These NSF Official Listings are current as of Friday, April 05, 2013 at 12:15 a.m. Eastern Time. Please contact NSF International to confirm the status of any Listing, report errors, or make suggestions.
Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://www.nsf.org/Certified/pdwe/Listings.asp?
NSF Certification Guideline
Public Drinking Water Equipment Performance
Public Drinking Water Equipment Performance
| Dow Chemical Company (The) | |
| 1803 Building | |
| Midland, MI 48674 | |
| United States | |
| 1-800-FILMTEC | |
| 989-638-6231 | |
| Visit this company's website |
Facility : Zhejiang, China
| Ultrafiltration Devices | |
| DOW IntegraFlo™ DW102-1100[1] | |
| DOW IntegraPac™ IPD-77[2] | |
| DOW IntegraPac™ IPD-77L[2] | |
| DOW IntegraPac™ IPD-77R[2] | |
| SFD-2880 Ultrafiltration Module[2] | |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.49 log, and a minimum LRV of 6.47 log. The maximum Certified filtrate flux
is 70 gfd, which equals a flow rate of 50.2 gpm. Also tested for virus reduction, with
a mean LRV of 2.27 log, and a minimum LRV of 1.94 log.
[2] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 5.90 log, and a minimum LRV of 5.77 log. The maximum Certified filtrate flux
is 70 gfd, which equals a flow rate of 40.3 gpm. Also tested for virus reduction, with
a mean LRV of 2.54 log, and a minimum LRV of 2.37 log.
|
|
| Hyflux Limited | |
| Hyflux Innovation Centre | |
| 80 Bendemeer Road | |
| Singapore 339949 | |
| Singapore | |
| 65 6214 0777 |
Facility : Singapore
| Ultrafiltration Devices[1] | |
| Kristal UF Polymeric Hollow Fibre Membrane K-600ET0820 | |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 5.9 log, and a minimum LRV of 5.2 log. Maximum Certified filtrate flow rate is
129 LPM (34 GPM), and maximum Certified flux is 151 LMH (76 GFD). Also tested for virus
removal efficiency, with a mean LRV of 2.88 log, and a minimum LRV of 2.35 log.
|
|
| NeoTech Aqua Solutions, Inc. | |
| 5893 Oberlin Drive | |
| Suite 104 | |
| San Diego, CA 92121 | |
| United States | |
| 888-718-5040 | |
| 858-571-6590 | |
| Visit this company's website |
Facility : San Diego, CA
| Ultraviolet Reactor Devices[1] | |
| NeoTech Aqua D438™ | |
[1] Certified by NSF as achieving a minimum of 3-log inactivation of Cryptosporidium at
three conditions of sensor readings and flow rates (control set points). The three
control set points determined for a minimum 3-log inactivation of Cryptosporidium are
151 gpm - 7.9 mW/cm2; 251 gpm - 10.4 mW/cm2; and 501 gpm - 12.5 mW/cm2.
|
|
| Qua Group LLC | |
| 10 Guttman Boulevard | |
| Charleroi, PA 15022 | |
| United States | |
| 877-782-7558 | |
| 724-565-5681 | |
| Visit this company's website |
Facility : # 1 India
| Ultrafiltration Devices[1] | |
| Q-SEP 2008 | |
| Q-SEP 3412 | |
| Q-SEP 4508 | |
| Q-SEP 4512 | |
| Q-SEP 6008 | |
[1] Certified by NSF for Cryptosporidium removal efficiency, with a mean log removal value
(LRV) of 6.18 log, and a minimum LRV of 6.14 log. The maximum Certified filtrate flux
is 88.4 gfd.
|
|
Number of matching Manufacturers is 4
Number of matching Products is 12
Processing time was 0 seconds