NSF/ANSI STANDARD 50
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities
Equipment for Swimming Pools, Spas, Hot Tubs
and Other Recreational Water Facilities
| Engineered Treatment Systems LLC | |
| 238 Commercial Drive | |
| Beaver Dam, WI 53916 | |
| United States | |
| 877-885-4628 | |
| 920-885-4628 | |
| Visit this company's website |
Facility : Beaver Dam, WI
Ultraviolet Light Process Equipment
|
UV Generators[1] [2] |
||||||
| ECF-210-4[3] | ECF-215-6[3] | ECF-220-6[3] | ||||
| ECF-220-8[3] | ECF-225-10[3] | ECF-225-8[3] | ||||
| ECF-230-10[3] | ECF-230-12[3] | ECF-230-14[3] | ||||
| ECF-233-12[3] | ECF-233-14[3] | ECF-320-8[3] | ||||
| ECF-325-10[3] | ECF-330-12[3] | ECF-330-14[3] | ||||
| ECF-425-10[3] | ECF-430-12[3] | ECF-430-14[3] | ||||
| ECF-433-14[3] | ECF-530-14[3] | ECP-110-4[3] | ||||
| ECP-113-5[4] [5] | SP-13-4[3] | SP-25-4[3] | ||||
| SP-25-4S[3] | SP-25-6[3] | SP-25-8[3] | ||||
| SP-273-14[3] | SP-273-14S[3] | SP-50-10[3] | ||||
| SP-50-10S[3] | SP-50-12[3] | SP-50-8[3] | ||||
| SP-73-12[3] | SP-73-12S[3] | |||||
[1] Certified for pool and spa/hot tub end use.
[2] This product has not been Certified by NSF to the requirements of the National
Electrical Code or electrical product safety standards.
[3] Product has met the requirements of NSF/ANSI 50, Annex H.1: Disinfection Efficacy for
the >= 3 log reduction of Enterococcus faecium [ATCC #6569] and Pseudomonas aeruginosa
[ATCC #27313]. This product is intended for supplemental disinfection and should be used
with registered or approved disinfection chemicals to impart residual concentrations in
accordance with state and local regulations. This product has not been evaluated to the
cryptosporidium inactivation requirements of NSF/ANSI 50.
[4] Certified for 3 log inactivation of cryptosporidium parvum based on challenge organism
MS2 at 260 gpm at a sensor reading of 192 mW/cm2 with a minimum RED of 31.06 mJ/cm2.
Also Certified for 3 log inactivation of cryptosporidium parvum based on challenge
organism MS2 at 150 gpm at a sensor reading of 196 mW/cm2 with a minimum RED of 40.74
mJ/cm2. Product has also met the requirements of NSF/ANSI 50, Annex H.1: Disinfection
Efficacy for the >= 3 log inactivation of Enterococcus faecium [ATCC #6569] and
Pseudomonas aeruginosa[ATCC #27313]. This product is intended for supplemental
disinfection and should be used with registered or approved disinfection chemicals to
impart residual concentrations in accordance with state and local regulations.
[5] UV system with model designation ECP-113-5 is NSF certified for pool and spa end use at
a maximum working pressure of 50p.s.i.
The ECP-113-5 system type is a stainless steel reactor vessel with a medium pressure UV
lamp utilizing an automatic wiper cleaning system.
The ECP-113-5 has met the NSF/ANSI Standard 50 3-log (or better) cryptosporidium
inactivation requirements under the following conditions:
Maximum flow rate of 50gpm at 79-97% or greater UVT when the sensor reading is 87
(mW/cm2) or greater.
Maximum flow rate of 100gpm at 89-97% or greater UVT when the sensor reading is 162
(mW/cm2) or greater.
Maximum flow rate of 150gpm at 94-97% or greater UVT when the sensor reading is 196
(mW/cm2) or greater.
Maximum flow rate of 260gpm at 94-97% or greater UVT when the sensor reading is 192
(mW/cm2) or greater.
|
||||||