NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| The Viking Corporation | |
| 210 North Industrial Park Drive | |
| Hastings, MI 49058 | |
| United States | |
| 877-384-5464 |
Facility : Charlestown, IN
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Fittings+ [G] |
CPVC |
Viking |
ASTM F438 |
|
V5001 Coupling |
|||
| 3/4" | 1" | 1 1/4" | |
|
V5001-G Grooved Adapter |
|||
| 1 1/4" | |||
|
V5001R Coupling |
|||
| 1 1/2" x 3/4" | 1 1/2" x 1 1/4" | 2" x 1" | |
|
V5001R Reducer Coupling |
|||
| 1" x 3/4" | 1 1/4" x 1" | ||
|
V5006 45° Elbow |
|||
| 3/4" | 1" | 1 1/4" | |
|
V5007 90° Elbow |
|||
| 3/4" | 1" | 1 1/4" | |
|
V5007R 90° Reducing Elbow |
|||
| 1" x 3/4" | |||
|
V5011 Tee |
|||
| 3/4" | 1" | 1 1/4" | |
|
V5011R Reducer Tee |
|||
| 1 1/4" x 1" x 3/4" | 1 1/4" x 1" x 1" | 1 1/4" x 1" x 1 1/4" | 1 1/4" x 1 1/4" x 3/4" |
| 1 1/4" x 1 1/4" x 1" | |||
|
V5011R Tee |
|||
| 3/4" x 3/4" x 1" | 1" x 3/4" x 3/4" | 1" x 3/4" x 1" | 1" x 1" x 3/4" |
| 2 1/2" x 2 1/2" x 1" | 2 1/2" x 2 1/2" x 1 1/4" | ||
|
V5018 Reducer Bushing |
|||
| 1" x 3/4" | |||
|
V5019-H Blind Flange |
|||
| 3/4" | 1" | 1 1/4" | |
|
V5035 Cross |
|||
| 3/4" | 1" | 1 1/4" | |
|
V5035R Reducing Cross |
|||
| 1" X 3/4" | |||
|
V5051-H Flange |
|||
| 3/4" | 1" | 1 1/4" | |
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ [G] |
CPVC |
Viking |
ASTM F439 |
|
V5001 Coupling |
|||
| 1 1/2" | 2" | 2 1/2" | 3" |
|
V5001-G Grooved Adapter |
|||
| 1 1/2" | 2" | 2 1/2" | 3" |
|
V5001R Coupling |
|||
| 1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 1" |
| 2" x 1 1/2" | |||
|
V5006 45° Elbow |
|||
| 1 1/2" | 2" | 2 1/2" | 3" |
|
V5007 90° Elbow |
|||
| 1 1/2" | 2" | 2 1/2" | 3" |
|
V5011 Tee |
|||
| 1 1/2" | 2" | 2 1/2" | 3" |
|
V5011R Reducer Tee |
|||
| 1 1/4" x 1 1/4" x 1 1/2" | 1 1/2" x 1 1/4" x 3/4" | 1 1/2" x 1 1/4" x 1" | 1 1/2" x 1 1/2" x 3/4" |
| 1 1/2" x 1 1/2" x 1" | 1 1/2" x 1 1/2" x 2" | 1 1/2" x 1 1/2" x 1 1/4" | 2" x 2" x 3/4" |
| 2" x 2" x 1" | 2" x 2" x 1 1/4" | 2" x 2" x 1 1/2" | |
|
V5011R Tee |
|||
| 2 1/2" x 2 1/2" x 2" | 2 1/2" x 2 1/2" x 1 1/2" | 3" x 3" x 1 1/2" | 3" x 3" x 2" |
| 3" x 3" x 2 1/2" | |||
|
V5017 Cap |
|||
| 1 1/2" | 2" | 2 1/2" | 3" |
|
V5018 Bushing |
|||
| 1 1/2" x 3/4" | 1 1/2" x 1" | 1 1/2" x 1 1/4" | 2" x 3/4" |
| 2" x 1" | 2" x 1 1/4" | 2" x 1 1/2" | 2 1/2" x 1 1/4" |
| 2 1/2" x 1 1/2" | 2 1/2" x 2" | 3" x 2" | 3" x 2 1/2" |
|
V5019-H Blind Flange |
|||
| 1 1/2" | 2" | 2 1/2" | 3" |
|
V5035 Cross |
|||
| 1 1/2" | 2" | 2 1/2" | 3" |
|
V5051-2-A Flange - Van Stone |
|||
| 3" | |||
|
V5051-A Flange - Van Stone |
|||
| 3" | |||
|
V5051-H Flange |
|||
| 1 1/2" | 2" | 2 1/2" | 3" |
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Fittings+ ### [G] |
CPVC |
Viking |
ASTM F1970 |
|
V5033-E-007 Union, Socket |
|||
| 3/4" | 1" | ||
|
V5033-E-011 Union, Socket |
|||
| 3/4" | 1" | ||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
### Product tested for use in hot water (150°F) applications with a rated pressure of 175
psi.
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Fittings+ [G] |
CPVC |
Viking |
SE 8817 |
|
V5001-G-M Grooved Adapter |
|||
| 65 mm - 2 1/2" | |||
+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F. [G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%. |
|||
Number of matching Manufacturers is 1
Number of matching Products is 117