NSF/ANSI STANDARD 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing.  Click here for a list of Abbreviations used in these Listings.


 
Kerick Valve, Inc. 
5570 Florida Mining Boulevard South
Suite 503 
Jacksonville, FL 32257 
United States 
904-732-2258
Visit this company's website

Facility : Jacksonville, FL

Mechanical Devices

      Water Water
      Contact Contact
  Trade Designation Size Temp Material

Miscellaneous Process Devices/Components
  PFXXX[3] [G] CLD 23 MLTPL
  PFXXXX[3] [G] CLD 23 MLTPL
  PFXXXXX[3] [G] CLD 23 MLTPL
  PFXXXXXX[3] [G] CLD 23 MLTPL
  SRXX[4] [G] CLD 23 MLTPL

[3] P Series Float: 
    XXX, XXXX, XXXXX, XXXXXX - Size of the floats in inches
[4] P Series Rod: 
    XX - Length of rod in inches
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's 
    Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
    Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.

Valves
  281811P1[2] CLD 23 MLTPL
  281867P1[2] CLD 23 MLTPL
  HTI(A)(B)(C)(D)(E)(F) Float Valves[2] [G] [1] CLD 23 MLTPL
  I(A)(B)(C)(D)(E)(F) Float Valves[2] [G] [1] CLD 23 MLTPL
  M(A)(B)(C)(D)(E)(F) Float Valves[2] [G] [2] CLD 23 MLTPL
  P(I)(J)(K)(L)(M) Valves[2] [5] [G] CLD 23 MLTPL
  VTI(A)(B)(C)(D)(E)(F) Float Valves[2] [G] [1] CLD 23 MLTPL

[1] M, I, HT and VT Series Float Valves: 
    I  - I Series 
    M  - M Series 
    HT - Horizontal Tank 
    VT - Vertical Tank 
    (A) Valve type: 
        A     - Adjustable 
        blank - Non-adjustable 
    (B) Inlet size: 
        25 - 1/4" tubing inlet 
        2P - 1/4" pipe inlet 
        2S - 1/4" short pipe inlet 
        38 - 3/8" tubing inlet 
        3P - 3/8" pipe 
        05 - 1/2" pipe 
        I2 - Index 1/4" tubing 
        B2 - Bayonet 1/4" tubing 
        32 - 3/8" step 1/4" tubing 
        T5 - 1/2" tapped with 1/4" 
    (C) Material: 
        2 - HR 5009 
        7 - Polyfort FPP 1606-11 
        8 - Geon M4110 
    (D) Orifice size: 
        Blank - 0.093 #4 
        1  - .042 
        2  - .052 
        3  - .062 
        4  - .093 
        6  - .125 
        10 - .1719 
        12 - .188 
    (E) Float: 
        Blank - PF154-NT 
        AN - PF152-NT 
        AB - PF152-BK 
        IB - PF1525-BK 
        IN - PF1525-NT
        BN - PF153-NT 
        BB - PF153-BK 
        GB - PF154-BK 
        CN - PF1753-NT 
        CB - PF1753-BK 
        DN - PF222-NT 
        DB - PF222-BK 
        EN - PF224-NT 
        EB - PF224-BK 
        FN - PF1752-NT 
        FB - PF1752-BK 
        NT - Natural 
        BK - Black 
    (F) Arm: 
        Blank - Reg. Arm 
        S    - s-arm 
        IH00 - Hoz 0" drop 
        IH07 - Hoz .75" drop 
        IH12 - Hoz 1.2" drop 
        IH20 - Hoz 2" drop 
        IV01 - Vert 1" drop
[2] For all valves: 
    [2] May represent the following suffixes when present: 
        -316 - 316 grade stainless steel 
        -BMP - Bent pin 
        -R   - Reversed arm 
        -V   - Vertical 
        -P   - Polyfort FPP 1601-11 
        -G   - Geon 4M4110 TRANS 9492 
        -NT  - Natural (P Series only)
        -BK  - Black (P Series only)
[5] P Series Valves: 
    (I) Mount: 
        S - Standard 
        T - Tank 
        X - Extended 
    (J) Inlet size: 
        38  - 3/8" 
        05  - 1/2" 
        75  - .75" 
        100 - 1" 
        125 - 1.25" 
        150 - 1.5" 
    (K) Outlet size: 
        38 - 3/8" 
        05 - 1/2" 
        Blank - Inlet size 
    (L) Orifice size: 
        L   - Low flow 
        S   - Standard flow 
        187 - .187" 
        25  - .25" 
        312 - .312" 
    (M) Trim hardware: 
        S - Stainless
[G] Product also Certified to NSF/ANSI 61, Annex G and is in compliance with California's 
    Health & Safety Code Section 116875 (commonly known as AB1953) and Vermont Act 193.
    Weighted average lead content <=0.25%; Solder and flux lead content <=0.2%.


Number of matching Manufacturers is 1
Number of matching Products is 12
Processing time was 0 seconds