NSF/ANSI 14
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
Plastics Piping System Components and Related Materials
Click here for a list of End Use Code Designations.
Click on Product Standards or footnote in blue to view the referenced document
| Conbraco Industries, Inc. | |
| 701 Matthews-Mint Hill Road | |
| Matthews, NC 28105 | |
| United States | |
| 704-847-9191 |
Facility : Foshan, China
Potable Water - Pipe and Fittings
| Product Type | Material Type | Trade Name | Product Standard |
Crimp Fittings* ¢ § +++ [G] |
MLTPL |
Apollo |
CSA B137.5 |
| 1/2" - 1" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Crimp Fittings* § +++ [G] |
MLTPL |
Apollo |
SE 7956 |
| 1/2" - 2 1/2" | |||
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Tubing$ * ^ § +++ [G] |
PEX 5006 |
Apollo |
ASTM F876/F877 |
| >= 1/8" SDR 9 | |||
$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Tubing$ * ^ § +++ [G] |
PEX 5006 |
Apollo |
AWWA C904 |
| 1/2" - 1 1/2" SDR 9 | |||
$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Tubing$ * ^ ¢ § +++ [G] |
PEX |
Apollo |
CSA B137.5 |
| >= 1/8" SDR 9 | |||
$ Certified for blue, natural, red, and white without oxygen barrier.
* Accepted by NSF for use in residential and commercial construction, including
manufactured housing.
^ Meets the chlorine resistance requirements of ASTM F876 when tested in accordance with
ASTM F2023.
¢ Product is authorized to bear the cNSF and/or the cNSFus Mark.
§ Product is Certified to the Uniform Plumbing Code™. Installation in accordance with the
manufacturer's instructions and the requirements of the latest edition of the Uniform
Plumbing Code™.
+++ Material complies with NSF/ANSI 61 health effects requirements when tested at
temperatures up to and including Commercial Hot (180° F).
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
|||
Number of matching Manufacturers is 1
Number of matching Products is 5