These NSF Official Listings are current as of Sunday, February 03, 2013 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://www.nsf.org/Certified/Pools/Listings.asp?Company=C0079515&Standard=ASME1908&
ANSI/APSP 16 (ASME/ANSI A112.19.8)
Suction Fittings for Use in Swimming Pools, Wading Pools,
Spas, Hot Tubs and Whirlpool Bathtub Appliances
Suction Fittings for Use in Swimming Pools, Wading Pools,
Spas, Hot Tubs and Whirlpool Bathtub Appliances
| Master Spas, Inc. | |
| 6927 Lincoln Parkway | |
| Fort Wayne, IN 46804 | |
| United States | |
| 800-860-7727 | |
| 260-436-9100 | |
| Visit this company's website |
Facility : Fort Wayne, IN
| Suction Fitting Model | Sump Model or Field Type | Orientation (Wall and/or Floor) | Design Flow Rate (GPM) | |
|
Swim Spa Propulsion System |
||||
| WAVE[1] [2] [3] | Master Spa MP Rx 17 (8800) | Wall | [4] | |
| WAVE[1] [2] [3] | Master Spa MP Rx 18 (9700) | Wall | [4] | |
| WAVE XP[1] [2] [3] | Master Spa MP Rx 17 (8800) | Wall | [4] | |
| WAVE XP[1] [2] [3] | Master Spa MP Rx 18 (9700) | Wall | [4] | |
| WAVE XP PRO[1] [2] [3] | Master Spa MP Rx 17 (8800) | Wall | [4] | |
| WAVE XP PRO[1] [2] [3] | Master Spa MP Rx 18 (9700) | Wall | [4] | |
[1] Certified to APSP-16-2011.
[2] This submerged suction outlet cover is Certified only for use as a system in a Master
Spas Swim Spa of the following model(s): Commercial Models - MP Rx 17 (8800) and MP Rx
18 (9700).
[3] Motor controller frequency cannot exceed 68 Hz. The product was tested as a complete
system (Master Spas, Inc. Wave, Wave XP, and Wave XP PRO), along with the manufacturer
supplied motor, submerged suction outlet cover Master Spas P/N X804490) and propeller
(Master Spas P/N X400125 and X400820). This product is not NSF Certified as an
individual submerged suction fitting.
[4] A flow rating for the intake grates was not established due to the open design of the
intake grates and because the Master Spas submerged suction outlet covers were tested as
part of a Master Spas Swim Spa and are only for use only with a Master Spa unit. Please
see the separate NSF Official Listing for the Master Spas Swimspa for more information.
|
||||
NOTE: ANSI/APSP 16-2011 has replaced ANSI/ASME A112.19.8-2007, and addenda A112.19.8a-2008 and
A112.19.8b-2009 which have been withdrawn.
Number of matching Manufacturers is 1
Number of matching Products is 6
Processing time was 0 seconds