 1 1/2" | 3" x 3" x 3" x 2" x 2" | ||
|
Spigot Adapter, Cast Iron (P122-xxx)§ |
|||
| 3" | 4" | ||
|
Spigot Adapter, Cast Iron (P123-xxx)§ |
|||
| 2" | 3" | 4" | |
|
Tail Piece Adapter (P704P-xxx)§ |
|||
| 1 1/2" | |||
|
Tail Piece Adapter (P704X-xxx)§ |
|||
| 1 1/2" | |||
|
Trap Adapter (P103-xxx)§ |
|||
| 1 1/2" | 1 1/2" x 1 1/4" | 2" | |
|
Trap Adapter (P103P-xxx)§ |
|||
| 1 1/2" | 1 1/2" x 1 1/4" | 2" | |
|
Trap Adapter (P103R-xxx)§ |
|||
| 1 1/2" | |||
|
Trap Adapter (P103X-xxx)§ |
|||
| 1 1/2" | 1 1/2" x 1 1/4" | 2" | |
|
Trap Adapter (P104-xxx)§ |
|||
| 1 1/2" | 1 1/2" x 1 1/4" | 2" | |
|
Trap Adapter (P104P-xxx)§ |
|||
| 1 1/2" | 1 1/2" x 1 1/4" | ||
|
Vent Tee (P441-xxx)§ |
|||
| 1 1/2" | 10" | 12" | 2" |
| 3" | 4" | 6" | 8" |
|
Vent Tee (P442-xxx)§ |
|||
| 10" x 4" | 10" x 6" | 10" x 8" | 12" x 10" |
| 12" x 4" | 12" x 6" | 12" x 8" | 2" x 2" x 1 1/2" |
| 6" x 4" | 8" x 4" | 8" x 6" | |
|
Wye (P600-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
| 6" | 8" | ||
|
Wye (P601-xxx)§ |
|||
| 10" x 10" x 8" | 2" x 1 1/2" x 1 1/2" | 2" x 1 1/2" x 2" | 2" x 2" x 1 1/2" |
| 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 1 1/2" | 4" x 4" x 2" |
| 4" x 4" x 3" | 6" x 6" x 3" | 6" x 6" x 4" | 8" x 8" x 4" |
| 8" x 8" x 6" | |||
|
Wye (P602-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
|
Wye (P603-xxx)§ |
|||
| 2" x 2" x 1 1/2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" | 4" x 4" x 2" |
| 4" x 4" x 3" | |||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. [1] xxx = different size code designation
[2] Fittings to be installed in accordance with the manufacturer's instructions, and the
requirements of the latest edition of the Uniform Plumbing Code.
|
|||
Fittings[2] |
PVC |
Spears |
ASTM D2665 |
|
Cleanout Tee (P445X-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
|
Return Bend (P700-xxx)§ |
|||
| 1 1/2" | 2" | 3" | 4" |
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. [2] Fittings to be installed in accordance with the manufacturer's instructions, and the
requirements of the latest edition of the Uniform Plumbing Code.
|
|||
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Fittings+ [1] [G] |
PVC I-G1 |
SPEARS MANUFACTURING CO. |
ASTM D2464 |
|
45° Ell |
|||
| 819-xxx | |||
|
Bushing |
|||
| 839-xxx | |||
|
Plug |
|||
| 850-xxx | |||
+ Material complies with NSF/ANSI 61 health effects requirements. [1] xxx - different size code designation [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [1] [G] |
PVC I-G1 |
SPEARS MANUFACTURING CO. |
ASTM D2466 |
|
22 1/2° Ell |
|||
| 416-xxx | |||
|
22 1/2° Street Elbow |
|||
| 442-xxx | |||
|
45° Ell |
|||
| 417-xxx | |||
|
45° Street Elbow |
|||
| 427-xxx | |||
|
90° Ell |
|||
| 406-xxx | 407-xxx | 408-xxx | 409-xxx |
| 410-xxx | 412-xxx | ||
|
Adapter |
|||
| 434-xxx | 435-xxx | 436-xxx | |
|
Bushing |
|||
| 439-xxx | |||
|
Cap |
|||
| 447-xxx | 448-xxx | ||
|
Coupling |
|||
| 429-xxx | 430-xxx | ||
|
Cross |
|||
| 420-xxx | |||
|
Plug |
|||
| 449-xxx | 450-xxx | ||
|
Street Tee |
|||
| 444-xxx | |||
|
Tee |
|||
| 401-xxx | 402-xxx | 405-xxx | |
+ Material complies with NSF/ANSI 61 health effects requirements. [1] xxx - different size code designation [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [1] [G] |
PVC I-G1 |
SPEARS MANUFACTURING CO. |
ASTM D2467 |
|
22 1/2° Ell |
|||
| 816-xxx | |||
|
22 1/2° Street Elbow |
|||
| 843-xxx | |||
|
45° Ell |
|||
| 817-xxx | 819-xxx | ||
|
45° Street Elbow |
|||
| 827-xx | |||
|
90° Ell |
|||
| 806-xxx | 809-xxx | ||
|
Adapter |
|||
| 836-xxx | |||
|
Bushing |
|||
| 839-xxx | |||
|
Cap |
|||
| 847-xxx | 848-xxx | ||
|
Coupling |
|||
| 829-xxx | |||
|
Cross |
|||
| 820-xxx | |||
|
Plug |
|||
| 850-xxx | |||
|
Street Tee |
|||
| 844-xxx | |||
|
Tee |
|||
| 801-xxx | |||
+ Material complies with NSF/ANSI 61 health effects requirements. [1] xxx - different size code designation [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [1] [G] |
CPVC 41 |
SPEARS |
ASTM F439 |
|
22 1/2° Ell |
|||
| 4216-xxx | 816-xxx | ||
|
22 1/2° Street Elbow |
|||
| 4242-xxx | 842-xxx | ||
|
45° Ell |
|||
| 4217-xxx | 817-xxx | 819-xxx | |
|
45° Street Elbow |
|||
| 827-xxx | |||
|
90° Ell |
|||
| 4206-xxx | 4209-xxx | 806-xxx | 809-xxx |
|
Adapter |
|||
| 835-xxx | 836-xxx | ||
|
Bushing |
|||
| 4238-xxx | 839-xxx | ||
|
Cap |
|||
| 4247-xxx | 847-xxx | 848-xxx | |
|
Coupling |
|||
| 4229-xxx | 829-xxx | ||
|
Cross |
|||
| 4220-xxx | 820-xxx | ||
|
Plug |
|||
| 850-xxx | |||
|
Street Tee |
|||
| 4244-xxx | 844-xxx | ||
|
Tee |
|||
| 4201-xxx | 801-xxx | ||
+ Material complies with NSF/ANSI 61 health effects requirements. [1] xxx - different size code designation [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [1] [G] |
CPVC 41 |
SPEARS |
ASTM F437 |
|
45° Ell |
|||
| 819-xxx | |||
|
Bushing |
|||
| 839-xxx | |||
|
Plug |
|||
| 850-xxx | |||
+ Material complies with NSF/ANSI 61 health effects requirements. [1] xxx - different size code designation [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [1] [G] |
CPVC 41 |
SPEARS MANUFACTURING CO. |
ASTM F438 |
|
22 1/2° Ell |
|||
| 816-xxx | |||
|
22 1/2° Street Elbow |
|||
| 4242-xxx | 842-xxx | ||
|
45° Ell |
|||
| 417-xxx | 4217-xxx | ||
|
90° Ell |
|||
| 406-xxx | 409-xxx | 4206-xxx | 4209-xxx |
|
Cap |
|||
| 4247-xxx | 447-xxx | ||
|
Coupling |
|||
| 4229-xxx | 429-xxx | ||
|
Cross |
|||
| 4220-xxx | |||
|
Street Tee |
|||
| 4244-xxx | 844-xxx | ||
|
Tee |
|||
| 401-xxx | 4201-xxx | ||
+ Material complies with NSF/ANSI 61 health effects requirements. [1] xxx - different size code designation [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ § [1] [G] |
CPVC 41 |
SPEARS |
ASTM D2846 |
|
45° Ell (soc x soc) |
|||
| 1/2" thru 2" (4117-xxx) | |||
|
45° Street Ell (spg x soc) |
|||
| 1/2" thru 2" (4127-xxx) | |||
|
90° Ell (soc x soc) |
|||
| 1/2" thru 2" (4106-xxx) | |||
|
90° Street Ell (spg x soc) |
|||
| 1/2" thru 2" (4109-xxx) | |||
|
Cap (soc) |
|||
| 1/2" thru 2" (4147-xxx) | |||
|
Coupling (soc x soc) |
|||
| 1/2" thru 2" (4129-xxx) | |||
|
Male Adapter (soc x MIPT) |
|||
| 1/2" thru 2" (4136-xxx) | |||
|
Reducer Bushing (spg x soc) |
|||
| 1/2" thru 2" (4137-xxx) | |||
|
Tee (soc x soc x soc) |
|||
| 1/2" thru 2" (4101-xxx) | |||
|
Transition Bushing (IPS x CTS) |
|||
| 1/2" thru 2" (4140-xxx) | |||
|
Transition Coupling (IPS x CTS) |
|||
| 1/2" thru 2" (4141-xxx) | |||
+ Material complies with NSF/ANSI 61 health effects requirements. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. [1] xxx - different size code designation [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Special Engineered (SE) Products
| Product Type | Material Type | Trade Name | Product Standard |
Fittings[1] |
PVC |
SPEARS |
SE 7992 |
|
Combination Wye (P515-xxx)§ |
|||
| 3" x 3" x 3" x 2" | |||
|
Combination Wye (P516-xxx)§ |
|||
| 3" x 3" x 3" x 2" | |||
|
Combination Wye (P517-xxx)§ |
|||
| 3" x 3" x 3" x 2" x 2" | |||
|
Twin Tee (P447-xxx)§ |
|||
| 3" x 3" x 1 1/2" x 1 1/2" | |||
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. [1] xxx = different size code designation |
|||
Facility : Sylmar, CA
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Fittings+ [G] |
PVC I-G1 |
SPEARS MANUFACTURING CO. |
ASTM D2464 |
|
45° Ell |
|||
| 819-xxx | |||
|
90° Ell |
|||
| 808-xxx | |||
|
Bushing |
|||
| 839-xxx | |||
|
Cap |
|||
| 848-xxx | |||
|
Coupling |
|||
| 830-xxx | |||
|
Plug |
|||
| 850-xxx | |||
|
Tee |
|||
| 805-xxx | |||
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [G] |
PVC I-G1 |
SPEARS MANUFACTURING CO. |
ASTM D2466 |
|
22 1/2° Ell |
|||
| 416-xxx | |||
|
22 1/2° Street Elbow |
|||
| 442-xxx | |||
|
45° Ell |
|||
| 417-xxx | |||
|
45° Street Elbow |
|||
| 427-xxx | |||
|
90° Ell |
|||
| 406-xxx | 407-xxx | 408-xxx | 409-xxx |
| 410-xxx | 412-xxx | ||
|
Adapter |
|||
| 434-xxx | 435-xxx | 436-xxx | |
|
Bushing |
|||
| 439-xxx | |||
|
Cap |
|||
| 447-xxx | 448-xxx | ||
|
Coupling |
|||
| 429-xxx | 430-xxx | ||
|
Cross |
|||
| 420-xxx | |||
|
Manifold Tee |
|||
| 476-xxx | 477-xxx | ||
|
Plug |
|||
| 449-xxx | 450-xxx | ||
|
Street Tee |
|||
| 444-xxx | |||
|
Tee |
|||
| 401-xxx | 402-xxx | 405-xxx | |
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [G] |
PVC I-G1 |
SPEARS MANUFACTURING CO. |
ASTM D2467 |
|
22 1/2° Ell |
|||
| 816-xxx | |||
|
22 1/2° Street Elbow |
|||
| 843-xxx | |||
|
30° Ell |
|||
| 815-xxx | |||
|
45° Ell |
|||
| 817-xxx | 819-xxx | ||
|
45° Street Elbow |
|||
| 827-xxx | |||
|
90° Ell |
|||
| 806-xxx | 807-xxx | 808-xxx | 809-xxx |
|
Adapter |
|||
| 835-xxx | 836-xxx | ||
|
Bushing |
|||
| 839-xxx | |||
|
Cap |
|||
| 847-xxx | 848-xxx | ||
|
Coupling |
|||
| 829-xxx | 830-xxx | ||
|
Cross |
|||
| 820-xxx | |||
|
Plug |
|||
| 849-xxx | 850-xxx | ||
|
Street Tee |
|||
| 844-xxx | |||
|
Tee |
|||
| 801-xxx | 802-xxx | 805-xxx | |
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [G] |
CPVC 41 |
SPEARS |
ASTM F437 |
|
45° Ell |
|||
| 819-xxx | |||
|
90° Ell |
|||
| 808-xxx | |||
|
Bushing |
|||
| 839-xxx | |||
|
Cap |
|||
| 848-xxx | |||
|
Coupling |
|||
| 830-xxx | |||
|
Plug |
|||
| 850-xxx | |||
|
Tee |
|||
| 805-xxx | |||
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [G] |
CPVC 41 |
SPEARS |
ASTM F439 |
|
22 1/2° Ell |
|||
| 4216-xxx | 816-xxx | ||
|
22 1/2° Street Elbow |
|||
| 4242-xxx | 842-xxx | ||
|
30° Ell |
|||
| 815-xxx | |||
|
45° Ell |
|||
| 4217-xxx | 817-xxx | ||
|
45° Street Elbow |
|||
| 827-xxx | |||
|
90° Ell |
|||
| 4206-xxx | 4209-xxx | 806-xxx | 807-xxx |
| 809-xxx | |||
|
Adapter |
|||
| 835-xxx | 836-xxx | ||
|
Cap |
|||
| 4247-xxx | 847-xxx | ||
|
Coupling |
|||
| 4229-xxx | 829-xxx | ||
|
Cross |
|||
| 4220-xxx | 820-xxx | ||
|
Plug |
|||
| 849-xxx | |||
|
Street Tee |
|||
| 4244-xxx | 844-xxx | ||
|
Tee |
|||
| 4201-xxx | 801-xxx | 802-xxx | |
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [G] |
CPVC 41 |
SPEARS MANUFACTURING CO. |
ASTM F438 |
|
22 1/2° Ell |
|||
| 816-xxx | |||
|
22 1/2° Street Elbow |
|||
| 4242-xxx | 842-xxx | ||
|
45° Ell |
|||
| 417-xxx | 4217-xxx | ||
|
90° Ell |
|||
| 406-xxx | 409-xxx | 4206-xxx | 4209-xxx |
|
Cap |
|||
| 4247-xxx | 447-xxx | ||
|
Coupling |
|||
| 4229-xxx | 429-xxx | ||
|
Cross |
|||
| 4220-xxx | |||
|
Street Tee |
|||
| 4244-xxx | 844-xxx | ||
|
Tee |
|||
| 401-xxx | 4201-xxx | ||
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ § [G] |
CPVC 41 |
SPEARS |
ASTM D2846 |
|
45° Ell (S x S) |
|||
| 1/2" thru 2" (4117-xxx) | |||
|
45° Street Ell (Spg x Soc) |
|||
| 1/2" thru 2" (4127-xxx) | |||
|
90° Ell (S x S) |
|||
| 1/2" thru 2" (4106-xxx) | |||
|
90° Street Ell (S x FIPT) |
|||
| 1/2" thru 2" (4109-xxx) | |||
|
Cap (Socket) |
|||
| 1/2" thru 2" (4147-xxx) | |||
|
Coupling (S x S) |
|||
| 1/2" thru 2" (4129-xxx) | |||
|
Male Adapter (Soc x MIPT) |
|||
| 1/2" thru 2" (4136-xxx) | |||
|
Reducer Bushing (Spg x Soc) |
|||
| 1/2" thru 2" (4137-xxx) | |||
|
Tee (S x S x S) |
|||
| 1/2" thru 2" (4101-xxx) | |||
|
Transition Bushing (IPS x CTS) |
|||
| 1/2" thru 2" (4140-xxx) | |||
|
Transition Coupling (IPS x CTS) |
|||
| 1/2" thru 2" (4141-xxx) | |||
+ Material complies with NSF/ANSI 61 health effects requirements. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Reinforced Male Thread+ § [G] |
CPVC 41 |
SPEARS |
ASTM D2846 |
|
Transition Adapter |
|||
| 1/2" thru 2" | |||
+ Material complies with NSF/ANSI 61 health effects requirements. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Stainless Steel+ § [1] [G] |
CPVC 41 |
SPEARS |
ASTM D2846 |
|
Female Adapter |
|||
| 1/2" thru 2" | |||
+ Material complies with NSF/ANSI 61 health effects requirements. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. [1] Reinforced [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Stainless Steel+ § [1] [G] |
CPVC 41 |
SPEARS |
ASTM D2846 |
|
90° Ell |
|||
| 1/2" thru 2" | |||
+ Material complies with NSF/ANSI 61 health effects requirements. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. [1] Reinforced [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Valves% + § [G] |
CPVC 4120 |
SPEARS |
ASTM F1970 |
|
7721-005SR ¼ Turn Angle Supply Stop, MPT x SR FIPT |
|||
| 1/2" | |||
|
7722-005 1/4 Turn Angle Supply Stop, MPT x Socket |
|||
| 1/2" | |||
% Product tested for use in commercial hot water (180°F) applications with a rated pressure of 100 psi. + Material complies with NSF/ANSI 61 health effects requirements. § Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code™. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
NOTE: xxx - different size code designation
Facility : Jerome, ID
Drain, Waste, and Vent - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Fabricated Fittings |
PVC |
SPEARS |
ASTM F1866 |
|
11 1/4° Elbow |
|||
| 3711-xxx | 3911-xxx | ||
|
15° Elbow |
|||
| 3718-xxx | 3918-xxx | ||
|
22 1/2° Elbow |
|||
| 3716-xxx | 3916-xxx | ||
|
30° Elbow |
|||
| 3715-xxx | 3915-xxx | ||
|
45° Elbow |
|||
| 3717-xxx | 3917-xxx | ||
|
45° Street Elbow |
|||
| 3727-xxx | 3927-xxx | ||
|
90° Elbow |
|||
| 3706-xxx | 3906-xxx | ||
|
90° Long Sweep Elbow |
|||
| 3706-xxxLSF | |||
|
90° Street Elbow |
|||
| 3709-xxx | 3909-xxx | ||
|
Cleanout Adapter w/ Plug |
|||
| 3978-xxx | |||
|
Combo Wye |
|||
| 3777-xxx | 3977-xxx | ||
|
Coupling & Reducer Coupling |
|||
| 3729-xxx | 3929-xxx | ||
|
Cross |
|||
| 3720-xxx | 3920-xxx | ||
|
Double Combo Wye |
|||
| 3792-xxx | 3992-xxx | ||
|
Double Sanitary Tee |
|||
| 3791-xxx | 3991-xxx | ||
|
Double Wye |
|||
| 3776-xxx | 3976-xxx | ||
|
Eccentric Reducer Coupling |
|||
| 3729-xxxE | |||
|
IPS x Sewer Adapter |
|||
| 3729-xxxIXS | |||
|
Saddle Tee, FIPT |
|||
| 3764-xxx | |||
|
Sanitary Tee |
|||
| 3790-xxx | 3990-xxx | ||
|
Spigot Plug |
|||
| 3749-xxx | 3949-xxx | ||
|
Stub Saddle Tee, Soc |
|||
| 3765-xxx | |||
|
Tee |
|||
| 3701-xxx | 3901-xxx | ||
|
Wye |
|||
| 3775-xxx | 3975-xxx | ||
NOTE: xxx - different size code designation, 4" through 24"
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Fittings+ [G] |
PVC I-G1 |
SPEARS MANUFACTURING CO. |
ASTM D2464 |
|
45° Ell |
|||
| 819-xxx | |||
|
90° Ell |
|||
| 808-xxx | |||
|
Bushing |
|||
| 839-xxx | |||
|
Cap |
|||
| 848-xxx | |||
|
Coupling |
|||
| 830-xxx | |||
|
Plug |
|||
| 850-xxx | |||
|
Tee |
|||
| 805-xxx | |||
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [G] |
PVC I-G1 |
SPEARS MANUFACTURING CO. |
ASTM D2466 |
|
22 1/2° Ell |
|||
| 416-xxx | |||
|
22 1/2° Street Elbow |
|||
| 442-xxx | |||
|
45° Ell |
|||
| 10" | 12" | ||
|
45° Ell |
|||
| 417-xxx | |||
|
45° Street Elbow |
|||
| 427-xxx | |||
|
90° Ell |
|||
| 10" | 12" | ||
|
90° Ell |
|||
| 406-xxx | 407-xxx | 408-xxx | 409-xxx |
| 410-xxx | 412-xxx | ||
|
Adapter |
|||
| 435-xxx | 436-xxx | ||
|
Bushing |
|||
| 439-xxx | |||
|
Cap |
|||
| 447-xxx | 448-xxx | ||
|
Coupling |
|||
| 429-xxx | 430-xxx | ||
|
Plug |
|||
| 449-xxx | 450-xxx | ||
|
Street Tee |
|||
| 444-xxx | |||
|
Tee |
|||
| 10" | 12" | ||
|
Tee |
|||
| 401-xxx | 402-xxx | 405-xxx | |
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [G] |
PVC I-G1 |
SPEARS MANUFACTURING CO. |
ASTM D2467 |
|
22 1/2° Ell |
|||
| 816-xxx | |||
|
22 1/2° Street Elbow |
|||
| 843-xxx | |||
|
30° Ell |
|||
| 815-xxx | |||
|
45° Ell |
|||
| 817-xxx | 819-xxx | ||
|
45° Street Elbow |
|||
| 827-xxx | |||
|
90° Ell |
|||
| 806-xxx | 807-xxx | 808-xxx | 809-xxx |
|
Adapters |
|||
| 835-xxx | 836-xxx | ||
|
Bushing |
|||
| 839-xxx | |||
|
Cap |
|||
| 847-xxx | 848-xxx | ||
|
Coupling |
|||
| 829-xxx | 830-xxx | ||
|
Plug |
|||
| 849-xxx | 850-xxx | ||
|
Street Tee |
|||
| 844-xxx | |||
|
Tee |
|||
| 801-xxx | 802-xxx | 805-xxx | |
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [G] |
CPVC 41 |
SPEARS |
ASTM F437 |
|
45° Ell |
|||
| 819-xxx | |||
|
90° Ell |
|||
| 808-xxx | |||
|
Bushing |
|||
| 839-xxx | |||
|
Cap |
|||
| 848-xxx | |||
|
Coupling |
|||
| 830-xxx | |||
|
Plug |
|||
| 850-xxx | |||
|
Tee |
|||
| 805-xxx | |||
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [G] |
CPVC 41 |
SPEARS |
ASTM F439 |
|
22 1/2° Ell |
|||
| 4216-xxx | 816-xxx | ||
|
22 1/2° Street Elbow |
|||
| 4242-xxx | 842-xxx | ||
|
30° Ell |
|||
| 815-xxx | |||
|
45° Ell |
|||
| 4217-xxx | 817-xxx | 819-xxx | |
|
45° Street Tee |
|||
| 827-xxx | |||
|
90° Ell |
|||
| 4206-xxx | 4209-xxx | 806-xxx | 807-xxx |
| 808-xxx | 809-xxx | ||
|
Adapter |
|||
| 835-xxx | 836-xxx | ||
|
Bushing |
|||
| 839-xxx | |||
|
Cap |
|||
| 4247-xxx | 847-xxx | 848-xxx | |
|
Coupling |
|||
| 4229-xxx | 829-xxx | 830-xxx | |
|
Plug |
|||
| 4249-xxx | 849-xxx | 850-xxx | |
|
Street Tee |
|||
| 4244-xxx | 844-xxx | ||
|
Tee |
|||
| 4201-xxx | 801-xxx | 802-xxx | 805-xxx |
+ Material complies with NSF/ANSI 61 health effects requirements. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
NOTE: xxx - different size code designation
Number of matching Manufacturers is 1
Number of matching Products is 961
Processing time was 8 seconds