These NSF Official Listings are current as of Sunday, February 03, 2013 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://www.nsf.org/Certified/Pools/Listings.asp?Company=C0004137&Standard=050&



NSF/ANSI STANDARD 50
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities



 
NeoTech Aqua Solutions, Inc. 
5893 Oberlin Drive
Suite 104 
San Diego, CA 92121 
United States 
858-571-6590
Visit this company's website

Facility : San Diego, CA

Ultraviolet Light Process Equipment

UVS Series Reactors[1] [2] [3]
UVS222S-35 UVS228S-50 UVS238S-65  
UVS322S-100 UVS328S-150 UVS338S-225  
UVS428S-300 UVS438S-500[4]  

[1] Certified for pool and spa/hot tub end use.
[2] Product has met the requirements of NSF Standard 50, Annex H.1: Disinfection Efficacy
    for the >= 3 log reduction of Enterococcus faecium [ATCC #6569] and Pseudomonas
    aeruginosa [ATCC #27313].  This product is intended for supplemental disinfection and
    should be used with registered or approved disinfection chemicals to impart residual
    concentrations in accordance with state and local regulations. This product has not been
    evaluated to the crytosporidium inactivation requirements of NSF/ANSI 50.
[3] This product has not been Certified by NSF to the requirements of the National
    Electrical Code or electrical product safety standards.
[4] UV system with model designation UVSX438S is NSF Certified for pool and spa end use at a
    maximum working pressure of 50p.s.i.  
    The UVSX438S system type is a stainless steel reactor vessel with a monochromatic UV
    lamp utilizing an in-place chemical cleaning system.
    The UVSX438S has met the NSF/ANSI Standard 50 3-log (or better) cryptosporidium
    inactivation requirements under the following conditions:
    Maximum flow rate of 150gpm at 91-96% or greater UVT when the sensor reading is 7.6
    (mW/cm2) or greater.  
    Maximum flow rate of 251gpm at 95-96% or greater UVT when the sensor reading is 10.0
    (mW/cm2) or greater.  
    Maximum flow rate of 470gpm at 96-98% or greater UVT when the sensor reading is 12.5
    (mW/cm2) or greater.  
    Maximum flow rate of 500gpm at 90-98% or greater UVT when the sensor reading is 12.4
    (mW/cm2) or greater.



Number of matching Manufacturers is 1
Number of matching Products is 8
Processing time was 0 seconds