These NSF Official Listings are current as of Friday, April 05, 2013 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://www.nsf.org/Certified/Plumbing/Listings.asp?Company=4T950&Standard=014&LowLead=Y&



NSF/ANSI 14
Plastics Piping System Components and Related Materials


Click here for a list of End Use Code Designations.

Click on Product Standards or footnote in blue to view the referenced document



 
GTGlobe Industries, Inc. 
350 de Maisonneuve West,
Suite 205 
Montreal, QC H3A 0B4 
Canada 
877-GTGLOBE 
877-484-5623

Facility : MO63102

Chlorine Resistance - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Tubing# + ^ [G]

PEX / AL / PEX (T)

GTGLOBE

NSF Protocol P171
1/2" - 1"

# Certified for black, blue, natural, orange, red, and white.
+ Product complies with ASTM F876/877 and NSF/ANSI Standard 61 health effects requirements.
^ Product also in compliance with test method of ASTM F2023.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

NOTE: End Uses:
      T - Traditional Domestic

Potable Water - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Tubing$ * ^ § +++ [G]

PEX 5006

GTGLOBE

AWWA C904
1/2" - 1 1/2" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Tubing$ * ^ § [G]

PEX 5006

GTPEX

ASTM F876/F877
1/8" - 2 1/2" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
  ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Tubing$ * ˘ § [G]

PEX

GTPEX

CSA B137.5
1/8" - 1" SDR 9

$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Compression Fittings* @ § +++ [G]

MLTPL

GTFIT

ASTM F1281
1/2" - 2 1/2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Fittings tested as a system using GTGLOBE PEX / AL / PEX tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Compression Fittings* @ ˘ § +++ [G]

MLTPL

GTFIT

CSA B137.10
1/2" - 2 1/2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Fittings tested as a system using GTGLOBE PEX / AL / PEX tubing.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Crimp Fittings* ˘ § +++ [G]

MLTPL

GTFIT

CSA B137.5
1/2" - 1"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Crimp Fittings* § +++ [G]

MLTPL

GTFIT

SE 7956
1/2" - 2 1/2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Press Fittings* @ § +++ [G]

MLTPL

GTFIT

ASTM F1281
1/2" - 2 1/2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Fittings tested as a system using GTGLOBE PEX / AL / PEX tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Press Fittings* @ ˘ § +++ [G]

MLTPL

GTFIT

CSA B137.10
1/2" - 2 1/2"

* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
@ Fittings tested as a system using GTGLOBE PEX / AL / PEX tubing.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Tubing# * ˘ § +++ [G]

PEX / AL / PEX

GTGLOBE

CSA B137.10
1/2" - 1"

# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
  manufactured housing.
˘ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
  manufacturer's instructions and the requirements of the latest edition of the Uniform
  Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
    temperatures up to and including Commercial Hot (180° F).
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    


Number of matching Manufacturers is 1
Number of matching Products is 11
Processing time was 0 seconds