These NSF Official Listings are current as of Sunday, February 03, 2013 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://www.nsf.org/Certified/Plumbing/Listings.asp?Company=74630&Standard=014&LowLead=Y&
NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| Rifeng Piping Systems | |
| 5th/F, Rifeng Building | |
| 16 Zumiao Road | |
| Foshan, Guangdong 528000 | |
| China | |
| 86 757 8230 1768 |
Facility : Foshan, China
Chlorine Resistance - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Tubing# + ^ [G] |
PEX / AL / PEX (T) |
Rifeng |
NSF Protocol P171 |
| 1/2" - 1" | |||
# Certified for black, blue, natural, orange, red, and white. + Product complies with ASTM F876/877 and NSF/ANSI Standard 61 health effects requirements. ^ Product also in compliance with test method of ASTM F2023. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
NOTE: End Uses:
T - Traditional Domestic
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Compression Fittings (F1-G)* @ ¢ § +++ [G] |
MLTPL |
R |
CSA B137.10 |
| 1/2" - 2 1/2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
@ Fittings tested as a system using Rifeng PEX / AL / PEX tubing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Crimp Fittings (PF5-G)* ¢ § +++ [G] |
MLTPL |
R |
CSA B137.5 |
| 1/2" - 1" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Crimp Fittings (PF5-G)* § +++ [G] |
MLTPL |
R |
SE 7956 |
| 1/2" - 2 1/2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Press Fittings (F5-G)* @ § +++ [G] |
MLTPL |
R |
ASTM F1281 |
| 1/2" - 2 1/2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
@ Fittings tested as a system using Rifeng PEX / AL / PEX tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Press Fittings (F5-G)* @ ¢ § +++ [G] |
MLTPL |
R |
CSA B137.10 |
| 1/2" - 2 1/2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
@ Fittings tested as a system using Rifeng PEX / AL / PEX tubing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Tubing$ * ^ § +++ [G] |
PEX 5006 |
Rifeng |
ASTM F876/F877 |
| >= 1/8" SDR 9 | |||
$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Tubing$ * ^ § +++ [G] |
PEX 5006 |
Rifeng |
AWWA C904 |
| 1/2" - 1 1/2" SDR 9 | |||
$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Compression Fittings (F1-G)* @ § +++ [G] |
MLTPL |
Rifeng |
ASTM F1281 |
| 1/2" - 2 1/2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
@ Fittings tested as a system using Rifeng PEX / AL / PEX tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Compression Fittings (F1-G)* @ ¢ § +++ [G] |
MLTPL |
Rifeng |
CSA B137.10 |
| 1/2" - 2 1/2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
@ Fittings tested as a system using Rifeng PEX / AL / PEX tubing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Crimp Fittings (PF5-G)* ¢ § +++ [G] |
MLTPL |
Rifeng |
CSA B137.5 |
| 1/2" - 1" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Crimp Fittings (PF5-G)* § +++ [G] |
MLTPL |
Rifeng |
SE 7956 |
| 1/2" - 2 1/2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Press Fittings (F5-G)* @ § +++ [G] |
MLTPL |
Rifeng |
ASTM F1281 |
| 1/2" - 2 1/2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
@ Fittings tested as a system using Rifeng PEX / AL / PEX tubing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Press Fittings (F5-G)* @ ¢ § +++ [G] |
MLTPL |
Rifeng |
CSA B137.10 |
| 1/2" - 2 1/2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
@ Fittings tested as a system using Rifeng PEX / AL / PEX tubing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Tubing$ * ^ ¢ § +++ [G] |
PEX |
Rifeng |
CSA B137.5 |
| >= 1/8" SDR 9 | |||
$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Tubing# * § +++ [G] |
PEX / AL / PEX |
Rifeng |
ASTM F1281 |
| 1/2" - 1" | |||
# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Tubing# * ¢ § +++ [G] |
PEX / AL / PEX |
Rifeng |
CSA B137.10 |
| 1/2" - 1" | |||
# Certified for black, blue, natural, orange, red, and white.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Number of matching Manufacturers is 1
Number of matching Products is 17
Processing time was 0 seconds