| Ebara International Corporation | |
| 1651 Cedar Line Drive | |
| Rock Hill, SC 29730 | |
| United States | |
| 803-327-5005 | |
| Visit this company's website |
Facility : Sparks, NV
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Pumps[1] [G] |
||||
| 2CDU(A)(B)6(C)(D)(E)[2] | 1¼" x 1" - 1½" x 1" | CLD 23 | MLTPL | |
| 3U(A)(B)(C)(D)(E)(F)(I)[3] [4] | 2" x 1¼" - 3" x 2½" | CLD 23 | MLTPL | |
| 3U4(A)(B)(C)(D)(E)(F)(I)[3] [4] | 2 1/4" x 1 1/2" | CLD 23 | MLTPL | |
| CDU(A)(B)(C)(D)(E)(F)[5] | 1¼" x 1" - 1½" x 1" | CLD 23 | MLTPL | |
| JEU(A)(B)(C)(D)(E)[6] | 1 1/4" x 1" | CLD 23 | MLTPL | |
[1] Sizes are expressed as suction x discharge.
[2] 2CDU Models:
A - Casing Size/Impeller Size
70/206
70/306
120/306
200/506
B - Motor horsepower (hp)
20 - 2
30 - 3
50 - 5
C - Motor Enclosure
T - TEFC (Totally enclosed fan cooled)
D - ODP (Open drip proof)
D - Phase/Volt
3 - Three phase, 230/460 volt
1 - Single phase, 115/230 volt
E - Seal type
C - Carbon/Ceramic/Viton
G - Carbon/Ceramic/NBR
[3] 3U and 3U4 Models:
A - Speed
None - 3450 RPM
4 - 1725 RPM
B - Discharge size
32 - 1 1/4"
40 - 1 1/2"
50 - 2"
65 - 2 1/2"
C - Impeller performance code
125
160
200
"A" and "B" in the model name designate a different design in the impeller.
D - Motor horsepower (hp)
30 - 3
50 - 5
75 - 7.5
100 - 10
150 - 15
200 - 20
250 - 25
300 - 30
E - Motor Enclosure
D - ODP (Open drip proof)
T - TEFC (Totally enclosed fan cooled)
F - Phase
1 - Single phase
3 - Three phase
I - Mechanical Seal Type
C - Carbon/Ceramic/Viton
G - Carbon/Ceramic/NBR
[4] 3U model Certification does not include flange gaskets.
[5] CDU Models:
A - Nominal motor speed
Blank - 3600 rpm
4 - 1750 rpm
B - Casing Size/Impeller Size
70/1
70/3
70/5
120/1
120/3
120/5
200/1
200/3
200/5
C - Motor horsepower (hp)
7 - 0.75
10 - 1
15 - 1.5
20 - 2
30 - 3
D - Motor Enclosure
D - ODP (Open drip proof)
T - TEFC (Totally enclosed fan cooled)
E - Motor Phase
1 - Single phase
3 - Three phase
F - Mechanical Seal Type
C - Carbon/Ceramic/Viton
G - Carbon/Ceramic/NBR
[6] JEU Models:
A - Housing and Impeller Number
806
1506
B - Motor horsepower (hp)
7 - 3/4
10 - 1
15 - 1/2
20- 2
C - Motor Enclosure
D - ODP (Open drip proof)
T - TEFC (Totally enclosed fan cooled)
D - Phase
1 - Single phase
3 - Three phase
E - Seal type
C - Carbon/Ceramic/Viton
G - Carbon/Ceramic/NBR
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
||||
Facility : Rock Hill, SC
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Pumps[1] [G] |
||||
| 2CDU(A)(B)6(C)(D)(E)[2] | 1 1/4"x1"-1 1/2"x1" | CLD 23 | MLTPL | |
| 3U(A)(B)(C)(D)(E)(F)(I)[3] [4] | 2"x1 1/4"-3"x2 1/2" | CLD 23 | MLTPL | |
| 3U4(A)(B)(C)(D)(E)(F)(I)[3] [4] | 2 1/4" x 1 1/2" | CLD 23 | MLTPL | |
| CDU(A)(B)(C)(D)(E)(F)[5] | 1 1/4"x1"-1 1/2"x1" | CLD 23 | MLTPL | |
| JEU(A)(B)(C)(D)(E)[6] | 1 1/4" x 1" | CLD 23 | MLTPL | |
[1] Size is expressed as suction x discharge.
[2] 2CDU Models
A - Casing Size/Impeller Size
70/206
70/306
120/306
200/506
B - Motor horsepower (hp)
20 - 2
30 - 3
50 - 5
C - Motor Enclosure
D - ODP (Open drip proof)
T - TEFC (Totally enclosed fan cooled)
D - Phase/Volt
1 - Single phase, 115/230 volt
3 - Three phase, 230/460 volt
E - Seal type
C - Carbon/Ceramic/Viton
G - Carbon/Ceramic/NBR
[3] 3U and 3U4 Models
A - Speed
None - 3450 RPM
4 - 1725 RPM
B - Discharge size
32 - 1 1/4"
40 - 1 1/2"
50 - 2"
65 - 2 1/2"
C - Impeller performance code
125
160
200
"A" and "B" in the model name designate a different design in the impeller.
D - Motor horsepower (hp)
30 - 3
50 - 5
75 - 7.5
100- 10
150 - 15
200 - 20
250 - 25
300 - 30
E - Motor enclosure
D - ODP (Open drip proof)
T - TEFC (Totally enclosed fan cooled)
F - Phase
1 - Single phase
3 - Three phase
I - Mechanical Seal Type
C - Carbon/Ceramic/Viton
G - Carbon/Ceramic/NBR
4 models indicate a 4 pole motor as opposed to the standard 2 pole motor.
[4] 3U model Certification does not include flange gaskets.
[5] CDU Models
a - Nominal motor speed
Blank - 3600 rpm
4 - 1750 rpm
B - Casing size/impeller size
70/1
70/3
70/5
120/1
120/3
120/5
200/1
200/3
200/5
C - Motor horsepower (hp)
7 - 0.75
10 - 1
15 - 1.5
20 - 2
30 - 3
D - Motor enclosure
D - ODP (Open drip proof)
T - TEFC (Totally enclosed fan cooled)
E - Motor phase
1 - single phase
3 - three phase
F - Mechanical seal type
C - Carbon/Ceramic/Viton
G - Carbon/Ceramic/NBR
[6] JEU Models
A - Housing and impeller number
806
1506
B - Motor horsepower (hp)
7 - 3/4
10 - 1
15 - 1/2
20- 2
C - Motor enclosure
D - ODP (Open drip proof)
T - TEFC (Totally enclosed fan cooled)
D - Phase
1 - Single phase
3 - Three phase
E - Seal type
C - Carbon/Ceramic/Viton
G - Carbon/Ceramic/NBR
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
||||
Facility : Brendola (VI), Italy
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Pumps[1] [2] [G] |
||||
| EVMU32-(W)F (X)(Y)(Z) S | 2 ½" x 2 ½", 4" x 4" | CLD 23 | MLTPL | |
| EVMU45-(W)F (X)(Y)(Z) S | 3" x 3" | CLD 23 | MLTPL | |
| EVMU64-(W)F (X)(Y)(Z) S | 2 ½" x 2 ½", 4" x 4" | CLD 23 | MLTPL | |
| EVMUL32-(W)(R) F (X)(Y)(Z) S | 2 1/2" x 2 1/2" | CLD 23 | MLTPL | |
| EVMUL45-(W)(R) F (X)(Y)(Z) S | 3" x 3" | CLD 23 | MLTPL | |
| EVMUL64-(W)(R) F (X)(Y)(Z) S | 4" x 4" | CLD 23 | MLTPL | |
[1] Size is expressed as suction end x discharge end.
[2] W - Number of impellers
1-18
R - Number of reduced diameter impellers (32, 45, and 64 models only)
0-18
X - Horsepower of motor
0050 - 1/2HP
0075 - 3/4HP
0100 - 1.0HP
0150 - 1.5HP
0200 - 2.0 HP
0300 - 3.0 HP
0500 - 5.0 HP
0750 - 7.5 HP
1000 - 10 HP
1500 - 15 HP
2000 - 20 HP
2500 - 25 HP
3000 - 30 HP
4000 - 40 HP
5000 - 50 HP
Y - Motor type
D - Open drip proof (ODP)
T - Totally enclosed fan cooled (TEFC)
Z - Motor phase
1 - Single phase
3 - Three phase
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
||||
Facility : Cles (TN), Italy
Mechanical Devices
| Water | Water | |||
| Contact | Contact | |||
| Trade Designation | Size | Temp | Material | |
|
Pumps[1] [2] [G] |
||||
| EVMU10-(W) F (X)(Y)(Z) S | 2" x 2" | CLD 23 | MLTPL | |
| EVMU18-(W) F (X)(Y)(Z) S | 2" x 2" | CLD 23 | MLTPL | |
| EVMU3-(W) F (X)(Y)(Z) S | 2 1/2" x 2 1/2" | CLD 23 | MLTPL | |
| EVMU5-(W) F (X)(Y)(Z) S | 1 1/4" x 1 1/4" | CLD 23 | MLTPL | |
| EVMUL10-(W) F (X)(Y)(Z) S | 2" x 2" | CLD 23 | MLTPL | |
| EVMUL18-(W) F (X)(Y)(Z) S | 2" x 2" | CLD 23 | MLTPL | |
| EVMUL3-(W) F (X)(Y)(Z) S | 1 1/4" x 1 1/4" | CLD 23 | MLTPL | |
| EVMUL5-(W) F (X)(Y)(Z) S | 1 1/4" x 1 1/4" | CLD 23 | MLTPL | |
[1] Size is expressed as suction end x discharge end.
[2] W - Number of impellers
1 - 18
X - Horsepower of motor
0050 - 1/2 HP
0075 - 3/4 HP
0100 - 1.0 HP
0150 - 1.5 HP
0200 - 2.0 HP
0300 - 3.0 HP
0500 - 5.0 HP
0750 - 7.5 HP
1000 - 10 HP
1500 - 15 HP
2000 - 20 HP
2500 - 25 HP
3000 - 30 HP
4000 - 40 HP
5000 - 50 HP
Y - Motor Type
D - Open Drip Proof (ODP)
T - Totally Enclosed Fan Cooled (TEFC)
Z - Motor phase
1 - Single phase
3 - Three phase
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's
Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.
|
||||
Number of matching Manufacturers is 1
Number of matching Products is 24
Processing time was 0 seconds