These NSF Official Listings are current as of Friday, April 05, 2013 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://www.nsf.org/Certified/Plumbing/Listings.asp?Company=C0002892&Standard=014&LowLead=Y&



NSF/ANSI 14
Plastics Piping System Components and Related Materials


Click here for a list of End Use Code Designations.

Click on Product Standards or footnote in blue to view the referenced document



 
The Viking Corporation 
210 North Industrial Park Drive
Hastings, MI 49058 
United States 
877-384-5464

Facility : Charlestown, IN

Potable Water - Pipe and Fittings

Product Type Material Type Trade Name Product Standard

Fittings+ [G]

CPVC

Viking

ASTM F438

V5001 Coupling
3/4" 1" 1 1/4"

V5001-G Grooved Adapter
1 1/4"

V5001R Coupling
1 1/2" x 3/4" 1 1/2" x 1 1/4" 2" x 1"

V5001R Reducer Coupling
1" x 3/4" 1 1/4" x 1"

V5006 45° Elbow
3/4" 1" 1 1/4"

V5007 90° Elbow
3/4" 1" 1 1/4"

V5007R 90° Reducing Elbow
1" x 3/4"

V5011 Tee
3/4" 1" 1 1/4"

V5011R Reducer Tee
1 1/4" x 1" x 3/4" 1 1/4" x 1" x 1" 1 1/4" x 1" x 1 1/4" 1 1/4" x 1 1/4" x 3/4"
1 1/4" x 1 1/4" x 1"

V5011R Tee
3/4" x 3/4" x 1" 1" x 3/4" x 3/4" 1" x 3/4" x 1" 1" x 1" x 3/4"
2 1/2" x 2 1/2" x 1" 2 1/2" x 2 1/2" x 1 1/4"

V5018 Reducer Bushing
1" x 3/4"

V5019-H Blind Flange
3/4" 1" 1 1/4"

V5035 Cross
3/4" 1" 1 1/4"

V5035R Reducing Cross
1" X 3/4"

V5051-H Flange
3/4" 1" 1 1/4"

+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Fittings+ [G]

CPVC

Viking

ASTM F439

V5001 Coupling
1 1/2" 2" 2 1/2" 3"

V5001-G Grooved Adapter
1 1/2" 2" 2 1/2" 3"

V5001R Coupling
1 1/2" x 3/4" 1 1/2" x 1" 1 1/2" x 1 1/4" 2" x 1"
2" x 1 1/2"

V5006 45° Elbow
1 1/2" 2" 2 1/2" 3"

V5007 90° Elbow
1 1/2" 2" 2 1/2" 3"

V5011 Tee
1 1/2" 2" 2 1/2" 3"

V5011R Reducer Tee
1 1/4" x 1 1/4" x 1 1/2" 1 1/2" x 1 1/4" x 3/4" 1 1/2" x 1 1/4" x 1" 1 1/2" x 1 1/2" x 3/4"
1 1/2" x 1 1/2" x 1" 1 1/2" x 1 1/2" x 2" 1 1/2" x 1 1/2" x 1 1/4" 2" x 2" x 3/4"
2" x 2" x 1" 2" x 2" x 1 1/4" 2" x 2" x 1 1/2"

V5011R Tee
2 1/2" x 2 1/2" x 2" 2 1/2" x 2 1/2" x 1 1/2" 3" x 3" x 1 1/2" 3" x 3" x 2"
3" x 3" x 2 1/2"

V5017 Cap
1 1/2" 2" 2 1/2" 3"

V5018 Bushing
1 1/2" x 3/4" 1 1/2" x 1" 1 1/2" x 1 1/4" 2" x 3/4"
2" x 1" 2" x 1 1/4" 2" x 1 1/2" 2 1/2" x 1 1/4"
2 1/2" x 1 1/2" 2 1/2" x 2" 3" x 2" 3" x 2 1/2"

V5019-H Blind Flange
1 1/2" 2" 2 1/2" 3"

V5035 Cross
1 1/2" 2" 2 1/2" 3"

V5051-2-A Flange - Van Stone
3"

V5051-A Flange - Van Stone
3"

V5051-H Flange
1 1/2" 2" 2 1/2" 3"

+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Fittings+ ### [G]

CPVC

Viking

ASTM F1970

V5033-E-007 Union, Socket
3/4" 1"

V5033-E-011 Union, Socket
3/4" 1"

+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
### Product tested for use in hot water (150°F) applications with a rated pressure of 175
    psi.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    

Fittings+ [G]

CPVC

Viking

SE 8817

V5001-G-M Grooved Adapter
65 mm - 2 1/2"

+ Material complies with NSF/ANSI 61 health effects requirements when tested at 73° F.
[G] Product complies with NSF/ANSI 61 Annex G, NSF/ANSI 372 and conforms with lead content
    requirements for “lead free” plumbing as defined by California, Vermont, Maryland, and
    Louisiana state laws and the U.S. Safe Drinking Water Act due to take effect January
    2014.

    

    


Number of matching Manufacturers is 1
Number of matching Products is 117
Processing time was 0 seconds