NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| Vanguard Pipe & Fittings Ltd. | |
| 8125 North Fraser Way | |
| Burnaby, BC V5J 5M8 | |
| Canada | |
| 800-747-3739 | |
| 604-431-5024 |
Facility : Burnaby, British Columbia, Canada
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Tubing (PW)+ § [G] |
PE 3608 |
Bruiser |
ASTM D2239 |
| 1/2" – 2" SIDR 7 | |||
| 1/2" – 2" SIDR 9 | |||
| 1/2" – 2" SIDR 11.5 | |||
| 1/2" – 2" SIDR 15 | |||
| 1/2" – 2" SIDR 19 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing+ ¢ [G] |
PE 4710 |
Bruiser |
ASTM D2239 |
| 1/2" - 2" SIDR 7 | |||
| 1/2" - 2" SIDR 9 | |||
| 1/2" - 2" SIDR 11.5 | |||
| 1/2" – 2" SIDR 15 | |||
| 1/2" - 2" SDR 19 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing (PW)+ § [G] |
PE 3608 |
Bruiser |
ASTM D2737 |
| 1/2" – 2" SDR 7.3 | |||
| 1/2" – 2" SDR 9 | |||
| 1/2" – 2" SDR 11 | |||
| 1/2" – 2" SDR 19 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing+ ¢ [G] |
PE 4710 |
Bruiser |
ASTM D2737 |
| 1/2" - 2" SDR 7.3 | |||
| 1/2" - 2" SDR 9 | |||
| 1/2" - 2" SDR 11 | |||
| 1/2" - 2" SDR 19 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing+ ¢ [G] |
PE 4710 |
Bruiser |
ASTM D3035 |
| 1/2" - 2" DR 11 | |||
| 1/2" - 2" DR 19 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing+ § [G] |
PE 3608 |
Bruiser |
AWWA C901 |
| 1/2" – 2" SDR 9 | |||
| 1/2" – 2" SIDR 7 | |||
| 1/2" – 2" SIDR 9 | |||
| 1/2" – 2" SIDR 11.5 | |||
| 1/2" – 2" SIDR 15 | |||
| 1/2" – 2" SIDR 19 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing+ ¢ [G] |
PE 4710 |
Bruiser |
AWWA C901 |
| 1/2" - 2" SDR 9 | |||
| 1/2" - 2" SIDR 7 | |||
| 1/2" - 2" SIDR 9 | |||
| 1/2" - 2" SIDR 11.5 | |||
| 1/2" - 2" SIDR 15 | |||
| 1/2" - 2" SIDR 19 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX 5306 |
CANFLEX™ |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing+ ¢ [G] |
PE 4710 |
Bruiser |
CSA B137.1 |
| 3/4" Series 160 | |||
| 1" Series 125 | |||
| 1 1/4" Series 125 | |||
| 1 1/2" Series 125 | |||
| 2" Series 100 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ @ ^ ~ ¢ § +++ [G] |
PEX |
CANFLEX™ |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX 5306 |
CANPEX™ |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ @ ^ ~ ¢ § +++ [G] |
PEX |
CANPEX™ |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing! # $ ^ ~ ¢ £ § +++ [G] |
PEX 5006 |
CanPEX Barrier |
ASTM F876/F877 |
| 1/4" - 2" SDR 9 | |||
! Orange, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ £ § +++ [G] |
PEX 5006 |
CanPEX Barrier |
ASTM F876/F877 |
| 1/4" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing! # $ ^ ~ ¢ £ § +++ [G] |
PEX |
CanPEX Barrier |
CSA B137.5 |
| 1/4" – 2" SDR 9 | |||
! Orange, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ £ § +++ [G] |
PEX |
CanPEX Barrier |
CSA B137.5 |
| 1/4" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing! # $ ^ ~ ¢ £ § +++ [G] |
PEX 5006 |
CanPEX OXY Barrier |
ASTM F876/F877 |
| 1/4" - 2" SDR 9 | |||
! Orange, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ £ § +++ [G] |
PEX 5006 |
CanPEX OXY Barrier |
ASTM F876/F877 |
| 1/4" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing! # $ ^ ~ ¢ £ § +++ [G] |
PEX |
CanPEX OXY Barrier |
CSA B137.5 |
| 1/4" - 2" SDR 9 | |||
! Orange, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ £ § +++ [G] |
PEX |
CanPEX OXY Barrier |
CSA B137.5 |
| 1/4" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ § µ +++ [G] |
PEX 5306 |
CanPEX Ultra |
ASTM F876/F877 |
| 3/8" – 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ § µ +++ [G] |
PEX |
CanPEX Ultra |
CSA B137.5 |
| 3/8" – 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX 5306 |
CANPEX™ UV |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX |
CANPEX™ UV |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX 5306 |
CANPEX™ UV + |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX |
CANPEX™ UV + |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX 5306 |
CANPEX™ UV + MD |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX |
CANPEX™ UV + MD |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX 5306 |
CANPEX™ UV Plus |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX |
CANPEX™ UV Plus |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX 5306 |
CANPEX™ UV Plus MD |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX |
CANPEX™ UV Plus MD |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX 5306 |
CANPLUMB™ |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ @ ^ ~ ¢ § +++ [G] |
PEX |
CANPLUMB™ |
CSA B137.5 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing! # $ ^ ~ ¢ £ § +++ [G] |
PEX 5006 |
CanRay |
ASTM F876/F877 |
| 1/4" - 2" SDR 9 | |||
! Orange, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ £ § +++ [G] |
PEX 5006 |
CanRay |
ASTM F876/F877 |
| 1/4" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing! # $ ^ ~ ¢ £ § +++ [G] |
PEX |
CanRay |
CSA B137.5 |
| 1/4" – 2" SDR 9 | |||
! Orange, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ £ § +++ [G] |
PEX |
CanRay |
CSA B137.5 |
| 1/4" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing (PW)+ § [G] |
PE 3608 |
Proguard |
ASTM D2239 |
| 1/2" – 2" SIDR 7 | |||
| 1/2" – 2" SIDR 9 | |||
| 1/2" – 2" SIDR 11.5 | |||
| 1/2" – 2" SIDR 15 | |||
| 1/2" – 2" SIDR 19 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing (PW)+ § [G] |
PE 3608 |
Proguard |
ASTM D2737 |
| 1/2" – 2" SDR 9 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing+ § [G] |
PE 3608 |
Proguard |
AWWA C901 |
| 1/2" – 2" SDR 9 | |||
| 1/2" – 2" SIDR 7 | |||
| 1/2" – 2" SIDR 9 | |||
| 1/2" – 2" SIDR 11.5 | |||
| 1/2" – 2" SIDR 15 | |||
| 1/2" – 2" SIDR 19 | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing! # $ ^ ~ ¢ £ § +++ [G] |
PEX 5006 |
RadiantMax |
ASTM F876/F877 |
| 1/4" - 2" SDR 9 | |||
! Orange, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ £ § +++ [G] |
PEX 5006 |
RadiantMax |
ASTM F876/F877 |
| 1/4" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing! # $ ^ ~ ¢ £ § +++ [G] |
PEX |
RadiantMax |
CSA B137.5 |
| 1/4" – 2" SDR 9 | |||
! Orange, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ £ § +++ [G] |
PEX |
RadiantMax |
CSA B137.5 |
| 1/4" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ? @ ^ ~ ¢ § +++ [G] |
PEX 5306 |
Vanex |
ASTM F876/F877 |
| 3/8" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
? The UV material type 5306 is only applicable to the red, white and blue pipe.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing+++ [G] |
PEX 5006 |
Vanex Barrier |
ASTM F876/F877 |
| 1/4" - 2" SDR 9 | |||
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ @ ^ ~ ¢ § +++ [G] |
PEX |
Vanex |
CSA B137.5 |
| 3/8" – 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
@ Blue, natural, red, or white.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing! # $ ^ ~ ¢ £ § +++ [G] |
PEX |
Vanex Barrier |
CSA B137.5 |
| 1/4" – 2" SDR 9 | |||
! Orange, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ £ § +++ [G] |
PEX |
Vanex Barrier |
CSA B137.5 |
| 1/4" - 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing! # $ ^ ~ ¢ £ § +++ [G] |
PEX 5006 |
Vanex Barrier |
ASTM F876/F877 |
| 1/4" - 2" SDR 9 | |||
! Orange, red, and teal green.
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
£ This product is barrier tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ § µ +++ [G] |
PEX 5306 |
Vanex Ultra |
ASTM F876/F877 |
| 3/8" – 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Tubing# $ ^ ~ ¢ § µ +++ [G] |
PEX |
Vanex Ultra |
CSA B137.5 |
| 3/8" – 2" SDR 9 | |||
# Pipe tested as a system using VI fittings manufactured by Vanguard Pipe and Fittings
LTD. Installation/assembly instructions titled “Installation Guidelines for Vanguard
Insert Fittings Systems,” most current edition.
$ Crosslinked polyethylene plastic hot and cold water distribution system and/or hydronic
radiant heating system made in accordance with the current version of the ASTM F877
standard intended for a maximum 100 psi water service and a maximum working temperature
of 180°F. System components consist of tubing and/or fittings. To be installed in
accordance with manufacturer’s instructions and the latest edition of the Uniform
Plumbing Code™.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
~ Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
µ Certified pipe has a black inner layer with a red, white, or blue outer layer.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
2014.
|
|||
Number of matching Manufacturers is 1
Number of matching Products is 91